Controlling Units

The control menu is used when controlling lights and appliances. To enter the control menu, from the top-level display or from the main menu, press the 1 (CTRL) key on the console keypad. OmniPro II will automatically display the first named item in that list. The down arrow key can then be used to scroll through the list, and the ' # ' key is used to select the item. If the specific item number is known, enter the item number followed be the ' # ' key, or scroll up and down among the named items.

After the unit has been selected, press the ' # ' key. The console will display:

Entry Lights (Unit Name) 0=OFF 1=ON 2=DIM 3=BRT

Entry Lights (Unit Name) 4=LVL 5=RMP 9=TIM #=STA

If the selected unit is part of a House Code that is configured to use the Compose Format, the second page of the menu is modified to allow Scene commands. Consequentially, the Level and Ramp Commands are removed from the menu.

Entry

Lights (Unit Name)

4=SCN

9=TIM

#=STA

If selected unit is not capable of dim and bright commands, only a single menu is shown.

Entry Lights (Unit Name) 0=OFF 1=ON 9=TIM #=STA

When you press the 0 (OFF) or 1 (ON) key, the console will beep once, the unit number will be turned off or on, then the display will return to the top-level display.

If the selected unit is part of a Compose lighting group, the 0 (OFF) command will turn off each light in the group for the that unit. The 1 (ON) command will set each light in that group to its last dimmed state.

Dimming and Brightening

To dim a unit, from the control menu, enter the unit number (or scroll to it using the arrow keys), then press the ' # ' key.

Press the 2 key to dim the specified unit. The console display top line will read "UNIT NAME" (unit name being the description of the unit number), and the bottom line will read "STEPS DIMMER (1-9)".

Entry Lights

STEPS DIMMER (1-9):

Press a number, 1 - 9 to indicate how much you want to dim the unit. 1 is a little dimmer, 9 is a lot dimmer. Usually, 2 or 3 steps are best. The console will beep and the light will be dimmed.

To brighten a unit, from the control menu, enter the unit number (or scroll to it using the arrow keys), then press the ' # ' key on the keypad. Press the 4 key to brighten the specified unit.

Press a number, 1 - 9 to indicate how much you want to brighten the unit.

Lighting Level

Press the 4 key to set the desired lighting level of the specified unit. Compose lighting does not respond to the Level command.

Enter a number (0-100) to indicate the lighting level (intensity) of the unit.

LIGHTING LEVEL: 0-100%

0 = No Light / 50 = Light to half intensity / 100 = Light to full intensity

Page 19

Image 27
Contents Home AUTOMATION, INC Copyright 2001-2003 Home Automation, Inc All Rights Reserved Contents Control Telephone Control Page Instructions to Called Party Fire Escape PlanningPage Introduction Underwriters Laboratories UL ListingModel Number Serial Number Console Operation Overall DescriptionDisplay Menus Normal Top-Level DisplayTo silence the beeper, press the * key Error BeepsMain Menu Trouble BeepsConfirmation Beep OmniPro II MaintenanceCancel Areas= OFF Disarming the Security System and Silencing AlarmsSecurity System Operation Arming the Security System= Vacation Using Shortcut Keys= Night DLY Night Delay = NightRestoring Zones = RestoreQuick Arm Bypassing ZonesBurglar ALARM! Zone Name Tripped What To Do When You Come HomeWhat Happens When the Alarm is Activated Burglar Alarm ActivatedFire Alarm Activated Gas Alarm ActivatedEmergency Keys Duress Code Entered or Duress Alarm Activated Alarm ResetAlarm Cancel Trouble Indications CodesMaster Code Manager Code Panic SwitchesDuress Code Area ArmingGoto Area Testing Your System Modules Control CommandsALC Switch Modules ControlUnit Numbers House CodesScrolling Through Names Controlling Units Dimming and BrighteningLighting Level Timed Commands Ramp CommandScene Command Compose All On / Off Status of a UnitInternal Flags Controlling OutputsScenes Leviton Scene ControlButtons HAI RC-Series Thermostats Temperature ControlIf hold mode is On, Hold is shown Programmable Energy Saver Modules PESMs Important Notes Freeze AlarmsHumidity Temperature AlarmsOutdoor Temperature Temperature Control of AppliancesStatus Through Show Events Event LogClear Text Messages MessagesRecord Memo Message Play Memo MessageSay Message Show MessageLog Message Clear MessageSend Message Pro-Link Remote Phones Telephone ControlTelephone Interface In-House PhonesMain Menu Phone Access Denied Remote LockoutTemperature Status Event Phone GOOD-BYE Cancel Repeat Alternate MethodButton TemperatureControl SecurityHeat Setting Cool Setting Timed # Status * Cancel When an HAI Communicating Thermostat is enteredHold # Status Cancel When a Programmable Energy Saver Pesm is enteredMessage Playing and Recording a MessagePlaying and Recording a Custom Phrase Good-Bye Panic Button over the Phone # # # # # #Playing and Recording the Address How the OmniPro II Voice Dialer Works Emergency Dial-OutDigital Dialer Voice DialerPC Access What You Hear If Your OmniPro II Calls YouEntering the Code OmniPro II Ethernet Connections Connecting to Network via PC AccessBuilt-In Ethernet Port Controller IP Address, Port Number, and Encryption Key192.168.0.101 Hub or HAI OmniPro IIRouter Controller Dynamic DNSLocal / Wide Area Network Setup Configuration and Advanced Control Programming ACPSet Up Codes Duress Code Set Up TimeAdvanced Control Programming ACP = Add Programs= Show Programs Otherwise, a help screen is displayed = Delete All Programs Edit ProgramsEdit When 1=TIMED 2=BUTTON Edit Programs WhenTimes Programs Control Unit Event / ALC Switch Press Event Buttons Security Mode Event ButtonsButton and Event Programs Zone Event Buttons Alarm Event Buttons All On/Off Event ButtonsEvent Buttons Message Event Buttons Pro-Link Miscellaneous Event ButtonsEdit Program Command Program Control CommandsProgram Security Commands Program Message Commands Program Button CommandsProgram All On / All Off Commands Program Temperature CommandsProgram Zone Conditions Program Security Mode ConditionsEdit Program Condition Program Control ConditionsProgram Other Conditions Program Time Clock ConditionsSet Up Dial Dial Order Dial Out NumberDial OUT 1 on Dial OUT 1 OFF Dial Out NumbersSet Up Arming Set up Miscellaneous Format Number Description Time Clock 1 on Time Clock 1 OFF House Codes 2-16 X-10 All OffHouse Codes 2-16 X-10 All On Time ClocksLatitude, Longitude, and Time Zone Zone NameDaylight Savings Number Description Controller IP AddressController Port Number Encryption Key Set Up NamesSet Up Address Set Up VoiceFire Escape Planning Underwriters Laboratories RequirementsHome AUTOMATION, INC Powell Street Suite a NEW ORLEANS, LA Federal Communication Commission NoticeIf YOU have Trouble with Your Phones Canadian Industry Canada NoticeOmniPro II Voice Dial-Out Planner Appendix a Dial OUT PlannerPress 9. The system will say Good-bye and hang up Instructions to Called PartyAppendix B Text Description Character Codes Code CharSpace Code Description Appendix C Voice Description CodesLower FaultFall HelloService SafetySwitch TemperatureVCR VolumeVault PhrasePage

II specifications

Home Automation II represents the next evolution in smart home technology, providing users with greater flexibility, convenience, and security through advanced features and integrated systems. This smart home revolution focuses on the seamless interaction of devices and the automation of daily tasks, ultimately enhancing the overall living experience.

One of the key features of Home Automation II is interoperability among a wide range of devices. This enables homeowners to control lights, thermostats, security cameras, and other appliances from a single platform. Whether through smartphones, tablets, or voice-activated assistants, users can easily manage their home environment, monitor energy consumption, and receive real-time notifications. This level of integration not only simplifies operation but also creates a more cohesive smart home ecosystem.

Another significant aspect of Home Automation II is the use of artificial intelligence and machine learning. These technologies learn a homeowner’s habits and preferences, allowing the system to adapt automatically. For example, the thermostat can adjust temperatures based on the time of day and occupancy patterns, while lighting systems can simulate human presence when residents are away. This not only enhances comfort but also contributes to energy efficiency, leading to potential cost savings in utility bills.

Home Automation II offers enhanced security features as well. Smart locks, surveillance cameras, and motion detectors can all be integrated into the home’s network. This allows homeowners to monitor their property remotely, receive security alerts, and even grant access to visitors through mobile apps. Biometric security options, such as facial recognition, are also becoming more common, adding an extra layer of protection.

Furthermore, energy management technologies are a hallmark of Home Automation II. Smart plugs and sensors monitor energy use, providing insights to homeowners about how to reduce consumption. Advanced systems can even automate energy distribution, shifting usage to off-peak hours to alleviate strain on local grids and maximize efficiency.

Finally, voice control has become a prominent feature in Home Automation II, allowing users to operate devices hands-free. Integration with voice-activated platforms like Amazon Alexa, Google Assistant, and Apple Siri adds another layer of convenience, making it easy to control multiple aspects of the home with simple voice commands.

In conclusion, Home Automation II represents a significant step forward in creating intelligent spaces that are responsive to the needs of their users. Through the integration of cutting-edge technologies, enhanced security measures, energy management, and intuitive control options, the concept of a smart home is evolving into a more accessible and efficient reality.