Chief Manufacturing CM2 installation instructions Lift Column Bearing Adjustment

Page 15

Installation Instructions

CM2

Lift Column Bearing Adjustment

The upper and lower lift columns are aligned using two lift bearings, one upper and one lower.

Bearing adjustment is pre-set at the factory, however, there may be times when it is required to make slight adjustments in bearing tightness to eliminate excess play in lift columns or noise.

WARNING: OVERTENSIONING CAN LEAD TO DAMAGE TO EQUIPMENT! DO NOT overadjust!

IMPORTANT ! : Display should be installed on mount prior to performing lift colimn bearing adjustment!

To adjust lift column bearings:

1.Determine if it is the upper or lower lift column that requires adjustment.

2.Using a hex wrench, turning in small increments evenly across all adjustment screws, loosen or tighten adjustment screws.

3.Run Display to fully up, and fully down position and verify proper lift column movement.

4.Repeat steps 1 through 3 until desired lift column movement is achieved.

Upper Lift Column Bearing Adjustment Points

Upper Lift Column Bearing Adjustment Points (two front and two rear)

Figure 28

15

Image 15
Contents CM2 Important Warnings and Cautions Contents Open-Ended Wrench Adjusting Faceplate Location Power Requirements and WiringPre-Installation Configuration and Adjustments Configuring the Mount for the DisplayIf more than 2 of faceplate adjustment is required Display Installation For clarity Shelf Height AdjustmentDetermining Minimum I.D. of Furniture Cable Installation and Routing CM2 Side Cover Mount Installation Display Travel Adjustment Lift Cable Tension AdjustmentDrive Belt Tension Adjustment Lift Column Bearing Adjustment Remote Control Function Normal Operating ModeIR System Code IR-SE15 Control Codes IR-SE15 ProgrammingIR-SC33a Control Features Carrier Frequency 38KHz IR-SC33a ProgrammingSystem Code 6E Serial Communications Connecctions to be made to 9 pin connector as followsError Message Table Motor Control Hardware Information CM2 Hardware ReferenceCM2 Connectors and Switches Dry Contact Closures CM2 Interface Board Hardware InformationExtend Error Input Extend Retract with Single SwitchVoltage Sense External Power Source Voltage Sense Internal 24V DC Power SourceRetract Error Input Extend Limit OptionRetract Limit Option SW1 Connector and Switch AssignmentsTroubleshooting CM2 +86-755-8996 +86-755-8996 9226 8996 9236 8996