Home Automation II owner manual Status

Page 37

Status

The Status function is used to display the status of various items in the system. To enter the status menu, from the top-level display or the main menu, press the 6 (STATUS) key on the console keypad.

STATUS

1=CTRL 2=ZONE 3=SUN

4=TEST 5=TEMP 6=ENERGY

1 = CTRL (CONTROL UNITS)

The Control Status menu allows you to view and scroll through the status of each control unit. To enter the Unit menu, from the Status menu, press the 1 (CTRL) key in the console keypad. The system will display:

DEN LAMP

STATUS OFF

You may enter a unit number to start displaying the status of that unit, or simply press the down arrow key to scroll through the list of units. The status display is as shown under Control, except that now the arrow keys may be used to continue scrolling between units.

Porch Light

00:24:19

LAST COMMANDED

ON

You can also check the state and (if any) the remaining time duration of any Unit.

At this point, you may press the ' # ' key to control the unit as specified under Controlling Units.

2 = ZONE

The Zone Status menu allows you to view and scroll through the status of each zone input. To enter the Zone menu, from the Status menu, press the 2 (ZONE) key on the console keypad. The system will display:

Front Door

SECURE

ZONE 1

You may enter a zone number to start displaying the status with zone, or simply press the down arrow key to start with the first zone. The arrow keys may be used to continue scrolling between zones. For each zone, the display will show the zone name, the zone number, and the current status of the zone:

3 = SUN (SUNRISE / SUNSET AUTOMATIC CALCULATION)

The system automatically calculates the time of sunrise and sunset each day. From the status menu, press the 3 (SUN) key on the console keypad to display the calculated time of sunrise, sunset, and the outdoor temperature (if outdoor temp sensor installed):

Sunrise:

6:00

AM

Temp

Sunset:

5:58

PM

85

4 = TEST (SYSTEM DIAGNOSTIC TEST)

The diagnostic test performed by the OmniPro II allows you to check the status of the battery, telephone, bell circuit, auxiliary fuse, and security zone loop readings. The display is updated 3 times per second, although the actual readings are taken 10 times per second. To enter the Test menu, from the Status menu, press the 4 (TEST) key on the console keypad.

The first display shows the current battery reading and the phone line status. A battery test is initiated when the status mode is first entered. The new battery reading is updated ten seconds later. The low battery limit is also displayed.

The phone status consists of two parts, separated by a "/". The first part shows the current phone line state:

Page 29

Image 37
Contents Home AUTOMATION, INC Copyright 2001-2003 Home Automation, Inc All Rights Reserved Contents Control Telephone Control Page Instructions to Called Party Fire Escape PlanningPage Underwriters Laboratories UL Listing IntroductionModel Number Serial Number Console Operation Overall DescriptionDisplay Menus Normal Top-Level DisplayMain Menu Error BeepsTrouble Beeps To silence the beeper, press the * keyCancel OmniPro II MaintenanceAreas Confirmation BeepSecurity System Operation Disarming the Security System and Silencing AlarmsArming the Security System = OFF= Night DLY Night Delay Using Shortcut Keys= Night = VacationQuick Arm = RestoreBypassing Zones Restoring ZonesWhat Happens When the Alarm is Activated What To Do When You Come HomeBurglar Alarm Activated Burglar ALARM! Zone Name TrippedGas Alarm Activated Fire Alarm ActivatedEmergency Keys Alarm Reset Duress Code Entered or Duress Alarm ActivatedAlarm Cancel Codes Trouble IndicationsMaster Code Duress Code Panic SwitchesArea Arming Manager CodeGoto Area Testing Your System ALC Switch Modules Control CommandsControl ModulesUnit Numbers House CodesScrolling Through Names Dimming and Brightening Controlling UnitsLighting Level Ramp Command Timed CommandsScene Command Compose Internal Flags Status of a UnitControlling Outputs All On / OffScenes Leviton Scene ControlButtons HAI RC-Series Thermostats Temperature ControlIf hold mode is On, Hold is shown Programmable Energy Saver Modules PESMs Important Notes Freeze AlarmsOutdoor Temperature Temperature AlarmsTemperature Control of Appliances HumidityStatus Through Show Events Event LogRecord Memo Message MessagesPlay Memo Message Clear Text MessagesLog Message Show MessageClear Message Say MessageSend Message Pro-Link Telephone Interface Telephone ControlIn-House Phones Remote PhonesTemperature Status Event Phone GOOD-BYE Cancel Repeat Phone Access Denied Remote LockoutAlternate Method Main MenuControl TemperatureSecurity ButtonHold # Status Cancel When an HAI Communicating Thermostat is enteredWhen a Programmable Energy Saver Pesm is entered Heat Setting Cool Setting Timed # Status * CancelPlaying and Recording a Message MessagePlaying and Recording a Custom Phrase Panic Button over the Phone # # # # # # Good-ByePlaying and Recording the Address Digital Dialer Emergency Dial-OutVoice Dialer How the OmniPro II Voice Dialer WorksWhat You Hear If Your OmniPro II Calls You PC AccessEntering the Code Built-In Ethernet Port Connecting to Network via PC AccessController IP Address, Port Number, and Encryption Key OmniPro II Ethernet Connections192.168.0.101 Hub or HAI OmniPro IIRouter Controller Dynamic DNSLocal / Wide Area Network Configuration and Advanced Control Programming ACP SetupSet Up Codes Duress Code Set Up Time= Add Programs Advanced Control Programming ACP= Show Programs Otherwise, a help screen is displayed = Delete All Programs Edit ProgramsEdit Programs When Edit When 1=TIMED 2=BUTTONTimes Programs Security Mode Event Buttons Control Unit Event / ALC Switch Press Event ButtonsButton and Event Programs Zone Event Buttons All On/Off Event Buttons Alarm Event ButtonsEvent Buttons Message Event Buttons Pro-Link Miscellaneous Event ButtonsProgram Control Commands Edit Program CommandProgram Security Commands Program All On / All Off Commands Program Button CommandsProgram Temperature Commands Program Message CommandsEdit Program Condition Program Security Mode ConditionsProgram Control Conditions Program Zone ConditionsProgram Other Conditions Program Time Clock ConditionsSet Up Dial Dial OUT 1 on Dial OUT 1 OFF Dial Out NumberDial Out Numbers Dial OrderSet Up Arming Set up Miscellaneous Format Number Description House Codes 2-16 X-10 All On House Codes 2-16 X-10 All OffTime Clocks Time Clock 1 on Time Clock 1 OFFZone Name Latitude, Longitude, and Time ZoneDaylight Savings Controller IP Address Number DescriptionController Port Number Encryption Key Set Up NamesSet Up Address Set Up VoiceFire Escape Planning Underwriters Laboratories RequirementsHome AUTOMATION, INC Powell Street Suite a NEW ORLEANS, LA Federal Communication Commission NoticeIf YOU have Trouble with Your Phones Canadian Industry Canada NoticeOmniPro II Voice Dial-Out Planner Appendix a Dial OUT PlannerPress 9. The system will say Good-bye and hang up Instructions to Called PartyCode Char Appendix B Text Description Character CodesSpace Code Description Appendix C Voice Description CodesFall FaultHello LowerSwitch SafetyTemperature ServiceVault VolumePhrase VCRPage

II specifications

Home Automation II represents the next evolution in smart home technology, providing users with greater flexibility, convenience, and security through advanced features and integrated systems. This smart home revolution focuses on the seamless interaction of devices and the automation of daily tasks, ultimately enhancing the overall living experience.

One of the key features of Home Automation II is interoperability among a wide range of devices. This enables homeowners to control lights, thermostats, security cameras, and other appliances from a single platform. Whether through smartphones, tablets, or voice-activated assistants, users can easily manage their home environment, monitor energy consumption, and receive real-time notifications. This level of integration not only simplifies operation but also creates a more cohesive smart home ecosystem.

Another significant aspect of Home Automation II is the use of artificial intelligence and machine learning. These technologies learn a homeowner’s habits and preferences, allowing the system to adapt automatically. For example, the thermostat can adjust temperatures based on the time of day and occupancy patterns, while lighting systems can simulate human presence when residents are away. This not only enhances comfort but also contributes to energy efficiency, leading to potential cost savings in utility bills.

Home Automation II offers enhanced security features as well. Smart locks, surveillance cameras, and motion detectors can all be integrated into the home’s network. This allows homeowners to monitor their property remotely, receive security alerts, and even grant access to visitors through mobile apps. Biometric security options, such as facial recognition, are also becoming more common, adding an extra layer of protection.

Furthermore, energy management technologies are a hallmark of Home Automation II. Smart plugs and sensors monitor energy use, providing insights to homeowners about how to reduce consumption. Advanced systems can even automate energy distribution, shifting usage to off-peak hours to alleviate strain on local grids and maximize efficiency.

Finally, voice control has become a prominent feature in Home Automation II, allowing users to operate devices hands-free. Integration with voice-activated platforms like Amazon Alexa, Google Assistant, and Apple Siri adds another layer of convenience, making it easy to control multiple aspects of the home with simple voice commands.

In conclusion, Home Automation II represents a significant step forward in creating intelligent spaces that are responsive to the needs of their users. Through the integration of cutting-edge technologies, enhanced security measures, energy management, and intuitive control options, the concept of a smart home is evolving into a more accessible and efficient reality.