Rinnai RHFE-308 FTR user manual FAN Filter, Humidifier Tray, Vertical Louvre Adjustment

Page 13

FAN FILTER

To protect the room air fan from dust particles or lint, a filter is situated at the rear of the appliance. When this filter becomes blocked, the filter indicator will flash to indicate that it should be cleaned. Clean the filter weekly during the heating season to avoid unnecessary strain on the appliance.

Do not remove filter when appliance is operating.

When the filter requires cleaning, clean filter before using the appliance, or whilst the appliance is not operating.

If you do not clean the filter at regular intervals and the filter indicator is allowed to remain flashing, then the appliance will stop and [14] will flash on the Digital Display signifying that the inbuilt safety device has functioned. You must clean the filter before operating the heater again.

HUMIDIFIER TRAY

1

So that you can humidify the air, your Rinnai RHFE-308FTR is fitted with an enamelled tray at the bottom of the heater. If you choose to make use of the humidifier tray, it will need filling about once a day during the heating season. Do not fill the humidifier tray while the heater is running.

To fill the humidifier tray:

Remove the bottom trim panel, below the louvres, by pulling on both sides. Simply pull the tray forward to allow it to be filled with water. The warm air will be humidified as it passes over the water in the tray. Refit the bottom trim panel after filling the tray. The RHFE-308FTR is a very high efficiency appliance, during operation a small amount of condensation is produced in the flue system, this drains into the enamelled humidifier tray.

The humidifier has the benefit (when filled with water) of raising the humidity in the air. With increased humidity, the heater can actually be run at a lower temperature while still maintaining the same level of comfort.

VERTICAL LOUVRE ADJUSTMENT

The warm air flow direction may be altered by inserting a screwdriver or similar tool and gently bending the vertical louvre(s) either to the left or the right.

Note: These louvres are not designed to be adjusted more than 6 times.

– 13 –

Image 13
Contents RHFE-308 FTR Contents Louvre Getting to Know Your NEW RHFE-308FTROFF Remote ControlOn / OFF Control Panel LayoutFeatures Remote Control Filter IndicatorEconomy Mode Auto ComfortSafety Points Clean with vacuum cleaner, weekly To Open the Control Panel Operating Your NEW RHFE-308FTRTurning on Turning OFFRoom Temperature Adjustment Child Lock Economy Timer 1 Timer 2 Override Do not remove filter when appliance is operating Vertical Louvre AdjustmentFAN Filter Humidifier TraySetting the Clock Turn to Next page to Operate the Timers Programming the ON/OFF TimersSET and Forget Operation Operating the TimersPRE-HEAT Time Elapsed from Ignition to Preset TemperatureTo Change Temperature Using the Remote ControlOverride Function To Turn on or OFFDo not USE Solvents Caring for Your NEW RHFE-308FTRAt Ignition PRE-SERVICE CheckCode Displayed Fault Remedy Error MessagesImportant Safety Instructions Installation InstructionsSpecification This heater is not designed to be built LocationFlue Sizes Standard Installation of Flue ManifoldSnow Areas FIT Back Covers Sides onlyWall Mounting Brackets Flue Manifold PositionGeneral Installing the FluePositioning the Flue Terminal Dimension Terminal Position DistanceMethod for Standard Walls Sleeve and Manifold InstallationCheck rubber seal is in place on terminal AIR Inlet Hose Fitting UnitExhaust Pipe & Locking Clamp Names and Numbers of Parts Forced Flue Heater Extension KitsHOW to Install Installing AN Extension KIT for the RHFE-308 FTRFlue Extension Kits Air intake hose Hose joint Metres less 1m per bend to a max 3 bends Maximum extendable lengthTo prevent water condensation Fig #2 Fig #3 ConversionElectrical Connection Connecting GAS and Electrical ServicesTesting Unit TestingFault Finding Procedure GAS Pressure Setting Satisfactory Unsatisfactory Front View Heater is now secured to the wall Fitting TOP Spacer and Wall ClipInstruct Customer on USE of Heater Block Diagram RHFE-308FTR Wiring DiagramDimensions Flue Position Through Wall RHFE-308 FTR SpecificationPage Service Contact

RHFE-308 FTR specifications

The Rinnai RHFE-308 FTR is an advanced heating appliance designed to deliver efficient and comfortable warmth, especially in residential settings. It has become a popular choice for homeowners seeking reliable heating solutions that also emphasize energy efficiency and sustainability.

One of the standout features of the Rinnai RHFE-308 FTR is its innovative technology known as "Flue Gas Heat Recovery." This technology allows the heater to utilize the heat generated by combustion to enhance the overall efficiency of the unit. By capturing and repurposing flue gases, the RHFE-308 FTR can provide superior heating performance while minimizing energy waste, making it an environmentally friendly option.

The unit is equipped with a powerful burner system that generates impressive heat output while maintaining low emissions. This not only ensures effective heating but also complies with stringent environmental regulations, contributing to a cleaner atmosphere. Additionally, the Rinnai RHFE-308 FTR is designed to operate quietly, allowing homeowners to enjoy a warm and peaceful environment.

Ease of use is another appealing characteristic of the RHFE-308 FTR. It features a user-friendly control panel, which allows for precise temperature adjustments. Homeowners can set their desired comfort level with just a few simple clicks. This model also includes programmable timer options, enabling users to schedule heating times that align with their daily routines, further enhancing convenience and energy savings.

The compact and sleek design of the RHFE-308 FTR ensures that it can easily blend into various interior styles without looking out of place. It’s also lightweight, making installation straightforward for both professional technicians and savvy DIY enthusiasts. The unit’s construction emphasizes durability, featuring high-quality materials that ensure longevity and reliable performance over time.

Safety is a paramount consideration in the design of the Rinnai RHFE-308 FTR. It comes with multiple safety features, such as overheat protection and a child safety lock, providing peace of mind for families.

Overall, the Rinnai RHFE-308 FTR stands out as a versatile and efficient heating solution. With its advanced technology, user-friendly features, and emphasis on safety, it offers a comfortable and reliable heating experience for modern homes.