Chief Manufacturing CM2 installation instructions Error Message Table

Page 21

Installation Instructions

CM2

Address Description:

Multiple Chief devices can be used on the same network by setting each device to a different address. Note: All units ship with a default address of 0

Address Table:

Addresses are set using dipswitches located next to power inlet on mount. (See figure 32)

Switch # 6

 

Switch # 7

Switch # 8

Address

 

 

 

 

 

 

 

 

 

OFF

 

 

OFF

 

OFF

00

 

 

 

 

 

 

 

 

 

ON

 

 

OFF

 

OFF

01

 

 

 

 

 

 

 

 

 

OFF

 

 

ON

 

OFF

02

 

 

 

 

 

 

 

 

 

ON

 

 

ON

 

OFF

03

 

 

 

 

 

 

 

 

 

OFF

 

 

OFF

 

ON

04

 

 

 

 

 

 

 

 

 

ON

 

 

OFF

 

ON

05

 

 

 

 

 

 

 

 

 

OFF

 

 

ON

 

ON

06

 

 

 

 

 

 

 

 

 

ON

 

 

ON

 

ON

07

 

 

 

 

 

 

 

 

 

Status Table:

 

 

 

 

 

 

Status is a 4 character hex representation of a 16 bit value

 

 

 

 

 

 

 

 

 

 

Bit

1

0

 

Description

 

 

 

 

 

 

 

 

 

0

TRUE

FALSE

In Home Position?

 

 

 

 

 

 

 

 

1

TRUE

FALSE

Move in Progress?

 

 

 

 

 

 

 

 

2

TRUE

FALSE

Network Operation in Progress?

 

 

 

 

 

 

 

 

3

TRUE

FALSE

Parameter Changes Enabled?

 

 

 

 

 

 

 

 

4

TRUE

FALSE

Network Command Error?

 

 

 

 

 

 

 

 

 

5

-

-

 

Not Used - Permanently @ 0

 

 

 

 

 

 

 

 

 

6

-

-

 

Not Used - Permanently @ 0

 

 

 

 

 

 

 

 

 

7

-

-

 

Not Used - Permanently @ 0

 

 

 

 

 

 

 

 

8

TRUE

FALSE

At Extend Limit

 

 

 

 

 

 

 

 

9

TRUE

FALSE

At Retract Limit

 

 

 

 

 

 

 

 

 

10

-

-

 

Not Used - Permanently @ 0

 

 

 

 

 

 

 

 

 

11

-

-

 

Not Used - Permanently @ 0

 

 

 

 

 

 

 

 

 

12

-

-

 

Not Used - Permanently @ 0

 

 

 

 

 

 

 

 

 

13

-

-

 

Not Used - Permanently @ 0

 

 

 

 

 

 

 

 

 

14

-

-

 

Not Used - Permanently @ 0

 

 

 

 

 

 

 

 

 

15

-

-

 

Not Used - Permanently @ 0

 

 

 

 

 

 

 

 

 

 

Example:

Fully retracted, parameter changes disabled, no errors, not moving, in home position. 0, 0, 0, 0, 0, 0, 1, 0, 0, 0, 0, 0, 0, 0, 0, 1

Value returned as status: 0201 (hex)

Errors:

If no response message is received, the device does not exist on the network, or there was an error during message transmission See Error Message Table

Error Message Table:

0x01

Command Not Supported

Returned when a device does not support the command sent

 

 

 

0x02

Index Error

Returned when the index value sent is out or range for the device

 

 

 

0x03

Value Error

Returned when the data value sent is out of range for the device

 

 

 

0x04

Message Length Error

Returned when the length of the command message is incorrect for the command code

 

 

 

0x05

Write Protect Error

Returned when parameter changes are attempted without first enabling parameter changes

 

 

 

21

Image 21
Contents CM2 Important Warnings and Cautions Contents Open-Ended Wrench Pre-Installation Configuration and Adjustments Power Requirements and WiringConfiguring the Mount for the Display Adjusting Faceplate LocationIf more than 2 of faceplate adjustment is required Display Installation For clarity Shelf Height AdjustmentDetermining Minimum I.D. of Furniture Cable Installation and Routing CM2 Side Cover Mount Installation Display Travel Adjustment Lift Cable Tension AdjustmentDrive Belt Tension Adjustment Lift Column Bearing Adjustment Remote Control Function Normal Operating ModeIR System Code IR-SE15 Control Codes IR-SE15 ProgrammingIR-SC33a Control Features Carrier Frequency 38KHz IR-SC33a ProgrammingSystem Code 6E Serial Communications Connecctions to be made to 9 pin connector as followsError Message Table Motor Control Hardware Information CM2 Hardware ReferenceCM2 Connectors and Switches Dry Contact Closures CM2 Interface Board Hardware InformationVoltage Sense External Power Source Extend Retract with Single SwitchVoltage Sense Internal 24V DC Power Source Extend Error InputRetract Error Input Extend Limit OptionRetract Limit Option SW1 Connector and Switch AssignmentsTroubleshooting CM2 +86-755-8996 +86-755-8996 9226 8996 9236 8996