Desa B350CEA Storing, Transporting, Or Shipping, To Stop Heater, To Restart Heater, Operation

Page 9
STORING,

OPERATION

Continued

STORING,

TRANSPORTING, OR SHIPPING

To Stop Heater

TRANSPORTING, OR SHIPPING CAUTION

Never unplug heater while heater is running. Heater must go through purge cycle. The purge cycle cools the combustion chamber. Damage to heater can occur if combustion chamber is not cooled. Do not restart heater until purge cycle is complete.

1.Turn thermostat dial to lowest temperature setting. This will cause heater flame to go out. The motor will continue to run during the purge cycle. This allows the fan to cool the combustion chamber. When the purge cycle is finished, the motor will stop. Do not unplug heater until purge cycle is finished.

2.Unplug extension cord from outlet.

3.To temporarily stop heater, set thermostat at a temperature lower than air around heater. Heater will cycle back on if air temperature around heater matches thermostat setting.

To Restart Heater

To Stop Heater CAUTION

Do not restart heater until purge cycle is finished. The purge cycle cools the combustion chamber.

1.Wait until purge cycle is finished after stopping heater.

2.Repeat steps under To Start Heater, page 8.

Note: If shipping, transport companies require fuel tanks to be empty.

1.Drain all fuel from fuel filters, fuel lines, and pump (see Fuel Filters [Tank Fuel Filter], page 17).

2.Clean and flush fuel filter and canister attached to fuel pump (see Fuel Filters [Pump Fuel Filter], page 17).

3.Remove drain plug and drain fuel tank.

4.Replace drain plug.

5.Add one gallon (four liters) of clean kerosene to fuel tank.

6.Attach fuel cap.

7.Move the heater forwards and backwards to stir fuel.

8.Remove drain plug and drain fuel tank.

9.Replace drain plug.

10.Add two gallons (eight liters) of clean kerosene or No. 1 fuel oil to fuel tank.

11.Replace fuel cap.

12.Operate heater for 5 minutes (see Operation, page 8).

13.Stop heater and let cool completely.

14.Remove drain plug and drain fuel tank.

15.Replace drain plug.

16.Properly dispose of old and dirty fuel.

17.Store heater in a dry location. Make sure storage place is free of dust and corrosive fumes.

IMPORTANT: Do not store kerosene over summer months for use during next

 

heating season. Using old fuel could damage heater.

9

 

103807

Image 9
Contents Model B350CEA Heater Size 340,000 Btu/Hr HIGH PRESSURE PORTABLE FORCED AIR HEATER350 SIDE PFA/PV WARNINGS CONTENTS SAFETY INFORMATIONDANGER SECTIONSAFETY INFORMATION WARNINGS ContinuedContinued UNPACKING ASSEMBLY PRODUCT IDENTIFICATIONTOOLS NEEDED ASSEMBLY ContinuedFigure 2 - Wheel and Handle Assembly OPERATION THEORY OFFresh Air Opening Requirements FUELS VENTILATION340,000 Btu/Hr 10.5To Start Heater OPERATIONTRANSPORTING, OR SHIPPING STORINGTo Stop Heater To Restart HeaterPREVENTATIVE MAINTENANCE SCHEDULE How OftenHow To TROUBLE- SHOOTING PROBLEMOBSERVED POSSIBLE CAUSEPROBLEM High VoltagePump Pressure Adjustment TROUBLE- SHOOTINGPROBLEM REMEDYTROUBLE- SHOOTING ContinuedUpper Shell Removal SERVICE PROCEDURESFan Blades Figure 5 - Upper Shell RemovalNozzle Spark PlugFigure 7 - Spark Plug Removal Figure 8 - Spark Plug GapPump Pump Pressure AdjustmentFuel Lines Procedure if pump is bindingA. Tank Fuel Filter Fuel FiltersB. Pump Fuel Filter Figure 15 - Removing Tank Fuel FilterWIRING ACCESSORYDIAGRAM Burner Head Assembly PARTS LISTMotor and Pump Assembly DESCRIPTIONILLUSTRATED PARTSBREAKDOWN PARTS LIST EC CONFORMITY DECLARATION DESA Europe B.V EC CONFORMITY DECLARATIONInnsbruckweg 144, NL-3047AH Postbus NL-3004ED Rotterdam Holland ManufacturerPage EQUIPMENT - LIMITED 90 DAY WARRANTY WARRANTY AND REPAIR SERVICECERTIFICATE OF GENERAL WARRANTY SERVICE