Spark Plug

Spark Plug

1.Remove upper shell (see page 14).

2.Remove spark plug wire from spark plug (see Figure 7).

3.Remove spark plug from burner head using 13/16" open- end wrench (see Figure 7).

4.Replace spark plug if damaged or heavily coated with carbon.

5.Clean and regap spark plug electrodes to .055 inch

(1.4 mm) (see Figure 8).

6.Install spark plug in burner head.

7.Attach spark plug wire to spark plug.

8.Replace upper shell.

Nozzle

1.Remove upper shell (see page 14).

2.Remove fuel line from solenoid valve using 7/16" wrench.

3.Remove spark plug wire from spark plug.

4.Remove spark plug from burner head using 13/16" open-end wrench.

5.Remove five screws using 5/16" nut-driver and remove burner head from combustion chamber.

6.Place burner head into vise and lightly tighten.

7.Carefully remove nozzle from burner head using 5/8" socket wrench (see Figure 9).

8.Inspect nozzle for damage. If damaged or clogged, replace nozzle.

9.Make sure plug is in place on burner head.

10.Replace nozzle into burner head and tighten to 80-110 inch-pounds (9.1 to 12.4 n-m).

11.Attach burner head to combus- tion chamber.

12.Install spark plug in burner head.

13.Attach spark plug wire to spark plug.

14.Attach fuel line to solenoid valve. Tighten firmly.

15.Replace upper shell.

Burner

Spark Plug

Head

 

Spark

Plug Wire

Figure 7 - Spark Plug Removal

.055 inch (1.4 mm)

Figure 8 - Spark Plug Gap

Nozzle

Plug

Spark Plug

 

Burner

Solenoid

Spark

Plug

Valve

Head

Wire

 

 

 

 

Fuel Line

 

Figure 9 - Replacing Nozzle

15

103807

Image 15
Contents Model B350CEA Heater Size 340,000 Btu/Hr HIGH PRESSURE PORTABLE FORCED AIR HEATER350 SIDE PFA/PV SECTION CONTENTS SAFETY INFORMATIONWARNINGS DANGERSAFETY INFORMATION WARNINGS ContinuedContinued UNPACKING ASSEMBLY PRODUCT IDENTIFICATIONTOOLS NEEDED ASSEMBLY ContinuedFigure 2 - Wheel and Handle Assembly OPERATION THEORY OF10.5 FUELS VENTILATIONFresh Air Opening Requirements 340,000 Btu/HrTo Start Heater OPERATIONTo Restart Heater STORINGTRANSPORTING, OR SHIPPING To Stop HeaterPREVENTATIVE MAINTENANCE SCHEDULE How OftenHow To POSSIBLE CAUSE PROBLEMTROUBLE- SHOOTING OBSERVEDTROUBLE- SHOOTING High VoltagePROBLEM Pump Pressure AdjustmentContinued REMEDYPROBLEM TROUBLE- SHOOTINGFigure 5 - Upper Shell Removal SERVICE PROCEDURESUpper Shell Removal Fan BladesFigure 8 - Spark Plug Gap Spark PlugNozzle Figure 7 - Spark Plug RemovalProcedure if pump is binding Pump Pressure AdjustmentPump Fuel LinesFigure 15 - Removing Tank Fuel Filter Fuel FiltersA. Tank Fuel Filter B. Pump Fuel FilterWIRING ACCESSORYDIAGRAM DESCRIPTION PARTS LISTBurner Head Assembly Motor and Pump AssemblyILLUSTRATED PARTSBREAKDOWN PARTS LIST NL-3004ED Rotterdam Holland Manufacturer EC CONFORMITY DECLARATIONEC CONFORMITY DECLARATION DESA Europe B.V Innsbruckweg 144, NL-3047AH PostbusPage WARRANTY SERVICE WARRANTY AND REPAIR SERVICEEQUIPMENT - LIMITED 90 DAY WARRANTY CERTIFICATE OF GENERAL