Desa B350CEA Fuels Ventilation, Fresh Air Opening Requirements, 340,000 Btu/Hr, 10.5, 9755

Page 7
FUELS

FUELS

VENTILATION

Fresh Air Opening RequirementsWARNING

Use only kerosene or No. 1 fuel oil to avoid risk of fire or explosion. Never use gasoline, naphtha, paint thinners, alcohol, or other highly flammable fuels.

Do not use heavy fuels such as No. 2 fuel oil or No. 2 diesel. Using heavy fuels will result in:

clogged fuel filter and nozzle

carbon build-up on spark plug

the need of non-toxic anti-icer in fuel during very cold weather

IMPORTANT: Use a KEROSENE ONLY storage container. Be sure storage container is clean. Foreign matter such as rust, dirt, or water will cause burner control to shut down heater. Foreign matter may also require fuel system to be cleaned frequently.

340,000 Btu/Hr WARNING

Follow the minimum fresh, outside air ventilation requirements. If proper fresh, outside air ventilation is not provided, carbon monoxide poisoning can occur. Provide proper fresh, outside air ventilation before running heater.

Fresh Air Opening Requirements

 

Square

Square

Heater Size

Feet Opening

Centimeter Opening

340,000 Btu/Hr

10.5

9755

Note: If you use more than one heater, provide extra fresh air. Provide a fresh air opening of at least three square feet (2800 square cm) for each 100,000 Btu/Hr rating.

7

103807

Image 7
Contents HIGH PRESSURE PORTABLE FORCED AIR HEATER Model B350CEA Heater Size 340,000 Btu/Hr350 SIDE PFA/PV SECTION CONTENTS SAFETY INFORMATIONWARNINGS DANGERWARNINGS Continued SAFETY INFORMATIONContinued PRODUCT IDENTIFICATION UNPACKING ASSEMBLYTOOLS NEEDED Continued ASSEMBLYFigure 2 - Wheel and Handle Assembly OPERATION THEORY OF10.5 FUELS VENTILATIONFresh Air Opening Requirements 340,000 Btu/HrTo Start Heater OPERATIONTo Restart Heater STORINGTRANSPORTING, OR SHIPPING To Stop HeaterHow Often PREVENTATIVE MAINTENANCE SCHEDULEHow To POSSIBLE CAUSE PROBLEMTROUBLE- SHOOTING OBSERVEDTROUBLE- SHOOTING High VoltagePROBLEM Pump Pressure AdjustmentContinued REMEDYPROBLEM TROUBLE- SHOOTINGFigure 5 - Upper Shell Removal SERVICE PROCEDURESUpper Shell Removal Fan BladesFigure 8 - Spark Plug Gap Spark PlugNozzle Figure 7 - Spark Plug RemovalProcedure if pump is binding Pump Pressure AdjustmentPump Fuel LinesFigure 15 - Removing Tank Fuel Filter Fuel FiltersA. Tank Fuel Filter B. Pump Fuel FilterACCESSORY WIRINGDIAGRAM DESCRIPTION PARTS LISTBurner Head Assembly Motor and Pump AssemblyPARTS ILLUSTRATEDBREAKDOWN PARTS LIST NL-3004ED Rotterdam Holland Manufacturer EC CONFORMITY DECLARATIONEC CONFORMITY DECLARATION DESA Europe B.V Innsbruckweg 144, NL-3047AH PostbusPage WARRANTY SERVICE WARRANTY AND REPAIR SERVICEEQUIPMENT - LIMITED 90 DAY WARRANTY CERTIFICATE OF GENERAL