Rinnai RHFE-308 FTR user manual Check rubber seal is in place on terminal

Page 30

SLEEVE AND MANIFOLD INSTALLATION

METHOD FOR STANDARD WALLS

5. Check rubber seal is in place on terminal.

Terminal seal

 

 

(Add "weather board"

* For weather board walls, add spare rubber

seal here)

seal provided to compensate for weatherboard

 

angle.

 

6. Installation of Terminal

"TOP" mark "A"

Label

From outside, insert terminal into sleeve with the “A” mark at the top. Left hand side fixing tie is marked “LEFT” (from inside).

 

Fixing Tie

Terminal

 

 

 

 

 

7. Attaching Ties

Cut (leave 20mm free)

 

 

 

Pull hard on left and right hand side ties, clip

 

 

ties over lugs inside sleeve. You should be

Pull hard

 

able to pull ties 2 or 3 slots past the starting

 

 

point. Cut the ties, leaving about 20mm past

Fixing tie

 

the lugs. Bend ties so they are parallel with the

 

Lug

Terminal

wall.

 

Sleeve

 

 

 

 

 

 

8. Insert Inner Connection Assembly. Push

Top Mark

 

assembly into the terminal tube, make sure

 

Screw

 

“TOP” mark is uppermost. Fix with 3 screws

 

 

 

provided.

 

 

 

lnner

 

 

Connections

 

9. Manifold can still be turned after attaching.

Outlet

Rubber cap

Inlet

– 30 –

Image 30
Contents RHFE-308 FTR Contents Getting to Know Your NEW RHFE-308FTR LouvreRemote Control OFFControl Panel Layout On / OFFFeatures Economy Mode Filter IndicatorRemote Control Auto ComfortSafety Points Clean with vacuum cleaner, weekly Turning on Operating Your NEW RHFE-308FTRTo Open the Control Panel Turning OFFRoom Temperature Adjustment Child Lock Economy Timer 1 Timer 2 Override FAN Filter Vertical Louvre AdjustmentDo not remove filter when appliance is operating Humidifier TraySetting the Clock Programming the ON/OFF Timers Turn to Next page to Operate the TimersOperating the Timers SET and Forget OperationTime Elapsed from Ignition to Preset Temperature PRE-HEATOverride Function Using the Remote ControlTo Change Temperature To Turn on or OFFCaring for Your NEW RHFE-308FTR Do not USE SolventsPRE-SERVICE Check At IgnitionError Messages Code Displayed Fault RemedyInstallation Instructions Important Safety InstructionsSpecification Location This heater is not designed to be builtSnow Areas Standard Installation of Flue ManifoldFlue Sizes FIT Back Covers Sides onlyFlue Manifold Position Wall Mounting BracketsInstalling the Flue GeneralDimension Terminal Position Distance Positioning the Flue TerminalSleeve and Manifold Installation Method for Standard WallsCheck rubber seal is in place on terminal Fitting Unit AIR Inlet HoseExhaust Pipe & Locking Clamp Forced Flue Heater Extension Kits Names and Numbers of PartsInstalling AN Extension KIT for the RHFE-308 FTR HOW to InstallFlue Extension Kits Air intake hose Hose joint Maximum extendable length Metres less 1m per bend to a max 3 bendsTo prevent water condensation Conversion Fig #2 Fig #3Connecting GAS and Electrical Services Electrical ConnectionTesting Testing UnitFault Finding Procedure GAS Pressure Setting Satisfactory Unsatisfactory Front View Fitting TOP Spacer and Wall Clip Heater is now secured to the wallInstruct Customer on USE of Heater Block Diagram Wiring Diagram RHFE-308FTRDimensions Flue Position Through Wall Specification RHFE-308 FTRPage Service Contact

RHFE-308 FTR specifications

The Rinnai RHFE-308 FTR is an advanced heating appliance designed to deliver efficient and comfortable warmth, especially in residential settings. It has become a popular choice for homeowners seeking reliable heating solutions that also emphasize energy efficiency and sustainability.

One of the standout features of the Rinnai RHFE-308 FTR is its innovative technology known as "Flue Gas Heat Recovery." This technology allows the heater to utilize the heat generated by combustion to enhance the overall efficiency of the unit. By capturing and repurposing flue gases, the RHFE-308 FTR can provide superior heating performance while minimizing energy waste, making it an environmentally friendly option.

The unit is equipped with a powerful burner system that generates impressive heat output while maintaining low emissions. This not only ensures effective heating but also complies with stringent environmental regulations, contributing to a cleaner atmosphere. Additionally, the Rinnai RHFE-308 FTR is designed to operate quietly, allowing homeowners to enjoy a warm and peaceful environment.

Ease of use is another appealing characteristic of the RHFE-308 FTR. It features a user-friendly control panel, which allows for precise temperature adjustments. Homeowners can set their desired comfort level with just a few simple clicks. This model also includes programmable timer options, enabling users to schedule heating times that align with their daily routines, further enhancing convenience and energy savings.

The compact and sleek design of the RHFE-308 FTR ensures that it can easily blend into various interior styles without looking out of place. It’s also lightweight, making installation straightforward for both professional technicians and savvy DIY enthusiasts. The unit’s construction emphasizes durability, featuring high-quality materials that ensure longevity and reliable performance over time.

Safety is a paramount consideration in the design of the Rinnai RHFE-308 FTR. It comes with multiple safety features, such as overheat protection and a child safety lock, providing peace of mind for families.

Overall, the Rinnai RHFE-308 FTR stands out as a versatile and efficient heating solution. With its advanced technology, user-friendly features, and emphasis on safety, it offers a comfortable and reliable heating experience for modern homes.