Home Automation II owner manual Latitude, Longitude, and Time Zone, Zone Name, Daylight Savings

Page 74

Latitude, Longitude, and Time Zone

The system automatically calculates the time of sunrise and sunset each day. Sunrise/sunset can be specified as the time a scheduling command is executed, as an enable/disable time, or as a darkness condition on a scheduling command or event button.

To enable the system to properly calculate sunrise and sunset times, you must enter your latitude, location north or south of the equator, longitude, location east or west of the Prime Meridian, and time zone.

These items should be set to the proper values for the location where the OmniPro II is installed. The latitude and longitude for a particular location may be obtained from an almanac or map of the area. These values should be entered to the nearest degree.

The value entered for the time zone is the number of hours difference between local standard time at the OmniPro II location and Greenwich Mean Time. The following values should be used for the standard time zones in North America:

ZONE NAME

4ATLANTIC

5EASTERN

6CENTRAL

7MOUNTAIN

8PACIFIC

9YUKON

10ALASKA-HAWAII

11BERING

The value specified for longitude may be adjusted to correct for areas, such as Nova Scotia, where the local time differs from Greenwich Mean Time by a non-hourly amount. The calculated time of sunrise/sunset will change by four minutes for every degree change in longitude. To cause the calculated sunrise/sunset to occur later, enter a larger value for longitude. Enter a smaller value for longitude to cause the time to occur earlier.

It is not necessary to alter the time zone to compensate for daylight savings time, the OmniPro II will automatically adjust its calculations for sunrise and sunset, and time when daylight savings time begins and ends.

LATITUDE:

30

0-60

LATITUDE N/S:

1

1=NORTH 2=SOUTH

LONGITUDE:

90

0-180

LONGITUDE E/W:

2

1=EAST 2=WEST

TIME ZONE:

6

0-12

Daylight Savings

The OmniPro II automatically calculates the day of daylight savings time each year. It also adjusts the "time of day" each time daylight savings time begins and ends.

To enable the system to properly calculate daylight savings time, a start month, start weekend, end month, and end weekend is set-up at the factory. You may change or disable this function if desired.

DST START MONTH:

4

1-12 0=DISABLE

Page 66

Image 74
Contents Home AUTOMATION, INC Copyright 2001-2003 Home Automation, Inc All Rights Reserved Contents Control Telephone Control Page Fire Escape Planning Instructions to Called PartyPage Model Number Serial Number IntroductionUnderwriters Laboratories UL Listing Overall Description Console OperationNormal Top-Level Display Display MenusTrouble Beeps Error BeepsMain Menu To silence the beeper, press the * keyAreas OmniPro II MaintenanceCancel Confirmation BeepArming the Security System Disarming the Security System and Silencing AlarmsSecurity System Operation = OFF= Night Using Shortcut Keys= Night DLY Night Delay = VacationBypassing Zones = RestoreQuick Arm Restoring ZonesBurglar Alarm Activated What To Do When You Come HomeWhat Happens When the Alarm is Activated Burglar ALARM! Zone Name TrippedEmergency Keys Fire Alarm ActivatedGas Alarm Activated Alarm Cancel Duress Code Entered or Duress Alarm ActivatedAlarm Reset Master Code Trouble IndicationsCodes Area Arming Panic SwitchesDuress Code Manager CodeGoto Area Testing Your System Control Control CommandsALC Switch Modules ModulesHouse Codes Unit NumbersScrolling Through Names Lighting Level Controlling UnitsDimming and Brightening Scene Command Compose Timed CommandsRamp Command Controlling Outputs Status of a UnitInternal Flags All On / OffLeviton Scene Control ScenesButtons Temperature Control HAI RC-Series ThermostatsIf hold mode is On, Hold is shown Programmable Energy Saver Modules PESMs Freeze Alarms Important NotesTemperature Control of Appliances Temperature AlarmsOutdoor Temperature HumidityStatus Through Event Log Show EventsPlay Memo Message MessagesRecord Memo Message Clear Text MessagesClear Message Show MessageLog Message Say MessageSend Message Pro-Link In-House Phones Telephone ControlTelephone Interface Remote PhonesAlternate Method Phone Access Denied Remote LockoutTemperature Status Event Phone GOOD-BYE Cancel Repeat Main MenuSecurity TemperatureControl ButtonWhen a Programmable Energy Saver Pesm is entered When an HAI Communicating Thermostat is enteredHold # Status Cancel Heat Setting Cool Setting Timed # Status * CancelPlaying and Recording a Custom Phrase MessagePlaying and Recording a Message Playing and Recording the Address Good-ByePanic Button over the Phone # # # # # # Voice Dialer Emergency Dial-OutDigital Dialer How the OmniPro II Voice Dialer WorksEntering the Code PC AccessWhat You Hear If Your OmniPro II Calls You Controller IP Address, Port Number, and Encryption Key Connecting to Network via PC AccessBuilt-In Ethernet Port OmniPro II Ethernet ConnectionsDynamic DNS 192.168.0.101 Hub or HAI OmniPro IIRouter ControllerLocal / Wide Area Network Set Up Codes SetupConfiguration and Advanced Control Programming ACP Set Up Time Duress Code= Show Programs Advanced Control Programming ACP= Add Programs Otherwise, a help screen is displayed Edit Programs = Delete All ProgramsTimes Programs Edit When 1=TIMED 2=BUTTONEdit Programs When Button and Event Programs Control Unit Event / ALC Switch Press Event ButtonsSecurity Mode Event Buttons Zone Event Buttons Event Buttons Alarm Event ButtonsAll On/Off Event Buttons Miscellaneous Event Buttons Message Event Buttons Pro-LinkProgram Security Commands Edit Program CommandProgram Control Commands Program Temperature Commands Program Button CommandsProgram All On / All Off Commands Program Message CommandsProgram Control Conditions Program Security Mode ConditionsEdit Program Condition Program Zone ConditionsProgram Time Clock Conditions Program Other ConditionsSet Up Dial Dial Out Numbers Dial Out NumberDial OUT 1 on Dial OUT 1 OFF Dial OrderSet Up Arming Set up Miscellaneous Format Number Description Time Clocks House Codes 2-16 X-10 All OffHouse Codes 2-16 X-10 All On Time Clock 1 on Time Clock 1 OFFDaylight Savings Latitude, Longitude, and Time ZoneZone Name Controller Port Number Number DescriptionController IP Address Set Up Names Encryption KeySet Up Voice Set Up AddressUnderwriters Laboratories Requirements Fire Escape PlanningFederal Communication Commission Notice Home AUTOMATION, INC Powell Street Suite a NEW ORLEANS, LACanadian Industry Canada Notice If YOU have Trouble with Your PhonesAppendix a Dial OUT Planner OmniPro II Voice Dial-Out PlannerInstructions to Called Party Press 9. The system will say Good-bye and hang upSpace Appendix B Text Description Character CodesCode Char Appendix C Voice Description Codes Code DescriptionHello FaultFall LowerTemperature SafetySwitch ServicePhrase VolumeVault VCRPage

II specifications

Home Automation II represents the next evolution in smart home technology, providing users with greater flexibility, convenience, and security through advanced features and integrated systems. This smart home revolution focuses on the seamless interaction of devices and the automation of daily tasks, ultimately enhancing the overall living experience.

One of the key features of Home Automation II is interoperability among a wide range of devices. This enables homeowners to control lights, thermostats, security cameras, and other appliances from a single platform. Whether through smartphones, tablets, or voice-activated assistants, users can easily manage their home environment, monitor energy consumption, and receive real-time notifications. This level of integration not only simplifies operation but also creates a more cohesive smart home ecosystem.

Another significant aspect of Home Automation II is the use of artificial intelligence and machine learning. These technologies learn a homeowner’s habits and preferences, allowing the system to adapt automatically. For example, the thermostat can adjust temperatures based on the time of day and occupancy patterns, while lighting systems can simulate human presence when residents are away. This not only enhances comfort but also contributes to energy efficiency, leading to potential cost savings in utility bills.

Home Automation II offers enhanced security features as well. Smart locks, surveillance cameras, and motion detectors can all be integrated into the home’s network. This allows homeowners to monitor their property remotely, receive security alerts, and even grant access to visitors through mobile apps. Biometric security options, such as facial recognition, are also becoming more common, adding an extra layer of protection.

Furthermore, energy management technologies are a hallmark of Home Automation II. Smart plugs and sensors monitor energy use, providing insights to homeowners about how to reduce consumption. Advanced systems can even automate energy distribution, shifting usage to off-peak hours to alleviate strain on local grids and maximize efficiency.

Finally, voice control has become a prominent feature in Home Automation II, allowing users to operate devices hands-free. Integration with voice-activated platforms like Amazon Alexa, Google Assistant, and Apple Siri adds another layer of convenience, making it easy to control multiple aspects of the home with simple voice commands.

In conclusion, Home Automation II represents a significant step forward in creating intelligent spaces that are responsive to the needs of their users. Through the integration of cutting-edge technologies, enhanced security measures, energy management, and intuitive control options, the concept of a smart home is evolving into a more accessible and efficient reality.