Desa B350CEA owner manual Operation, To Start Heater

Page 8
OPERATION

OPERATION

8

To Start HeaterWARNING

Review and understand the warnings in the Safety Information Section. They are needed to safely operate this heater.

To Start Heater

1.Follow all ventilation and safety information.

2.Fill fuel tank with kerosene or No. 1 fuel oil.

3.Attach fuel cap.

4.Set thermostat dial to desired temperature. Note: Thermostat setting must be higher than surrounding air temperature.

5.Plug power cord of heater into a standard 220/240 volt, 50 hertz, grounded (earthed) outlet. Use an extension cord if needed. Use only a three-wire, grounded (earthed) extension cord.

Extension Cord Wire Size Requirements

Up to 100 feet (30.5 meters) long, use 16 AWG (1.0 mm2) conductor

101 to 200 feet (30.6 to 61 meters) long, use 14 AWG (1.5 mm2) conductor 201 to 300 feet (61.1 to 91.5 meters) long, use 12 AWG (2 mm2) conductor

6.The motor will start when power cord is plugged into outlet. The heater should ignite at once. If heater does not ignite, restart heater. To restart heater, wait 60 seconds, then push in burner control reset button. Burner control reset button is at rear of heater near power cord (see Figure 4).

Note: If starting heater for first time, you may need to restart heater several times before heater ignites. You may also have to do this after taking heater out of storage.

Burner Control

Reset Button

Figure 4 - Burner Control Reset Button

103807

Image 8
Contents 350 SIDE PFA/PV Model B350CEA Heater Size 340,000 Btu/HrHIGH PRESSURE PORTABLE FORCED AIR HEATER CONTENTS SAFETY INFORMATION WARNINGSDANGER SECTIONContinued SAFETY INFORMATIONWARNINGS Continued TOOLS NEEDED UNPACKING ASSEMBLYPRODUCT IDENTIFICATION Figure 2 - Wheel and Handle Assembly ASSEMBLYContinued THEORY OF OPERATIONFUELS VENTILATION Fresh Air Opening Requirements340,000 Btu/Hr 10.5OPERATION To Start HeaterSTORING TRANSPORTING, OR SHIPPINGTo Stop Heater To Restart HeaterHow To PREVENTATIVE MAINTENANCE SCHEDULEHow Often PROBLEM TROUBLE- SHOOTINGOBSERVED POSSIBLE CAUSEHigh Voltage PROBLEMPump Pressure Adjustment TROUBLE- SHOOTINGREMEDY PROBLEMTROUBLE- SHOOTING ContinuedSERVICE PROCEDURES Upper Shell RemovalFan Blades Figure 5 - Upper Shell RemovalSpark Plug NozzleFigure 7 - Spark Plug Removal Figure 8 - Spark Plug GapPump Pressure Adjustment PumpFuel Lines Procedure if pump is bindingFuel Filters A. Tank Fuel FilterB. Pump Fuel Filter Figure 15 - Removing Tank Fuel FilterDIAGRAM WIRINGACCESSORY PARTS LIST Burner Head AssemblyMotor and Pump Assembly DESCRIPTIONBREAKDOWN ILLUSTRATEDPARTS PARTS LIST EC CONFORMITY DECLARATION EC CONFORMITY DECLARATION DESA Europe B.VInnsbruckweg 144, NL-3047AH Postbus NL-3004ED Rotterdam Holland ManufacturerPage WARRANTY AND REPAIR SERVICE EQUIPMENT - LIMITED 90 DAY WARRANTYCERTIFICATE OF GENERAL WARRANTY SERVICE