DIESEL GLOW PLUG DELAY
This feature provides a solution for diesel vehicles without having to connect to the Glow
NOTES: This feature is OFF by default and must be programmed before use. Once this feature is turned ON, the Pink Glow plug input wire is not used. The Remote start unit will always wait the programmed time before cranking EVEN IF the glow plugs warm up first. There are 3 different Delay times available for use: 10, 20, or 30 seconds. SEE PROGRAMMING OPTION CHART, next section.
HOW TO USE THIS FEATURE:
1.See the “Programmable Options” next section and change Option #22 from "Monitor Glow Plug Light" to one of the delayed time values. (Default setting is to always monitor the PINK Glow Plug input wire.)
2.Once this option has changed the system will wait for the selected time before cranking the engine.
PROGRAMMABLE OPTIONS
You can program multiple options in one session if you start with the lowest option and continue on to higher options [if needed] without repeating steps
To Engage Option Programming:
1.Turn Key to the ON position
2.Press program / valet button 5 times, after a few seconds the unit will flash the lights 5 times.
3.Push the valet/program button [again] the number of times that corresponds to the option number desired (1 thru 30). You must get a light flash after each button press. See chart on next page for option list.
4.When you reach the desired programming level, Press button #1, #2 #3 or #4 to change the option.
5.Turn Ignition OFF, Close hood and check for changed features. Change each option individually repeating
18