Samsung AR12FSFTKWQNET Air flow Check if you have selected Auto/Dry Mode, Working Sensor, Room

Page 25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PROBLEM

SOLUTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air flow

• Check if you have selected Auto/Dry/

 

mode. In

 

 

 

 

adjustment is not

these modes, desired temperature is set to auto and you

 

 

 

 

working.

cannot adjust the temperature.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan speed

• Check if you have selected Auto/Dry/Turbo/

 

 

 

 

 

 

 

 

 

adjustment is not

mode. In these mode, fan speed is set to Auto and you

 

 

 

 

working.

cannot adjust the fan speed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remote

• Check if your batteries are depleted.

 

 

 

 

 

 

 

 

 

controller is not

• Make sure nothing is blocking your remote controller

 

 

 

 

working.

sensor.

 

 

 

 

 

 

Check that there are strong lighting apparatus near the air conditioner. Strong light which comes from fluorescent bulbs or neon signs may interrupt the electric waves.

Timer function

• Check if you press the Set button on the remote controller

does not set.

after you have set the time.

 

 

 

The indicator

• Press the Power

button or disconnect the power plug/

is blinking

switch off the auxiliary power switch.

continuously.

If the indicator is still blinking, contact the service center.

 

 

Odors permeate

• Check if the appliance is running in a smoky area. Ventilate

in the room

the room or operate the air conditioner in Fan mode for

during operation.

1~2 hours. (We do not use smelly components in the air

 

conditioner.)

 

 

 

Error is indicated.

• When an indoor unit indicator blinks, contact the nearest

 

service center.

 

 

 

Noise is

• Depending on the status of the air conditioner usage, noise

generated.

can be heard when refrigerant flow movement changes. It is

 

normal.

 

 

 

Smoke is

• If may not be a fire but it can be a steam generated by the

generated from

defrost operation from outdoor heat exchanger during Heat

the outdoor unit.

mode in winter.

 

 

 

Water is dropping

• Water may be generated because of the temperature

from the outdoor

difference. It is normal.

unit piping

 

 

connection.

 

 

 

 

 

 

 

25

ENGLISH

Boracay ET_AR09FSFT@_IBIM_DB68-03377A_EN-7.indd 25

2014/12/11 17:23:04

Image 25
Contents Boracay ETAR09FSFT@IBIMDB68-03377AEN-7.indd 2014/12/11 Contents Important safety symbols and precautions Safety precautionsPersonal injury or death Personal injury or property damageFor Installation Caution For Using Do not touch the circuit breaker with wet hands Do not place objects or devices under the indoor unit Do not drink the water from the air conditioner Do not operate the appliance with wet handsDo not touch the pipes connected with the product Do not clean the inside of the air conditioner by yourself For CleaningOperation ranges Checking before useChecking the name of the parts Power buttonMain parts DisplayRemote controller buttons Checking the remote controllerBattery changing time Remote controller displayStoring the remote controller Inserting the batteriesBasic function Press Button to adjust the temperatureUsing the Turbo function Adjusting the air flow directionPress the Air swing button on the remote controller Vertical air flowPress the button on the remote controller When the air conditioner is on and in cool/heat modeMode Press the Time Up or Time Down button to set the timePress the On Timer/Off Timer button Setting the On/Off timerCancel Press the Cancel button Additional options available in On timer modeFrom the moment you have set the timer Using the Smart Saver functionIf the air conditioner is on If the air conditioner is off Turn off automaticallyUsing the Auto Clean function Using the Quiet functionWhen the air conditioner is turned on You can reduce the noise generated from an indoor unitMake sure the power is turned off and unplugged from Cleaning the air conditionerCleaning the indoor unit Cleaning the outdoor unit heat exchangerRemoving the Air filter Cleaning the air filterOpen the panel and put the Air filter out Dry the Air filter in a ventilated areaMaintaining the air conditioner Clean the condensate drain panTroubleshooting Timer function Working Cannot adjust the temperature Fan speedIndicator Air flow Check if you have selected Auto/Dry Mode.Included Models Remark General informationInstalling the unit Choosing the installation locationPower supply line, fuse or circuit breaker  a place where the air filter can be replaced easilyOutdoor Unit Where sulfide gas existsWhen the air outlet is towards the wall When installing more than 1 outdoor unit Figure Description Top view Side viewAccessories in the indoor unit case AccessoriesAccessories in the outdoor unit case Optional accessories Fixing the installation plateTools required for installation General Tools Tools for test operationsCable specification Connecting the assembly cableConnecting the cable Each wire is labeled with the corresponding terminal number Extend the assembly cable if necessaryCut off the remaining foam insulation Smooth the cut edgesCutting or extending the pipe Purging the indoor unitUnscrew the caps at the end of each pipe Put a flare nut slightly into the pipe and modify the flareCorrect Inclined Pipe 50 Pa. The joint must be accessible and serviceableCracked Outer DiameterChanging direction of the drain hose Drain hose installationConnect a drain hose to the drain plug Purging the connected pipesEnsure that condensation draining is adequate If you use a pipe longer than 5m Adding RefrigerantIf you use a pipe shorter than 5m Model the factory refrigerant charge of the product Please fill in with indelible ink2088 To check for gas leaks on the outdoor unit Performing the gas leak testsTo check for gas leaks on the indoor unit Leak test with nitrogen before opening valvesThen place the indoor unit on the installation plate Outdoor unit installed on the wall by rackFixing the indoor unit in place Fixing the outdoor unit in placeFinal Check and Trial Operation Apply heat to the contraction tube to contract it How to connect your extended power cablesAfter tube contraction work is completed, wrap it with Insulation tape to finishEnglish Questions or COMMENTS? Air Conditioner
Related manuals
Manual 45 pages 3.43 Kb Manual 47 pages 32.01 Kb Manual 45 pages 23.12 Kb Manual 1 pages 28.11 Kb Manual 45 pages 45.25 Kb Manual 1 pages 30.65 Kb Manual 45 pages 732 b Manual 43 pages 53.57 Kb Manual 45 pages 260 b Manual 1 pages 28.15 Kb Manual 1 pages 28.19 Kb Manual 1 pages 28.11 Kb Manual 1 pages 28.18 Kb

AR12FSFTKWQNZE, AR09FSFTKWQNET, AR12FSFTKWQNET, AR12HSFTKWQNET, AR12FSFTJWQNET specifications

The Samsung AR09HSFTKWQNET and AR09HSFTKWQXET are two standout models in Samsung’s line of air conditioning units, designed to deliver powerful cooling and energy efficiency in residential and commercial spaces. Both models incorporate advanced technologies and user-friendly features that enhance user comfort while minimizing energy consumption.

One of the main features of these units is their use of Digital Inverter Technology. This innovative system maintains the desired temperature without frequent on-off cycling, reducing energy consumption by up to 60% when compared to traditional air conditioners. The Digital Inverter allows the compressor to adjust its speed based on the cooling demand, ensuring a consistent and comfortable environment without dramatic fluctuations in temperature.

In addition to energy efficiency, the Samsung AR09HSFTKWQNET and AR09HSFTKWQXET are equipped with a powerful air filtration system. The Triple Protection Filter not only captures dust and allergens but is also easy to clean and maintain. This means that indoor air quality remains high, making these units particularly suitable for allergy sufferers and those looking for a cleaner living environment.

The design of both models blends seamlessly with any decor, featuring a sleek and modern exterior. The additional LED display allows users to monitor settings easily, further enhancing the user experience. Each model comes with a remote control, enabling the user to adjust temperature and settings from anywhere in the room.

Noise levels are another key characteristic of the Samsung AR09HSFTKWQNET and AR09HSFTKWQXET. These air conditioners operate quietly, making them ideal for bedrooms and workspaces where noise disruption is not welcome. This is further enhanced by the indoor units’ acoustic insulation, which minimizes sound transmission.

Another remarkable aspect is their quick cooling function. With the option to reach the desired temperature rapidly, users can enjoy immediate relief from heat, making these air conditioners perfect for hot climates.

To underscore their commitment to sustainability, Samsung designs these models with eco-friendly refrigerants, further contributing to lower environmental impact while still maintaining high performance.

In summary, the Samsung AR09HSFTKWQNET and AR09HSFTKWQXET embody cutting-edge technology combined with user-centric features. Their energy-efficient operations, advanced air filtration, stylish design, and quiet functioning make them an excellent choice for anyone seeking a dependable and effective cooling solution.