Chief Manufacturing CM2 installation instructions Cable Installation and Routing

Page 10

CM2

Installation Instructions

Cable Installation and Routing

The CM2 has an integrated cable management system that allows cables to be automatically "fed out" as the lift raises, and "reeled in" as the lift lowers while maintaining constant cable tension.

IMPORTANT ! : The CM2 requires minimum cable lengths of 8 feet from display through lower mount.

To install cables:

1.Remove two screws securing cable guide side cover.

2.Set screws aside for reuse. (See figure 17)

1

x2

Cable Guide

Side Cover

Figure 17

3.Slide cable guide side cover away from mount and carefully set aside.

Cable Guide

Side Cover

3

Figure 18

4.Loosen six cable clamps. (See figure 19)

5.Route cable(s) down through upper cable clamp. (See figure 19) and (See figure 20)

IMPORTANT ! : Leave enough cable length available above upper cable clamp to allow the routing and tie-down of cables between upper cable clamp and display.

10

Image 10
Contents CM2 Important Warnings and Cautions Contents Open-Ended Wrench Configuring the Mount for the Display Power Requirements and WiringPre-Installation Configuration and Adjustments Adjusting Faceplate LocationIf more than 2 of faceplate adjustment is required Display Installation Shelf Height Adjustment For clarityDetermining Minimum I.D. of Furniture Cable Installation and Routing CM2 Side Cover Mount Installation Lift Cable Tension Adjustment Display Travel AdjustmentDrive Belt Tension Adjustment Lift Column Bearing Adjustment Normal Operating Mode Remote Control FunctionIR System Code IR-SE15 Programming IR-SE15 Control CodesIR-SC33a Programming IR-SC33a Control Features Carrier Frequency 38KHzSystem Code 6E Connecctions to be made to 9 pin connector as follows Serial CommunicationsError Message Table CM2 Hardware Reference Motor Control Hardware InformationCM2 Connectors and Switches CM2 Interface Board Hardware Information Dry Contact ClosuresVoltage Sense Internal 24V DC Power Source Extend Retract with Single SwitchVoltage Sense External Power Source Extend Error InputExtend Limit Option Retract Error InputRetract Limit Option Connector and Switch Assignments SW1Troubleshooting CM2 +86-755-8996 9226 8996 9236 8996 +86-755-8996