Entry/Exit Delays (Continued)

Exit Alarms

Exit Error Conditions

Whenever you arm the system, the exit delay begins. If an entry/exit door or interior zone is faulted before exit delay expires and remains faulted (e.g., exit door left open), the system sounds an alarm and starts the entry delay timer. If you disarm the system before the entry delay ends, the alarm sound stops and the message "ALARM CANCELED " or "CA" is displayed on the keypad, along with a zone number indicating the faulted zone. No message is sent to the Central Monitoring Station.

To clear the exit error condition, the open zone must be made intact; to clear the display, enter your code plus OFF.

If you do not disarm the system before the entry delay ends and the faulted zone remains open, the alarm sound continues and an "exit alarm" message is sent to the Central Monitoring Station (after the installer-programmed dial delay expires). The message "EXIT ALARM" or "EA" is displayed on the keypad, along with a zone number indicating the faulted zone. To stop the alarm, the system must be disarmed (your code plus OFF); to clear the display, enter your code plus OFF a second time.

An “exit alarm” also results if an entry/exit door or interior zone is faulted within two minutes after the end of the exit delay.

Your system may have been programmed for this feature to minimize false alarms sent to the Central Monitoring Station. Ask your installer if "Exit Alarm" is active in your system. If so, check this box.

FA168CPSSIA/FA148CPSIA: The Exit Error condition works the same as described above, except that in addition to the “EXIT ALARM” message, a “zone alarm” message is also sent to the Central Monitoring Station. In addition, if an entry/exit door or interior zone is faulted within two minutes after the end of the exit delay, a “Recent Closing” condition occurs instead of the “exit alarm.” Refer to the next paragraph for details.

“Recent Closing” Condition (FA168CPSSIA/FA148CPSIA)

A Recent Closing condition is similar to the Exit Error condition described above, but occurs if an entry/exit door or interior zone is faulted within two minutes after the initial exit delay expires. If you disarm the system within the two minutes, the alarm sound stops and the message "ALARM CANCELED " or "CA" is displayed on the keypad, along with a zone number indicating the faulted zone. No message is sent to the Central Monitoring Station.

If you do not disarm the system within two minutes and the faulted zone remains open, the alarm sound continues and a “recent closing” and a “zone alarm” message are sent to the Central Monitoring Station (after the installer-programmed dial delay expires). The alarm message along with a faulted zone number is displayed on the keypad. To stop the alarm, the system must be disarmed (your code plus OFF); to clear the display, enter your code plus OFF a second time.

– 13 –

Image 13
Contents FA168CPS / FA168CPSSIA FA148CP / FA148CPSIA About This Manual Table of Contents Event Logging Procedures Using Device Commands Paging FeaturePanic Keys Macro Key Programming & Usage Security Codes & Authority LevelsIntroduction System OverviewSystem Basics Memory of Alarm AlarmsZones and Partitions Arming, Step-Arming and Disarming Burglary ProtectionPhone Access Using the Voice Message Center if Voice Keypad is installedMessage Center Functions General Information About The KeypadsFixed-Word Display Keypad Display Window Functions of the KeypadsStay Exit Delay Entry/Exit DelaysEntry Delay Exit Error Conditions Exit AlarmsTo turn the Voice Status feature on/off # Using the ∗ KeyChecking For Open Zones Arming the System Modes of Arming Press these keys… Keypad Confirms By… Arming CommandsQuick Arming Function Key ArmingSingle Button Arming Step Arming FeatureKey First Press Second Press Third Press Using the Keyswitch Using the KeyswitchTo arm in the Away mode To arm in the Stay modeUsing the OFF key Disarming and Silencing AlarmsBypassing Protection Zones Using the Bypass KeyQuick Bypass To turn Chime Mode on Chime ModeTo turn Chime Mode off To turn Voice Chime Mode on or offDate and Time Setting the Date and TimeViewing the Current Date and Time This Function Sends this signal With This Sounding… Using Panic KeysPanic Keys To activate a Panic FunctionAbout Macro Keys Macro Key Programming & UsageExample of Macro Programming Using a Programmed Macro KeyAbout Device Commands Using Device CommandsTo Activate Devices To Deactivate DevicesAbout Automatic Paging Paging FeatureLatch Key Paging Manual PagingAbout Security Codes Security Codes & Authority LevelsAuthority Level Definitions How to Assign Security Codes and Attributes About Accessing Partitions Accessing Other Partitions FA168CPSUsing the GoTo Command Accessing Other PartitionsMulti-Partition Arming Common Zone Operation About Scheduling SchedulingCreating Schedules Group Number Partition Start Smtwtfs About Event Logging Event Logging ProceduresViewing the Event Log Understanding the Type of Event DisplayedAbout Testing the System Testing the System To Be Conducted WeeklyTrouble Conditions Check and Battery DisplaysFault AlarmRcvr Jam Or CheckLong Rng Trbl Busy-StandbyMaintaining Your System Silencing Low Battery Warning Tones at KeypadThis Section Applies only to Residential Systems Fire Alarm System If InstalledOr Key Pairs Emergency Individual KeysKitchen Dining Emergency Evacuation Quick Guide to Basic System Functions Function Procedure CommentsFixed-Word Display Keypads Summary of Audible/Visual NotificationsSummary of Audible/Visual Notifications Federal Communications Commission FCC Part 15 Statement Regulatory Statements and WarningsRegulatory Statements Function Keys Comments Charts of Your System’s FeaturesCharts of Your System’s Features User User’s Parts Security Auth Access RF Zone Pager No. † Paging Setup List of Output Devices Page Page Page Page OWNER’S Insurance Premium Credit Request Cont Limitations of this System ÊK5309-5V5MŠ

FA168CPS specifications

The Garmin FA168CPS is an advanced navigation device designed primarily for marine use, offering a multitude of features tailored to enhance the user experience on the water. One of its standout characteristics is its high-resolution, sunlight-readable display, which ensures optimal visibility even in bright conditions. The screen is designed to provide clear, detailed maps and graphical data, making navigation easier and more efficient for boaters and sailors alike.

Equipped with GPS and GLONASS technology, the FA168CPS delivers rapid and precise positioning capabilities. This dual-satellite system enhances reliability and coverage, particularly in challenging maritime environments. The device also incorporates a built-in Fishfinder, allowing anglers to locate fish with ease. With advanced sonar capabilities, including CHIRP technology, users can distinguish between different types of fish and underwater structures, significantly increasing their chances of successful fishing trips.

One of the key features of the Garmin FA168CPS is its compatibility with various marine networks. It supports NMEA 2000 for seamless connectivity with other marine devices, allowing users to integrate their navigation system with autopilots, engines, and sensors for streamlined operation. This interoperability enhances situational awareness and greatly improves safety on the water.

Additionally, the FA168CPS comes with preloaded maps and charts, offering comprehensive coverage for coastal and inland waters. The device can also be upgraded with additional Garmin BlueChart g3 maps, providing users with the most up-to-date navigational data, including buoy locations, tidal information, and depth contours.

Among its user-friendly characteristics, the Garmin FA168CPS features intuitive menus and customizable screen layouts, allowing users to personalize their navigation experience. Its robust construction ensures durability in marine environments, making it resistant to water and other harsh conditions. The device is also designed for easy installation, ensuring that boaters can set it up quickly and get right to their adventures.

In summary, the Garmin FA168CPS combines cutting-edge technology with practical features to provide a comprehensive marine navigation solution. From its excellent display and advanced sonar capabilities to its compatibility with marine networks and customizable user interface, this device is an essential tool for anyone looking to navigate the waters with confidence and precision.