Heatiator I80 owner manual Maintenance Task List, Chimney Fire, When cleaning glass door, Clean

Page 42

CAUTION

Handle glass assembly with care.

When cleaning glass door:

Avoid striking, scratching or slamming glass.

Do NOT use abrasive cleaners.

Use a hard water deposit glass cleaner on white film.

Do NOT clean glass when it is hot.

WARNING

Fire Risk

Do not use chimney cleaners or flame colorants in your fireplace.

Will corrode chimney.

WARNING

Asphyxiation Risk

Fire Risk

Annual inspection by qualified technician recommended.

Check:

Condition of doors, surrounds and fronts

Condition of glass and glass assembly

Obstructions of combustion and ventilation air

Gas connections and fittings (if present)

Obstructions of termination cap

Refractory panels

Clean:

Glass

Air passageways, grilles

D. Maintenance Task List

Inspect

 

Maintenance Tasks

Screens

1.

Assess condition of screen and replace as necessary. Screens are required.

 

 

 

 

2.

Verify maintenance of proper clearance to combustible household objects.

 

 

 

Glass Doors

1.

Inspect glass panels for cracks. Replace if this condition is present.

 

 

 

 

2.

Confirm there is no damage to glass or glass frame. Replace as necessary.

 

 

 

 

3.

Clean glass using a non-abrasive cleaner such as Brasso©.

 

 

 

Circulation Compartment

1.

Remove any foreign objects.

 

 

 

 

2.

Verify unobstructed air circulation.

 

 

 

Firebox

1.

Inspect condition of refractory. Replace if crumbly, deteriorated, or if cracks exceed 1/4 in. (6 mm).

 

 

 

Chimney

1.

Inspect for blockage or obstruction such as bird nests, leaves, etc.

 

 

 

 

2.

Confirm that termination cap remains clear and unobstructed by plants, etc.

 

 

 

 

3.

Verify that termination cap clearance to subsequent construction (building additions) has been maintained.

 

 

 

 

4.

Inspect for corrosion or separation.

 

 

 

 

5.

Verify weather stripping, sealing and flashing remain intact.

 

 

 

 

6.

Inspect for creosote and remove as needed. (See Sections 10 and 11)

 

 

 

Grate

1.

If grate burns out, it should be replaced only with the grate specified on the rating plate and in the replacement

 

 

parts list for this fireplace.

E. Chimney Fire

In the event of a chimney fire:

Have the chimney and adjacent structure inspected by qualified professionals. Hearth & Home Technologies recommends that NFI or CSIA certified professionals, or technicians under the direction of certified professionals, conduct a minimum of an NFPA 211 Level 2 inspection of the chimney.

Replace components of the chimney and fireplace as specified by the professionals.

Ensure all joints are properly engaged and the chimney is properly secured.

A chimney fire can permanently damage your chimney sys- tem. Failure to replace damaged components and make proper repairs creates risk of fire.

42

Heatilator • I80 CAN-US4013-203 Rev F • 04/08

Image 42
Contents Hot glass will cause burns Fire RiskListing Label Information/Location GrateNumber Table of Contents Listing and Code Approvals Appliance CertificationNot intended for use as a primary heat source Negative Pressure Design and Installation ConsiderationsGetting Started Asphyxiation RiskMarginal Location Typical Fireplace System Typical Fireplace SystemTools and Supplies Needed Inspect Fireplace and ComponentsFire Risk Explosion Risk Framing and Clearances Selecting Fireplace LocationClearances Clearances to Combustible MaterialsSidewalls/Surrounds Frame the FireplaceConstruct the Chase Chimney RequirementsFire Risk Sharp Edges Asphyxiation Risk Installation of Fireplace¨ A. Install the Outside Air Kit Risk of Smoke SpillageAttic insulation shield Must be used to keep Install the Refractory Secure the FireplacePosition the Fireplace Grate Brackets Grate Bracket Place the Protective Metal Hearth Strips Level the FireplaceChimney Assembly Height of Chimney Components Using Offsets/Returns Chimney Offset/ReturnInstall the Ceiling Firestops Assemble the Chimney SectionsInstall the Attic Insulation Shield Prepare Attic Insulation ShieldDouble-check the Chimney Assembly Secure the ChimneyComplete the Enclosure Chimney TerminationChimney Termination Requirements See Figure Mark the Exit Point of the Roof Install the Roof FlashingInstall the Chimney Air Kit required in Canada Cut Out the Hole in the RoofInstall the Termination Cap Chase TopInstalling an ST1175 or ST475 Square Termination Cap Accessories Gas Log/Lighter ProvisionsGas Code, Ansi Z223.1 Finishing Hearth ExtensionCAT. # Finishing Material Combustible MaterialNon-Combustible Material Mantel Glass DoorsNFPA211 Operating Instructions General InformationFlue Damper Outside AirClear Space Near the Fireplace FirescreenFirewood GrateWood Fuel MoistureStarting a Fire Troubleshooting Understanding Vent ProblemsSolutions Diagnostics and Problem SolvingDiagnostic Questions Can’t get a good fire going. What am I doing wrong?fireplace burns the wood too fast. What can I do? Disposal of Ashes Maintenance and Servicing the FireplaceChimney Inspection/Cleaning Firebox RefractoryClean Maintenance Task ListWhen cleaning glass door Chimney FireFireplace Dimensions Reference MaterialsFireplace Components Catalog # DescriptionChimney Components Catalog #15-1/4 387 mm Catalog # European Copper Caps Available in US only Woodburning Termination Cap ¨ D. Service Parts Heatilator I80 CAN-US 4013-203 Rev F 04/08Description of Part Serial # Cutoff I80HThis page intentionally left blank This page intentionally left blank This page intentionally left blank Limited Warranty Contact Information

I80 specifications

The Heatiator I80 is a cutting-edge fireplace insert designed to provide efficient heating while enhancing the aesthetics of any living space. Combining modern technology with elegant design, the I80 is perfect for homeowners looking to experience the warmth and ambiance of a fire without sacrificing efficiency.

One of the standout features of the Heatiator I80 is its advanced heating technology. With a high-efficiency rating, this insert maximizes heat output while minimizing fuel consumption. The I80 is designed to utilize either wood or gas, offering versatility for users based on their preference and availability. The dual-fuel capability allows for easy adaptation to different conditions, providing comfort and warmth throughout the year.

The I80 incorporates a patented airflow system that improves heat circulation within the home. This innovative system distributes warm air efficiently, ensuring that every corner of the room feels cozy. Additionally, the insert comes with an adjustable fan that can be tailored to suit user preferences, allowing for customized heating levels based on the desired atmosphere.

Another impressive characteristic of the Heatiator I80 is its sleek design. The fireplace insert features a large viewing window, crafted from high-temperature tempered glass, which not only showcases the mesmerizing flames but also complements contemporary interior decor. The minimalist design is available in various finishes, enabling homeowners to choose an option that best fits their style.

Safety is a paramount concern, and the I80 comes equipped with several safety features. It includes a built-in safety shut-off mechanism that engages if the temperature rises beyond safe levels, ensuring peace of mind for users. Moreover, the unit is designed with an outer casing that remains cool to the touch, making it suitable for homes with children and pets.

Installation of the Heatiator I80 is straightforward, thanks to its flexible venting options. Whether retrofitting an existing fireplace or installing a new insert, the adaptability of the I80 accommodates various configurations, allowing for hassle-free integration into any home.

In conclusion, the Heatiator I80 stands out due to its combination of high efficiency, aesthetic appeal, and advanced safety features. With its ability to deliver warmth, ambiance, and design compatibility, it represents an exceptional option for those seeking to enhance their living space while enjoying the comfort of a modern fireplace insert.