Choosing the installation location

(Unit : mm)

When the walls are blocking front and the rear side of the outdoor units When the upper part of the outdoor unit and the air outlet is opposite the wall

 

 

 

 

300 or more

more

300 or more

 

 

 

 

 

 

600 or more

 

 

600 or more

1500 or more

500 or

 

When front and rear side of the outdoor unit is towards the wall

 

 

 

 

 

 

moreor500

300 or more

 

 

 

 

 

 

1500 or

600 or

3000 or

3000 or

200 or

 

more

more

more

more

 

more

 

• If installation is done in inappropriate space, unit may generate sound and cause bad effect on the product.

• Installation must be done in level and in a place where vibration will not cause any effect.

Accessories

The following accessories are supplied with the air conditioner:

• The number of each accessory is indicated in parentheses.

Accessories in the indoor unit case

Installation Plate (1)

Remote controller (1)

Batteries for Remote controller (2)

User’s & Installation Manual (1)

Accessories in the outdoor unit case

2-wire

Assembly Cable (1)

3-wire

Assembly Cable (1)

Drain Plug (1)

Rubber Leg (4)

• The flare nuts are attached to the end of each pipe of an evaporator or a service port.

Use the nuts when connecting the pipes.

The (2)3-wire assembly cable is optional. If it is not supplied, use the standard cable.

The drain plug and rubber leg are only included when the air conditioner is supplied without the assembly pipe as seen in the picture.

26

Vivaldi Cystal EUR_AQV09E@@ IB&IM_32449A_E.indd 26

2011-3-7 15:45:24

Image 26
Contents Vivaldi Cystal EURAQV09E@@ IB&IM32449AE.indd 2011-3-7 Contents Follow directions Safety precautionsImportant safety symbols and precautions Wall socketFor Using For Cleaning Checking before use Operation rangesMain parts PowerChecking the name of the parts DisplayChecking the remote controller Remote controller buttonsStoring the remote controller Remote controller displayBattery changing time Inserting the batteriesBasic function Button to adjust the temperature PressPress the Air swing button on the remote controller Adjusting the air flow directionUsing the Turbo function Vertical air flowPress the Set/Cancel button to active it on When the air conditioner is on and in cool/heat modePress the button on the remote controller ModePress the On Timer/Off Timer button to set the time Setting the On/Off timerPress the On Timer/Off Timer button Using the SPi function Using the Smart Saver functionWhen the air conditioner is turned on Using the Quiet functionUsing the Auto Clean function You can reduce the noise generated from an indoor unitCleaning the outdoor unit heat exchanger Cleaning the air conditionerCleaning the indoor unit Opening the panelOpen the panel and put the Air filter out Cleaning the air filterRemoving the Air filter Dry the Air filter in a ventilated areaMaintaining the air conditioner Periodical checksTroubleshooting Connection Outdoor unit Heat exchanger during Heat mode in winterFlow movement changes. It is normal AQV09E, AQV12E, AQV18E, AQV24E General informationIncluded Models Remark Power supply line, fuse or circuit breaker Choosing the installation locationInstalling the unit  a place where the air filter can be replaced easilyWhere sulfide gas exists Outdoor Unit Figure Description When installing more than 1 outdoor unitWhen the air outlet is towards the wall Top view Side viewAccessories in the outdoor unit case AccessoriesAccessories in the indoor unit case Tools required for installation General Tools Fixing the installation plateOptional accessories Tools for test operationsConnecting the cable Connecting the assembly cableCable specification Each wire is labeled with the corresponding terminal number Smooth the cut edges Cut off the remaining foam insulationUnscrew the caps at the end of each pipe Purging the indoor unitCutting or extending the pipe Put a flare nut slightly into the pipe and modify the flareCracked Pipe 50 Pa. The joint must be accessible and serviceableCorrect Inclined Outer DiameterDrain hose installation Ensure that condensation draining is adequate Purging the connected pipesConnect a drain hose to the drain plug Adding Refrigerant 1975 Please fill in with indelible ink the factory refrigerant charge of the product To check for gas leaks on the indoor unit Performing the gas leak testsTo check for gas leaks on the outdoor unit Leak test with nitrogen before opening valvesFixing the indoor unit in place Outdoor unit installed on the wall by rackThen place the indoor unit on the installation plate Fixing the outdoor unit in placeFinal Check and Trial Operation After tube contraction work is completed, wrap it with How to connect your extended power cablesApply heat to the contraction tube to contract it Insulation tape to finishEnglish 70 70 19 42 277267864, € 0.07/min +381Air Conditioner
Related manuals
Manual 23 pages 41.95 Kb Manual 23 pages 55.9 Kb Manual 25 pages 14.93 Kb Manual 39 pages 27.14 Kb