Quick Arm

For extra convenience, the OmniPro II can be armed by simply pressing the DAY, NIGHT, or AWAY button twice, eliminating the need to enter the code.

To quick arm the system in the Away mode, from the top-level display, press AWAY AWAY .

The quick arm feature only works if the alarm system is in the Off mode, and if no alarms are sounding. This feature is disabled when the system is shipped. If desired, it can be enabled or disabled at any time - See Set Up Arming, Enable Quick Arm.

Bypassing Zones

8 = BYPASS

You can Bypass a zone that you do not want protected while the system is armed. Bypassing is also the only way that a tamper or panic zone can be disarmed. For example, if there is a liquor closet or gun case on a tamper zone, then you must bypass that zone to gain access to it.

Another reason to Bypass a zone is if the zone is having trouble. If a zone is causing a trouble indication, you can bypass that zone to "cut it out" of the system until repairs are made.

When a zone is bypassed, it is no longer checked for alarms. When you bypass a zone using the console (or over the phone) it will Stay bypassed until you Restore it. The console status display will show that the zone is bypassed only when the security system is disarmed. When the system is armed, it does not display bypassed zones.

To bypass a zone, from the main menu or from the top-level display, press 2 on the console keypad, then 8 for bypass. Enter the zone number followed by the ' # ' key, or use the arrow keys to select the zone. After the zone is entered, you will be prompted to enter your security code. The bottom line will now read "ZONE NAME BYPASSED" to remind you that the zone is bypassed.

If a fire zone is bypassed, the console will continue to beep until that zone is restored - See Restoring Zones.

Auto-Bypass

In order to prevent the alarm from sounding unexpectedly if a window or door is open when the system is armed, the OmniPro II will automatically bypass the zone if it is opened when the system is armed.

Note that there is an exit delay before the system is armed in any mode. The bypass will only take place if the zone is not ready (i.e. open) when the exit delay is over and the system is actually armed.

When a zone is Auto-Bypassed, it will be automatically restored once it is secure (i.e. closed), or the next time you arm or disarm the system. The auto-bypass is recorded in the event log as "ZONE NAME BYPASSED". To prevent any zone from being bypassed unintentionally, you should always look for "SYSTEM OK" on the display before arming and leaving the premises.

The Auto-Bypass feature can be disabled if you do not want the system to automatically bypass open zones. If the auto-bypass feature is disabled, the alarm will sound if a zone not ready (i.e. open) when the system is armed.

NOTE: The Auto-Bypass feature is disabled on UL Listed Installations.

Restoring Zones

9 = RESTORE

Restoring a zone puts it back on active duty in the system. When restored, the Bypassed indication will no longer be displayed on the status line and the zone will be checked for alarms.

To restore a zone, from the top-level display, press 2 on the console keypad, then 9 for restore.

Enter the zone number followed by the ' # ' key, or use the arrow keys to select the zone. Press ' 0 ' as the first key to restore all zones. The 0 = ALL choice is removed once a digit key or the down arrow is pressed. After the zone or all zones is entered, you will be prompted to enter your code. The console will beep and the display will return to the top-level display.

Page 8

Image 16
Contents Home AUTOMATION, INC Copyright 2001-2003 Home Automation, Inc All Rights Reserved Contents Control Telephone Control Page Fire Escape Planning Instructions to Called PartyPage Underwriters Laboratories UL Listing IntroductionModel Number Serial Number Overall Description Console OperationNormal Top-Level Display Display MenusError Beeps Main MenuTrouble Beeps To silence the beeper, press the * keyOmniPro II Maintenance CancelAreas Confirmation BeepDisarming the Security System and Silencing Alarms Security System OperationArming the Security System = OFFUsing Shortcut Keys = Night DLY Night Delay= Night = Vacation= Restore Quick ArmBypassing Zones Restoring ZonesWhat To Do When You Come Home What Happens When the Alarm is ActivatedBurglar Alarm Activated Burglar ALARM! Zone Name TrippedGas Alarm Activated Fire Alarm ActivatedEmergency Keys Alarm Reset Duress Code Entered or Duress Alarm ActivatedAlarm Cancel Codes Trouble IndicationsMaster Code Panic Switches Duress CodeArea Arming Manager CodeGoto Area Testing Your System Control Commands ALC Switch ModulesControl ModulesHouse Codes Unit NumbersScrolling Through Names Dimming and Brightening Controlling UnitsLighting Level Ramp Command Timed CommandsScene Command Compose Status of a Unit Internal FlagsControlling Outputs All On / OffLeviton Scene Control ScenesButtons Temperature Control HAI RC-Series ThermostatsIf hold mode is On, Hold is shown Programmable Energy Saver Modules PESMs Freeze Alarms Important NotesTemperature Alarms Outdoor TemperatureTemperature Control of Appliances HumidityStatus Through Event Log Show EventsMessages Record Memo MessagePlay Memo Message Clear Text MessagesShow Message Log MessageClear Message Say MessageSend Message Pro-Link Telephone Control Telephone InterfaceIn-House Phones Remote PhonesPhone Access Denied Remote Lockout Temperature Status Event Phone GOOD-BYE Cancel RepeatAlternate Method Main MenuTemperature ControlSecurity ButtonWhen an HAI Communicating Thermostat is entered Hold # Status CancelWhen a Programmable Energy Saver Pesm is entered Heat Setting Cool Setting Timed # Status * CancelPlaying and Recording a Message MessagePlaying and Recording a Custom Phrase Panic Button over the Phone # # # # # # Good-ByePlaying and Recording the Address Emergency Dial-Out Digital DialerVoice Dialer How the OmniPro II Voice Dialer WorksWhat You Hear If Your OmniPro II Calls You PC AccessEntering the Code Connecting to Network via PC Access Built-In Ethernet PortController IP Address, Port Number, and Encryption Key OmniPro II Ethernet ConnectionsDynamic DNS 192.168.0.101 Hub or HAI OmniPro IIRouter ControllerLocal / Wide Area Network Configuration and Advanced Control Programming ACP SetupSet Up Codes Set Up Time Duress Code= Add Programs Advanced Control Programming ACP= Show Programs Otherwise, a help screen is displayed Edit Programs = Delete All ProgramsEdit Programs When Edit When 1=TIMED 2=BUTTONTimes Programs Security Mode Event Buttons Control Unit Event / ALC Switch Press Event ButtonsButton and Event Programs Zone Event Buttons All On/Off Event Buttons Alarm Event ButtonsEvent Buttons Miscellaneous Event Buttons Message Event Buttons Pro-LinkProgram Control Commands Edit Program CommandProgram Security Commands Program Button Commands Program All On / All Off CommandsProgram Temperature Commands Program Message CommandsProgram Security Mode Conditions Edit Program ConditionProgram Control Conditions Program Zone ConditionsProgram Time Clock Conditions Program Other ConditionsSet Up Dial Dial Out Number Dial OUT 1 on Dial OUT 1 OFFDial Out Numbers Dial OrderSet Up Arming Set up Miscellaneous Format Number Description House Codes 2-16 X-10 All Off House Codes 2-16 X-10 All OnTime Clocks Time Clock 1 on Time Clock 1 OFFZone Name Latitude, Longitude, and Time ZoneDaylight Savings Controller IP Address Number DescriptionController Port Number Set Up Names Encryption KeySet Up Voice Set Up AddressUnderwriters Laboratories Requirements Fire Escape PlanningFederal Communication Commission Notice Home AUTOMATION, INC Powell Street Suite a NEW ORLEANS, LACanadian Industry Canada Notice If YOU have Trouble with Your PhonesAppendix a Dial OUT Planner OmniPro II Voice Dial-Out PlannerInstructions to Called Party Press 9. The system will say Good-bye and hang upCode Char Appendix B Text Description Character CodesSpace Appendix C Voice Description Codes Code DescriptionFault FallHello LowerSafety SwitchTemperature ServiceVolume VaultPhrase VCRPage

II specifications

Home Automation II represents the next evolution in smart home technology, providing users with greater flexibility, convenience, and security through advanced features and integrated systems. This smart home revolution focuses on the seamless interaction of devices and the automation of daily tasks, ultimately enhancing the overall living experience.

One of the key features of Home Automation II is interoperability among a wide range of devices. This enables homeowners to control lights, thermostats, security cameras, and other appliances from a single platform. Whether through smartphones, tablets, or voice-activated assistants, users can easily manage their home environment, monitor energy consumption, and receive real-time notifications. This level of integration not only simplifies operation but also creates a more cohesive smart home ecosystem.

Another significant aspect of Home Automation II is the use of artificial intelligence and machine learning. These technologies learn a homeowner’s habits and preferences, allowing the system to adapt automatically. For example, the thermostat can adjust temperatures based on the time of day and occupancy patterns, while lighting systems can simulate human presence when residents are away. This not only enhances comfort but also contributes to energy efficiency, leading to potential cost savings in utility bills.

Home Automation II offers enhanced security features as well. Smart locks, surveillance cameras, and motion detectors can all be integrated into the home’s network. This allows homeowners to monitor their property remotely, receive security alerts, and even grant access to visitors through mobile apps. Biometric security options, such as facial recognition, are also becoming more common, adding an extra layer of protection.

Furthermore, energy management technologies are a hallmark of Home Automation II. Smart plugs and sensors monitor energy use, providing insights to homeowners about how to reduce consumption. Advanced systems can even automate energy distribution, shifting usage to off-peak hours to alleviate strain on local grids and maximize efficiency.

Finally, voice control has become a prominent feature in Home Automation II, allowing users to operate devices hands-free. Integration with voice-activated platforms like Amazon Alexa, Google Assistant, and Apple Siri adds another layer of convenience, making it easy to control multiple aspects of the home with simple voice commands.

In conclusion, Home Automation II represents a significant step forward in creating intelligent spaces that are responsive to the needs of their users. Through the integration of cutting-edge technologies, enhanced security measures, energy management, and intuitive control options, the concept of a smart home is evolving into a more accessible and efficient reality.