Before Making a Service Call

Before making a service call please check the following:

At Ignition:

Heater does not operate.

Is the heater plugged in?

Have the fuses or breaker blown at the fuse box / breaker panel? Is there a power failure?

Is the air filter blocked?

Is anything blocking the outlet for the hot air? Is the flue blocked?

Warm air does not flow when the burner lights.

Smoke or strange smells are produced on the first trial light up after installation.

Sharp clicking noises at ignition

During Combustion:

Clicking noise when the thermostat operates.

Unit is not heating room.

Air filter is blocked or the louvers are blocked or obstructed.

Heater will not re-ignite after overheating.

The fan is started automatically after a short delay.

This is to allow the heat exchanger to warm up, helping to avoid cold draughts.

This is caused by grease or oil and dust on the heat exchanger and will stop after a short time.

This is simply expansion noise from the heat exchanger.

This is the sound of the solenoid gas valves opening and closing.

Is the air filter blocked?

Is the set temperature high enough?

Is the warm air outlet blocked by anything?

Are the doors and windows of the room closed?

Was the appliance correctly sized for the space?

Allow heater to cool, clean air filter, operate again.

Even after unit has cooled down, the heater does not ignite again. Repair is necessary.

Contact a qualified / authorized service provider.

When the unit is turned off.

Convection fan continues to run after turning OFF.

This is to remove the residual heat from the heat exchanger. The fan will stop when the heater cools down.

Other Points:

Steam is discharged from the flue terminal .

High efficiency appliances tend to discharge water vapor on cold days. This is normal.

Unit shuts off without apparent reason.

Check whether filters are blocked. Dirty filters will cause the heater to overheat.

12

Rinnai Corporation EX17C / EX22C Manual

Image 12
Contents EX17C RHFE-434FTA EX22C RHFE-559FTA Table of Contents Consumer Safety Information Safety DefinitionsSafety Behaviors and Practices Specifications Safety FeaturesAppliance Specifications Features Flue ManifoldsNatural Gas Propane Gas Name Kit No Fits wallsOperating Instructions Getting to Know your New Heating ApplianceSensible Temperature Control Control PanelChild Lock DisplaySetting the Clock Setting and Operating the TimersSetting the timers Operating the timersEconomy Energy Saving Mode Economy Mode InformationOverride Function Adjusting Air Flow Direction Set backHumidifier and Air Flow Direction Adding Water to the HumidifierCare and Maintenance Before Making a Service Call At IgnitionFault Codes Code Displayed Fault RemedyTroubleshooting Restart FunctionInstallation Instructions General InstructionsGas Connection Clearances to CombustiblesAttach Back Covers Sides Only Dimensions 22.9 582 mm 29.9 760 mm 10.1 in 257 mm 172 mm 85 mmFlue Terminal Clearances SnowDescription Canadian Installations US Installations Installation Parts ‘A’ Flue units onlyConfiguration viewed from behind the appliance Drilling Flue HoleFlue Manifold Installation Flue Manifold Installation Extension Kit Installation IncorrectInstalling the Exhaust Line Connecting the Air Intake HoseClearances ClampsExtension Kits and Parts Description FOT-201 FOT-219 FOT-220 FOT-221 FOT-158 FOT-190Connecting the Appliance Slip the securing clip over the sleeve as ShownAdjust Gas Pressure Settings AltitudeFinal Assembly Normal Operating SequenceOperating Instructions Turn the manual valve clockwise To the full OFF positionCut-Away Diagram Wiring Diagram Type 18 AWG wire or its equivalentLadder Diagram EX22CParts List Parts List Parts List Parts List Parts List Parts List Parts List Liste de pieces EX17CSpacer Bracket Support espaceur Combustion Fan Casing Ensemble de carter de ventilateur Conversion Kits Optional / Kits de conversion facultatifs ModèleWarranty Information Limited WarrantyConsumer Support Gas Direct Vent Wall FurnaceHow do I get service? What is not covered? EX17C RHFE-434FTA EX22C RHFE-559FTA Table des matières Sécurité du consommateur Définitions de sécuritéSpécifications Dispositifs de sécuritéSpécifications de l’appareil Protection de surintensité Un fusible en verre sur leCaractéristiques Collecteur de fuméeGaz naturel Gaz propane Name Kit No Murs d’ajustementsInstructions d’utilisation Connaissance du nouveau chauffagePanneau de commandes Marche / ArrêtVerrouillage pour les enfants Mise à l’heure Utilisation manuelle du chauffageRéglage et utilisation des minuteries Paramétrage des minuteriesÉconomie Mode de conservation d’énergie Fonction de surpassementProgrammation de température minimale Humidificateur et direction du flux d’airAjout deau dans lhumidificateur Réglage de la direction du flux dairSoins et entretien Avant d’appeler pour de l’aide AtÀ l’allumageIgnitionAutresOther pointsPoints Codes de défauts Code Affiché Défaut RemèdeFonction de redémarrage DépannageInstructions d’installation Instructions généralesConnexion de gaz Dégagement par rapport aux combustiblesFixation des couvercles arrière Côtés seulement Dégagements en sortie de cheminée EX22C ManualRéf Description Installations Canada Installations USA Dégagements en sortie de cheminée SuiteDimensions Pièces d’installation AVent VentKit, Kit,FOT FOT-151Perçage du trou de cheminée Installation du collecteur de fumée Installation du collecteur de fumée Suite Installation du kit d’extension Lien en plastique Rinnai Corporation EX17C / EX22C ManualInstallation du kit d’extension Suite Installation de la conduite d’évacuationDégagements Attaches Connexion de la conduite d’évacuationInstallation de kit d’extension Kits et pièces d’extensionBranchement de l’appareil Ajustage et Reglage de la Presion de Gas La Séquence normale dOpération LInspection visuelle de FlammeAssemblée finale Instructions de mise en œuvre Lire Avant DE Mettre EN MARCHE, Pour Votre SécuritéSchéma en coupe Schéma de câblage Calibre 18 AWG ou équivalentDiagramme logique Service à la clientèle Informations de garantieGarantie limitée Appareil de chauffage mural au gaz à ventilation directeGarantie limitée Suite Limitation des garantiesRinnai Corporation EX17C / EX22C Manual Rinnai Corporation EX17C / EX22C Manual Rinnai Corporation EX17C / EX22C Manual