Chief Manufacturing CM2 installation instructions Serial Communications

Page 20

CM2

Installation Instructions

Serial Communications

NOTE: Check with the appropriate automation system vendor for available drivers and/or software for any external devices. Notes:

[PR] = Product ID (CM2 = 02)

[AD] = Address (see address description & table) [CR] = ASCII Carriage Return

[CH] = Check Code

[ST] = Status (see status table)

Connecctions to be made to 9 pin connector as follows:

RS-485 REF

 

Pin 7

 

 

 

 

RS-485

+

 

Pin 8

 

 

 

 

RS-485

-

 

Pin 9

 

 

 

Communication parameters as specified in ANSI TIA/EIA-485-A:

 

 

 

Baud Rate:

9600

 

 

 

 

Data Length:

8 Bits

 

 

 

 

 

Parity:

 

None

 

 

 

 

Stop Bit:

1

 

 

 

 

Flow Control:

None

 

 

 

 

 

Command Table:

Action:

Command:

Expected Response:

 

 

 

Extend

>[PR][AD]0E[CH][

<[ST][CH][CR] & unit should Extend

 

CR]

 

 

 

 

Retract

>[PR][AD]10[CH][

<[ST][CH][CR] & unit should Retract

 

CR]

 

 

 

 

Cancel Move

>[PR][AD]03[CH][

<[ST][CH][CR] & unit should Stop

 

CR]

 

 

 

 

Poll for Status

>[PR][AD]01[CH][

<[ST][CH][CR]

 

CR]

 

 

 

 

Get Model #

>[PR][AD]66[CH][

<(unit model #)[CH][CR]

 

CR]

 

 

 

 

Get Operation

>[PR][AD]64[CH][

<[ST](4 digit hex operation count)[CH][CR]

Count

CR]

 

 

 

 

Get Software

>[PR][AD]67[CH][

<[ST](4 digit revision level)[CH][CR]

Revision

CR]

 

 

 

 

Get Serial #

>[PR][AD]68[CH][

<(10 digit unit serial #)[CH][CR]

 

CR]

 

 

 

 

20

Image 20
Contents CM2 Important Warnings and Cautions Contents Open-Ended Wrench Power Requirements and Wiring Pre-Installation Configuration and AdjustmentsConfiguring the Mount for the Display Adjusting Faceplate LocationIf more than 2 of faceplate adjustment is required Display Installation Shelf Height Adjustment For clarityDetermining Minimum I.D. of Furniture Cable Installation and Routing CM2 Side Cover Mount Installation Drive Belt Tension Adjustment Display Travel AdjustmentLift Cable Tension Adjustment Lift Column Bearing Adjustment Normal Operating Mode Remote Control FunctionIR System Code IR-SE15 Programming IR-SE15 Control CodesSystem Code 6E IR-SC33a Control Features Carrier Frequency 38KHzIR-SC33a Programming Connecctions to be made to 9 pin connector as follows Serial CommunicationsError Message Table CM2 Hardware Reference Motor Control Hardware InformationCM2 Connectors and Switches CM2 Interface Board Hardware Information Dry Contact ClosuresExtend Retract with Single Switch Voltage Sense External Power SourceVoltage Sense Internal 24V DC Power Source Extend Error InputRetract Limit Option Retract Error InputExtend Limit Option Connector and Switch Assignments SW1Troubleshooting CM2 +86-755-8996 9226 8996 9236 8996 +86-755-8996