WIRING: 9-PIN Connector Cont.
Green/Red:
This is a programmable output that can operate two different ways: 1. (DEFAULT) A Remote Auxiliary Output that provides a ½ second
NEGATIVE AUXILARY OUTPUT
|
| +12V CONSTANT | |
GREEN/RED | 85 | 86 | |
OR | |||
|
| ||
30 | 87 | ||
| |||
|
| +12V CONSTANT | |
Trunk Soleniod |
| OR * | |
|
| ||
|
| ||
Dome Light |
|
| |
| * Test activation circuit in vehicle. | ||
Aux Function |
| ||
|
| ||
|
| Connect to+12V for Positive circuits | |
|
| or Ground for Negative circuits. Relay | |
|
| not included. |
Blue/Black:
This wire functions as a Negative IGNITION OUTPUT (Ground while Remote Starting) for use when connecting factory Security Bypass modules or when an additional external Ignition Relay is required for your installation. This wire can be programmed to function as an AUXILIARY OUTPUT #2 providing a momentary
5