Chief Manufacturing CM2 installation instructions IR-SE15 Programming, IR-SE15 Control Codes

Page 18

CM2

Installation Instructions

IR-SE15 Programming

IR-SE15 Control Features:

Carrier Frequency:38KHz

Protocol:NEC - Full Repeat

System Code(s):6E (Default) - Multiple Codes Selected via Key-Press (see below)

Table 1-2: IR-SE15 Control Codes

Key Number

Key Name

Hex Code

 

 

 

1

HOME

02

 

 

 

2

SAVE

1A

 

 

 

3

UP

07

 

 

 

4

LEFT

09

 

 

 

5

STOP

0A

 

 

 

6

RIGHT

0B

 

 

 

7

DOWN

0D

 

 

 

8

PRESET 1

12

 

 

 

10

PRESET 2

13

 

 

 

12

PRESET 3

14

 

 

 

To Change System Code:

1.Press and Release Key 3 + 7 (Enter Setup Mode)

2.Press and Release Key 8

3.Press and Release Key 10

4.Press and Release Key 12 - LED Blinks Twice <Quick>

5.Select System Code - See Table Below

6.Press and Release Key 2 - LED Blinks 4 times <Quick> (Exit Setup Mode)

Table 1-3:

System

Press +

Code

Release

 

 

6E (Default)

8

 

 

E1

8,8,8,8

 

 

E2

10

 

 

E3

10,8

 

 

E4

10,8,8

 

 

E5

10,8,8,8

 

 

E6

10,8,8,8,8

 

 

E7

12

 

 

1

 

2

 

3

 

4

5

6

 

7

 

 

8

 

 

10

 

 

12

 

Figure 31

18

Image 18
Contents CM2 Important Warnings and Cautions Contents Open-Ended Wrench Configuring the Mount for the Display Power Requirements and WiringPre-Installation Configuration and Adjustments Adjusting Faceplate LocationIf more than 2 of faceplate adjustment is required Display Installation Shelf Height Adjustment For clarityDetermining Minimum I.D. of Furniture Cable Installation and Routing CM2 Side Cover Mount Installation Display Travel Adjustment Lift Cable Tension AdjustmentDrive Belt Tension Adjustment Lift Column Bearing Adjustment Normal Operating Mode Remote Control FunctionIR System Code IR-SE15 Programming IR-SE15 Control CodesIR-SC33a Control Features Carrier Frequency 38KHz IR-SC33a ProgrammingSystem Code 6E Connecctions to be made to 9 pin connector as follows Serial CommunicationsError Message Table CM2 Hardware Reference Motor Control Hardware InformationCM2 Connectors and Switches CM2 Interface Board Hardware Information Dry Contact ClosuresVoltage Sense Internal 24V DC Power Source Extend Retract with Single SwitchVoltage Sense External Power Source Extend Error InputRetract Error Input Extend Limit OptionRetract Limit Option Connector and Switch Assignments SW1Troubleshooting CM2 +86-755-8996 9226 8996 9236 8996 +86-755-8996