Rinnai EX17C Operating Instructions, Turn the manual valve clockwise To the full OFF position

Page 30

Operating Instructions

FOR YOUR SAFETY READ BEFORE OPERATING

If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand.

B.BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

OPERATING INSTRUCTIONS

STOP! Read the safety information above.

1.Set the thermostat to lowest setting.

2.Turn off all electric power to the appliance using the ON/OFF button on the control panel. Locate the manual gas valve on the back side of the heater.

3. Turn the manual valve clockwise

to the full

OFF position.

 

Manual Valve

 

CLOSE

OPEN

 

 

 

 

 

 

 

 

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information above. If you don’t smell gas, go to the next step.

5. Turn the manual gas valve counterclockwise to the full ON position.

6.Turn on all electric power to the appliance using the ON/OFF button.

7.Set the thermostat to desired setting.

8.Burner is lit when indicator lamp “ON turns red.

9.“ON” indicator and fault code 11, flash when burner fails to ignite.

10.If the appliance will not operate, follow the instructions “To Turn Off Gas To Appliance” and call your service technician or gas supplier. See manual for additional information.

TO TURN OFF GAS TO APPLIANCE

1.

Set the thermostat to lowest setting.

NOTE: The fan will continue to operate until the

2.

Turn off all electric power to the appliance using

appliance is cool. Do not turn the appliance off

by unplugging it from the wall. Keep burner

the ON/OFF button on the control panel.

and control compartment clean.

 

3.Locate the manual gas valve on the side of the

unit. Turn the manual valve clockwise to the full OFF position.

30

Rinnai Corporation EX17C / EX22C Manual

Image 30
Contents EX17C RHFE-434FTA EX22C RHFE-559FTA Table of Contents Consumer Safety Information Safety DefinitionsSafety Behaviors and Practices Specifications Safety FeaturesAppliance Specifications Natural Gas Propane Gas FeaturesFlue Manifolds Name Kit No Fits wallsOperating Instructions Getting to Know your New Heating ApplianceChild Lock Sensible Temperature ControlControl Panel DisplaySetting the timers Setting the ClockSetting and Operating the Timers Operating the timersEconomy Energy Saving Mode Economy Mode InformationOverride Function Humidifier and Air Flow Direction Adjusting Air Flow DirectionSet back Adding Water to the HumidifierCare and Maintenance Before Making a Service Call At IgnitionFault Codes Code Displayed Fault RemedyTroubleshooting Restart FunctionInstallation Instructions General InstructionsGas Connection Clearances to CombustiblesAttach Back Covers Sides Only Dimensions 22.9 582 mm 29.9 760 mm 10.1 in 257 mm 172 mm 85 mmFlue Terminal Clearances SnowDescription Canadian Installations US Installations Installation Parts ‘A’ Flue units onlyConfiguration viewed from behind the appliance Drilling Flue HoleFlue Manifold Installation Flue Manifold Installation Extension Kit Installation IncorrectClearances Installing the Exhaust LineConnecting the Air Intake Hose ClampsExtension Kits and Parts Description FOT-201 FOT-219 FOT-220 FOT-221 FOT-158 FOT-190Connecting the Appliance Slip the securing clip over the sleeve as ShownAdjust Gas Pressure Settings AltitudeFinal Assembly Normal Operating SequenceOperating Instructions Turn the manual valve clockwise To the full OFF positionCut-Away Diagram Wiring Diagram Type 18 AWG wire or its equivalentLadder Diagram EX22CParts List Parts List Parts List Parts List Parts List Parts List Parts List Liste de pieces EX17CSpacer Bracket Support espaceur Combustion Fan Casing Ensemble de carter de ventilateur Conversion Kits Optional / Kits de conversion facultatifs ModèleConsumer Support Warranty InformationLimited Warranty Gas Direct Vent Wall FurnaceHow do I get service? What is not covered? EX17C RHFE-434FTA EX22C RHFE-559FTA Table des matières Sécurité du consommateur Définitions de sécuritéSpécifications de l’appareil SpécificationsDispositifs de sécurité Protection de surintensité Un fusible en verre sur leGaz naturel Gaz propane CaractéristiquesCollecteur de fumée Name Kit No Murs d’ajustementsInstructions d’utilisation Connaissance du nouveau chauffagePanneau de commandes Marche / ArrêtVerrouillage pour les enfants Réglage et utilisation des minuteries Mise à l’heureUtilisation manuelle du chauffage Paramétrage des minuteriesÉconomie Mode de conservation d’énergie Fonction de surpassementAjout deau dans lhumidificateur Programmation de température minimaleHumidificateur et direction du flux d’air Réglage de la direction du flux dairSoins et entretien Avant d’appeler pour de l’aide AtÀ l’allumageIgnitionAutresOther pointsPoints Codes de défauts Code Affiché Défaut RemèdeFonction de redémarrage DépannageInstructions d’installation Instructions généralesConnexion de gaz Dégagement par rapport aux combustiblesFixation des couvercles arrière Côtés seulement Dégagements en sortie de cheminée EX22C ManualRéf Description Installations Canada Installations USA Dégagements en sortie de cheminée SuiteDimensions Pièces d’installation AVent VentKit, Kit,FOT FOT-151Perçage du trou de cheminée Installation du collecteur de fumée Installation du collecteur de fumée Suite Installation du kit d’extension Lien en plastique Rinnai Corporation EX17C / EX22C ManualDégagements Attaches Installation du kit d’extension SuiteInstallation de la conduite d’évacuation Connexion de la conduite d’évacuationInstallation de kit d’extension Kits et pièces d’extensionBranchement de l’appareil Ajustage et Reglage de la Presion de Gas La Séquence normale dOpération LInspection visuelle de FlammeAssemblée finale Instructions de mise en œuvre Lire Avant DE Mettre EN MARCHE, Pour Votre SécuritéSchéma en coupe Schéma de câblage Calibre 18 AWG ou équivalentDiagramme logique Garantie limitée Service à la clientèleInformations de garantie Appareil de chauffage mural au gaz à ventilation directeGarantie limitée Suite Limitation des garantiesRinnai Corporation EX17C / EX22C Manual Rinnai Corporation EX17C / EX22C Manual Rinnai Corporation EX17C / EX22C Manual