OVERRIDE FUNCTION

This function is intended to be used to manually override the current operation of the heater, For example; if the heater is in standby mode (i.e. between finishing time and starting time of a Timer), and the Override button is selected, then the heater will begin to operate, and heat the room.

1

To operate the Override simply press the Override button. The Override indicator will flash.

 

AM

Timer 1 Timer 2 Override

PM

 

Set Room

Temp

Time

2

To manually deactivate the Override simply press the Override button again. The Override indicator will go out, and the heater will return to standby mode.

 

AM

Timer 1 Timer 2 Override

PM

 

Set Room

Temp

Time

The heater will continue to operate on Override until the Override button is pressed again, or one of the Timers takes over the operation of the appliance. This means that the Override mode will automatically drop out if a programmed Starting time is reached. The appliance will then return to operating at times programmed into the Timer(s).

USING THE REMOTE CONTROL

To Turn ON or OFF

Remote Control will not turn heater ON if Timer(s) have been selected.

To manually operate when Timer(s) are not

To Change Temperature

To alter the temperature at any time

selected, simply press

ON

while the heater is

the ON or OFF button.

OFF

operating, simply press the “” or “” buttons.

If the Timer(s) have been selected, and the heater is in standby mode, and the OFF button on the Remote Control is pressed, the Timer(s) will be deactivated.

– 18 –

Image 18
Contents RHFE-308 FTR Contents Getting to Know Your NEW RHFE-308FTR LouvreRemote Control OFFControl Panel Layout On / OFFFeatures Economy Mode Filter IndicatorRemote Control Auto ComfortSafety Points Clean with vacuum cleaner, weekly Turning on Operating Your NEW RHFE-308FTRTo Open the Control Panel Turning OFFRoom Temperature Adjustment Child Lock Economy Timer 1 Timer 2 Override FAN Filter Vertical Louvre AdjustmentDo not remove filter when appliance is operating Humidifier TraySetting the Clock Programming the ON/OFF Timers Turn to Next page to Operate the TimersOperating the Timers SET and Forget OperationTime Elapsed from Ignition to Preset Temperature PRE-HEATOverride Function Using the Remote ControlTo Change Temperature To Turn on or OFFCaring for Your NEW RHFE-308FTR Do not USE SolventsPRE-SERVICE Check At IgnitionError Messages Code Displayed Fault RemedyInstallation Instructions Important Safety InstructionsSpecification Location This heater is not designed to be builtSnow Areas Standard Installation of Flue ManifoldFlue Sizes FIT Back Covers Sides onlyFlue Manifold Position Wall Mounting BracketsInstalling the Flue GeneralDimension Terminal Position Distance Positioning the Flue TerminalSleeve and Manifold Installation Method for Standard WallsCheck rubber seal is in place on terminal Fitting Unit AIR Inlet HoseExhaust Pipe & Locking Clamp Forced Flue Heater Extension Kits Names and Numbers of PartsInstalling AN Extension KIT for the RHFE-308 FTR HOW to InstallFlue Extension Kits Air intake hose Hose joint Maximum extendable length Metres less 1m per bend to a max 3 bendsTo prevent water condensation Conversion Fig #2 Fig #3Connecting GAS and Electrical Services Electrical ConnectionTesting Testing UnitFault Finding Procedure GAS Pressure Setting Satisfactory Unsatisfactory Front View Fitting TOP Spacer and Wall Clip Heater is now secured to the wallInstruct Customer on USE of Heater Block Diagram Wiring Diagram RHFE-308FTRDimensions Flue Position Through Wall Specification RHFE-308 FTRPage Service Contact

RHFE-308 FTR specifications

The Rinnai RHFE-308 FTR is an advanced heating appliance designed to deliver efficient and comfortable warmth, especially in residential settings. It has become a popular choice for homeowners seeking reliable heating solutions that also emphasize energy efficiency and sustainability.

One of the standout features of the Rinnai RHFE-308 FTR is its innovative technology known as "Flue Gas Heat Recovery." This technology allows the heater to utilize the heat generated by combustion to enhance the overall efficiency of the unit. By capturing and repurposing flue gases, the RHFE-308 FTR can provide superior heating performance while minimizing energy waste, making it an environmentally friendly option.

The unit is equipped with a powerful burner system that generates impressive heat output while maintaining low emissions. This not only ensures effective heating but also complies with stringent environmental regulations, contributing to a cleaner atmosphere. Additionally, the Rinnai RHFE-308 FTR is designed to operate quietly, allowing homeowners to enjoy a warm and peaceful environment.

Ease of use is another appealing characteristic of the RHFE-308 FTR. It features a user-friendly control panel, which allows for precise temperature adjustments. Homeowners can set their desired comfort level with just a few simple clicks. This model also includes programmable timer options, enabling users to schedule heating times that align with their daily routines, further enhancing convenience and energy savings.

The compact and sleek design of the RHFE-308 FTR ensures that it can easily blend into various interior styles without looking out of place. It’s also lightweight, making installation straightforward for both professional technicians and savvy DIY enthusiasts. The unit’s construction emphasizes durability, featuring high-quality materials that ensure longevity and reliable performance over time.

Safety is a paramount consideration in the design of the Rinnai RHFE-308 FTR. It comes with multiple safety features, such as overheat protection and a child safety lock, providing peace of mind for families.

Overall, the Rinnai RHFE-308 FTR stands out as a versatile and efficient heating solution. With its advanced technology, user-friendly features, and emphasis on safety, it offers a comfortable and reliable heating experience for modern homes.