• For the terminal block wiring, use a wire with a ring terminal socket only.

Regular wires without a ring terminal socket may become a fire hazard due to overheating of the electrical contact during a wiring work.

When you install the unit, make first refrigerant connections and then electrical connections. Connect the air conditioner to grounding system before performing the electrical connection. If unit is uninstalled, first disconnect electrical cables, then refrigerant connections.

If the outdoor unit is more than 5 meters away from the indoor unit, you must extend the cable. The maximum length of the cable is 15(09/12)/20(18/24) meters.

1. Extend the assembly cable if necessary.

• Do not connect two or more different cables to extend the length.

It may cause fire.

2 . Open the front grille.

3 . Remove the screw securing the connector cover.

4 . Pass the assembly cable through the rear of the indoor unit and connect the assembly cable to terminals. (Refer to the picture below)

• Each wire is labeled with the corresponding terminal number.

5 . Pass the other end of the cable through the 65mm hole in the wall.

6 . Close the connector cover by tightening the screw carefully.

7 . Close the front grille.

8 . Remove the terminal board cover on the side of the outdoor unit. 9. Connect the cables to the terminals as seen in the picture.

• Each wire is labeled with the corresponding terminal number.

ENGLISH

Indoor unit

Indoor unit

Outdoor unit

F1

F2

Outdoor unit

1(L)

2(N)

F1

F2

1(L)

2(N)

F1

F2

L

N

• End of the wire must be circular.

• After connecting the cables, make sure terminal numbers on the indoor/outdoor unit matches.

Screws on terminal block must not be unscrewed with the torque less than 12kgf•cm.

10.Connect the grounding conductor to the grounding terminals.

11.Close the terminal board cover by tightening the screw carefully.

• In Russia and Europe, consult with the supply authority to determine the supply system impedance before

installation.

• Connect the wires firmly so that wires can not be pulled out easily. (If they are loose, it could cause burn-out of the wires.)

• Connect the wires according to color codes, referring to the wiring diagram.

• The power cable and the interconnection cable should be selected according to the specification in page 32.

33

Boracay ET_AR09FSFT@_IBIM_DB68-03377A_EN-7.indd 33

2014/12/11 17:23:08

Image 33
Contents Boracay ETAR09FSFT@IBIMDB68-03377AEN-7.indd 2014/12/11 Contents Important safety symbols and precautions Safety precautionsPersonal injury or death Personal injury or property damageFor Installation Caution For Using Do not touch the circuit breaker with wet hands Do not place objects or devices under the indoor unit Do not operate the appliance with wet hands Do not drink the water from the air conditionerDo not touch the pipes connected with the product Do not clean the inside of the air conditioner by yourself For CleaningOperation ranges Checking before useChecking the name of the parts Power buttonMain parts DisplayRemote controller buttons Checking the remote controllerBattery changing time Remote controller displayStoring the remote controller Inserting the batteriesBasic function Press Button to adjust the temperatureUsing the Turbo function Adjusting the air flow directionPress the Air swing button on the remote controller Vertical air flowPress the button on the remote controller When the air conditioner is on and in cool/heat modeMode Press the Time Up or Time Down button to set the timePress the On Timer/Off Timer button Setting the On/Off timerCancel Press the Cancel button Additional options available in On timer modeFrom the moment you have set the timer Using the Smart Saver functionIf the air conditioner is on If the air conditioner is off Turn off automaticallyUsing the Auto Clean function Using the Quiet functionWhen the air conditioner is turned on You can reduce the noise generated from an indoor unitMake sure the power is turned off and unplugged from Cleaning the air conditionerCleaning the indoor unit Cleaning the outdoor unit heat exchangerRemoving the Air filter Cleaning the air filterOpen the panel and put the Air filter out Dry the Air filter in a ventilated areaMaintaining the air conditioner Clean the condensate drain panTroubleshooting Timer function Working Cannot adjust the temperature Fan speedIndicator Air flow Check if you have selected Auto/Dry Mode.Included Models Remark General informationInstalling the unit Choosing the installation locationPower supply line, fuse or circuit breaker  a place where the air filter can be replaced easilyOutdoor Unit Where sulfide gas existsWhen the air outlet is towards the wall When installing more than 1 outdoor unit Figure Description Top view Side viewAccessories Accessories in the indoor unit caseAccessories in the outdoor unit case Optional accessories Fixing the installation plateTools required for installation General Tools Tools for test operationsConnecting the assembly cable Cable specificationConnecting the cable Each wire is labeled with the corresponding terminal number Extend the assembly cable if necessaryCut off the remaining foam insulation Smooth the cut edgesCutting or extending the pipe Purging the indoor unitUnscrew the caps at the end of each pipe Put a flare nut slightly into the pipe and modify the flareCorrect Inclined Pipe 50 Pa. The joint must be accessible and serviceableCracked Outer DiameterChanging direction of the drain hose Drain hose installationPurging the connected pipes Connect a drain hose to the drain plugEnsure that condensation draining is adequate If you use a pipe longer than 5m Adding RefrigerantIf you use a pipe shorter than 5m ModelPlease fill in with indelible ink  the factory refrigerant charge of the product2088 To check for gas leaks on the outdoor unit Performing the gas leak testsTo check for gas leaks on the indoor unit Leak test with nitrogen before opening valvesThen place the indoor unit on the installation plate Outdoor unit installed on the wall by rackFixing the indoor unit in place Fixing the outdoor unit in placeFinal Check and Trial Operation Apply heat to the contraction tube to contract it How to connect your extended power cablesAfter tube contraction work is completed, wrap it with Insulation tape to finishEnglish Questions or COMMENTS? Air Conditioner
Related manuals
Manual 45 pages 3.43 Kb Manual 47 pages 32.01 Kb Manual 45 pages 23.12 Kb Manual 1 pages 28.11 Kb Manual 45 pages 45.25 Kb Manual 1 pages 30.65 Kb Manual 45 pages 732 b Manual 43 pages 53.57 Kb Manual 45 pages 260 b Manual 1 pages 28.15 Kb Manual 1 pages 28.19 Kb Manual 1 pages 28.11 Kb Manual 1 pages 28.18 Kb

AR12FSFTKWQNZE, AR09FSFTKWQNET, AR12FSFTKWQNET, AR12HSFTKWQNET, AR12FSFTJWQNET specifications

The Samsung AR09HSFTKWQNET and AR09HSFTKWQXET are two standout models in Samsung’s line of air conditioning units, designed to deliver powerful cooling and energy efficiency in residential and commercial spaces. Both models incorporate advanced technologies and user-friendly features that enhance user comfort while minimizing energy consumption.

One of the main features of these units is their use of Digital Inverter Technology. This innovative system maintains the desired temperature without frequent on-off cycling, reducing energy consumption by up to 60% when compared to traditional air conditioners. The Digital Inverter allows the compressor to adjust its speed based on the cooling demand, ensuring a consistent and comfortable environment without dramatic fluctuations in temperature.

In addition to energy efficiency, the Samsung AR09HSFTKWQNET and AR09HSFTKWQXET are equipped with a powerful air filtration system. The Triple Protection Filter not only captures dust and allergens but is also easy to clean and maintain. This means that indoor air quality remains high, making these units particularly suitable for allergy sufferers and those looking for a cleaner living environment.

The design of both models blends seamlessly with any decor, featuring a sleek and modern exterior. The additional LED display allows users to monitor settings easily, further enhancing the user experience. Each model comes with a remote control, enabling the user to adjust temperature and settings from anywhere in the room.

Noise levels are another key characteristic of the Samsung AR09HSFTKWQNET and AR09HSFTKWQXET. These air conditioners operate quietly, making them ideal for bedrooms and workspaces where noise disruption is not welcome. This is further enhanced by the indoor units’ acoustic insulation, which minimizes sound transmission.

Another remarkable aspect is their quick cooling function. With the option to reach the desired temperature rapidly, users can enjoy immediate relief from heat, making these air conditioners perfect for hot climates.

To underscore their commitment to sustainability, Samsung designs these models with eco-friendly refrigerants, further contributing to lower environmental impact while still maintaining high performance.

In summary, the Samsung AR09HSFTKWQNET and AR09HSFTKWQXET embody cutting-edge technology combined with user-centric features. Their energy-efficient operations, advanced air filtration, stylish design, and quiet functioning make them an excellent choice for anyone seeking a dependable and effective cooling solution.