Installing and connecting the drain hose of the outdoor unit

While heating, ice may accumulate. During the process of defrosting, check if condensation draining is adequate. For adequate

draining, do the following:

1. Insert the drain plug into the drain hole on the underside of the outdoor unit.

• To avoid drain plug from contacting the ground, secure gap between the

Drain hole

 

ground and the bottom surface of the outdoor unit.

Drain plug

 

 

 

 

Bottom surface of outdoor unit

2. Connect a drain hose to the drain plug.

Drain hole

 

Drain plug

Drain hose

Snow-proof hood

3. Ensure that condensation draining is adequate.

• In areas with heavy snow fall, piled snow could block the air intake.

To avoid this incident, install a frame that is higher than estimated snow

Estimated

fall. In addition, install a snow-proof hood to avoid snow from piling on the

snow fall Frame

outdoor unit.

 

Ground

Purging the connected pipes

The outdoor unit is loaded with sufficient R-410A refrigerant. Do not vent R-410A into atmosphere: it is a fluorinated greenhouse gas, covered by Kyoto Protocol, with a Global Warming Potential (GWP) = 2088.

You should purge the air in the indoor unit and in the pipe. If air remains in the refrigerant pipes, it affects the compressor. It may cause reduction of cooling capacity and malfunction. Refrigerant for air purging is not charged in the outdoor unit. Use Vacuum Pump as seen in the picture.

• When installing, make sure there is no leakage. When recovering the refrigerant, ground the compressor first

before removing the connection pipe. If the refrigerant pipe is not properly connected and the compressor works with the service valve open, the pipe inhales the air and it makes the pressure inside of the refrigerant cycle

abnormally high. It may cause explosion and injury.

1.Connect each assembly pipe to the appropriate valve on the outdoor unit and tighten the flare nut.

2.Tighten the flare nut first with your hands, and then with a torque wrench, applying the following torque:

• Excessive torque can be cause of gas leakage.

• Make the electrical connection and leave the system into“stand by mode”. Do not turn on the system!

This is necessary for better vacuum operation (full OPEN position of Electronic Expansion Valve - EEV -).

Outdoor unit

Indoor unit

 

Gas pipe side

 

Liquid pipe side

Outer Diameter

Torque (kgf•cm)

ø6.35 mm

140~170

ø9.52 mm

250~280

ø12.70 mm

380~420

ø15.88 mm

440~480

ø19.05 mm

990~1210

ø22.23 mm

990~1210

38

Boracay ET_AR09FSFT@_IBIM_DB68-03377A_EN-7.indd 38

2014/12/11 17:23:10

Image 38
Contents Boracay ETAR09FSFT@IBIMDB68-03377AEN-7.indd 2014/12/11 Contents Personal injury or death Safety precautionsImportant safety symbols and precautions Personal injury or property damageFor Installation Caution For Using Do not touch the circuit breaker with wet hands Do not place objects or devices under the indoor unit Do not touch the pipes connected with the product Do not operate the appliance with wet handsDo not drink the water from the air conditioner For Cleaning Do not clean the inside of the air conditioner by yourselfChecking before use Operation rangesMain parts Power buttonChecking the name of the parts DisplayChecking the remote controller Remote controller buttonsStoring the remote controller Remote controller displayBattery changing time Inserting the batteriesBasic function Button to adjust the temperature PressPress the Air swing button on the remote controller Adjusting the air flow directionUsing the Turbo function Vertical air flowMode When the air conditioner is on and in cool/heat modePress the button on the remote controller Press the Time Up or Time Down button to set the timeCancel Press the Cancel button Setting the On/Off timerPress the On Timer/Off Timer button Additional options available in On timer modeIf the air conditioner is on If the air conditioner is off Using the Smart Saver functionFrom the moment you have set the timer Turn off automaticallyWhen the air conditioner is turned on Using the Quiet functionUsing the Auto Clean function You can reduce the noise generated from an indoor unitCleaning the indoor unit Cleaning the air conditionerMake sure the power is turned off and unplugged from Cleaning the outdoor unit heat exchangerOpen the panel and put the Air filter out Cleaning the air filterRemoving the Air filter Dry the Air filter in a ventilated areaClean the condensate drain pan Maintaining the air conditionerTroubleshooting Indicator Working Cannot adjust the temperature Fan speedTimer function Air flow Check if you have selected Auto/Dry Mode.General information Included Models RemarkPower supply line, fuse or circuit breaker Choosing the installation locationInstalling the unit  a place where the air filter can be replaced easilyWhere sulfide gas exists Outdoor Unit Figure Description When installing more than 1 outdoor unitWhen the air outlet is towards the wall Top view Side viewAccessories in the outdoor unit case AccessoriesAccessories in the indoor unit case Tools required for installation General Tools Fixing the installation plateOptional accessories Tools for test operationsConnecting the cable Connecting the assembly cableCable specification Extend the assembly cable if necessary Each wire is labeled with the corresponding terminal numberSmooth the cut edges Cut off the remaining foam insulationUnscrew the caps at the end of each pipe Purging the indoor unitCutting or extending the pipe Put a flare nut slightly into the pipe and modify the flareCracked Pipe 50 Pa. The joint must be accessible and serviceableCorrect Inclined Outer DiameterDrain hose installation Changing direction of the drain hoseEnsure that condensation draining is adequate Purging the connected pipesConnect a drain hose to the drain plug If you use a pipe shorter than 5m Adding RefrigerantIf you use a pipe longer than 5m Model2088 Please fill in with indelible ink the factory refrigerant charge of the product To check for gas leaks on the indoor unit Performing the gas leak testsTo check for gas leaks on the outdoor unit Leak test with nitrogen before opening valvesFixing the indoor unit in place Outdoor unit installed on the wall by rackThen place the indoor unit on the installation plate Fixing the outdoor unit in placeFinal Check and Trial Operation After tube contraction work is completed, wrap it with How to connect your extended power cablesApply heat to the contraction tube to contract it Insulation tape to finishEnglish Questions or COMMENTS? Air Conditioner
Related manuals
Manual 45 pages 3.43 Kb Manual 47 pages 32.01 Kb Manual 45 pages 23.12 Kb Manual 1 pages 28.11 Kb Manual 45 pages 45.25 Kb Manual 1 pages 30.65 Kb Manual 45 pages 732 b Manual 43 pages 53.57 Kb Manual 45 pages 260 b Manual 1 pages 28.15 Kb Manual 1 pages 28.19 Kb Manual 1 pages 28.11 Kb Manual 1 pages 28.18 Kb

AR12FSFTKWQNZE, AR09FSFTKWQNET, AR12FSFTKWQNET, AR12HSFTKWQNET, AR12FSFTJWQNET specifications

The Samsung AR09HSFTKWQNET and AR09HSFTKWQXET are two standout models in Samsung’s line of air conditioning units, designed to deliver powerful cooling and energy efficiency in residential and commercial spaces. Both models incorporate advanced technologies and user-friendly features that enhance user comfort while minimizing energy consumption.

One of the main features of these units is their use of Digital Inverter Technology. This innovative system maintains the desired temperature without frequent on-off cycling, reducing energy consumption by up to 60% when compared to traditional air conditioners. The Digital Inverter allows the compressor to adjust its speed based on the cooling demand, ensuring a consistent and comfortable environment without dramatic fluctuations in temperature.

In addition to energy efficiency, the Samsung AR09HSFTKWQNET and AR09HSFTKWQXET are equipped with a powerful air filtration system. The Triple Protection Filter not only captures dust and allergens but is also easy to clean and maintain. This means that indoor air quality remains high, making these units particularly suitable for allergy sufferers and those looking for a cleaner living environment.

The design of both models blends seamlessly with any decor, featuring a sleek and modern exterior. The additional LED display allows users to monitor settings easily, further enhancing the user experience. Each model comes with a remote control, enabling the user to adjust temperature and settings from anywhere in the room.

Noise levels are another key characteristic of the Samsung AR09HSFTKWQNET and AR09HSFTKWQXET. These air conditioners operate quietly, making them ideal for bedrooms and workspaces where noise disruption is not welcome. This is further enhanced by the indoor units’ acoustic insulation, which minimizes sound transmission.

Another remarkable aspect is their quick cooling function. With the option to reach the desired temperature rapidly, users can enjoy immediate relief from heat, making these air conditioners perfect for hot climates.

To underscore their commitment to sustainability, Samsung designs these models with eco-friendly refrigerants, further contributing to lower environmental impact while still maintaining high performance.

In summary, the Samsung AR09HSFTKWQNET and AR09HSFTKWQXET embody cutting-edge technology combined with user-centric features. Their energy-efficient operations, advanced air filtration, stylish design, and quiet functioning make them an excellent choice for anyone seeking a dependable and effective cooling solution.