Heatiator I80 owner manual European Copper Caps Available in US only

Page 48

European Copper Caps (Available in US only)

21 in.

(533 mm)

18-1/4 in. (464 mm)

47-3/4 in.

(1213 mm)41-1/8 in.

(1045 mm)

20-3/4 in. (527 mm)

38-5/8 in.

(981 mm)

 

24 in.

 

 

 

 

20 in.

 

 

 

 

 

 

 

 

 

 

 

(508 mm)

(610 mm)

 

 

 

 

 

CT11-King

CT11-Queen

16in.

(406 mm)

38-3/8 in.

(975 mm)

16 in. (406 mm)

CT11-Knight

20 in.

(508 mm)

CT11-Bishop

21 in.

(533 mm)

25-3/4 in.

(654 mm)

20-5/8 in. (524 mm)

CT11-Pawn

48

Heatilator • I80 CAN-US4013-203 Rev F • 04/08

Image 48
Contents Hot glass will cause burns Fire RiskListing Label Information/Location GrateNumber Table of Contents Listing and Code Approvals Appliance CertificationNot intended for use as a primary heat source Design and Installation Considerations Getting StartedNegative Pressure Asphyxiation RiskMarginal Location Typical Fireplace System Typical Fireplace SystemTools and Supplies Needed Inspect Fireplace and ComponentsFire Risk Explosion Risk Framing and Clearances Selecting Fireplace LocationClearances Clearances to Combustible MaterialsSidewalls/Surrounds Frame the FireplaceConstruct the Chase Chimney RequirementsInstallation of Fireplace ¨ A. Install the Outside Air KitFire Risk Sharp Edges Asphyxiation Risk Risk of Smoke SpillageAttic insulation shield Must be used to keep Install the Refractory Secure the FireplacePosition the Fireplace Grate Brackets Grate Bracket Place the Protective Metal Hearth Strips Level the FireplaceChimney Assembly Height of Chimney Components Using Offsets/Returns Chimney Offset/ReturnInstall the Ceiling Firestops Assemble the Chimney SectionsInstall the Attic Insulation Shield Prepare Attic Insulation ShieldDouble-check the Chimney Assembly Secure the ChimneyComplete the Enclosure Chimney TerminationChimney Termination Requirements See Figure Install the Roof Flashing Install the Chimney Air Kit required in CanadaMark the Exit Point of the Roof Cut Out the Hole in the RoofInstall the Termination Cap Chase TopInstalling an ST1175 or ST475 Square Termination Cap Accessories Gas Log/Lighter ProvisionsGas Code, Ansi Z223.1 Finishing Hearth ExtensionCAT. # Finishing Material Combustible MaterialNon-Combustible Material Mantel Glass DoorsNFPA211 Operating Instructions General InformationOutside Air Clear Space Near the FireplaceFlue Damper FirescreenGrate Wood FuelFirewood MoistureStarting a Fire Troubleshooting Understanding Vent ProblemsDiagnostics and Problem Solving Diagnostic QuestionsSolutions Can’t get a good fire going. What am I doing wrong?fireplace burns the wood too fast. What can I do? Maintenance and Servicing the Fireplace Chimney Inspection/CleaningDisposal of Ashes Firebox RefractoryMaintenance Task List When cleaning glass doorClean Chimney FireFireplace Dimensions Reference MaterialsFireplace Components Catalog # DescriptionChimney Components Catalog #15-1/4 387 mm Catalog # European Copper Caps Available in US only Woodburning Termination Cap ¨ D. Service Parts Heatilator I80 CAN-US 4013-203 Rev F 04/08Description of Part Serial # Cutoff I80HThis page intentionally left blank This page intentionally left blank This page intentionally left blank Limited Warranty Contact Information

I80 specifications

The Heatiator I80 is a cutting-edge fireplace insert designed to provide efficient heating while enhancing the aesthetics of any living space. Combining modern technology with elegant design, the I80 is perfect for homeowners looking to experience the warmth and ambiance of a fire without sacrificing efficiency.

One of the standout features of the Heatiator I80 is its advanced heating technology. With a high-efficiency rating, this insert maximizes heat output while minimizing fuel consumption. The I80 is designed to utilize either wood or gas, offering versatility for users based on their preference and availability. The dual-fuel capability allows for easy adaptation to different conditions, providing comfort and warmth throughout the year.

The I80 incorporates a patented airflow system that improves heat circulation within the home. This innovative system distributes warm air efficiently, ensuring that every corner of the room feels cozy. Additionally, the insert comes with an adjustable fan that can be tailored to suit user preferences, allowing for customized heating levels based on the desired atmosphere.

Another impressive characteristic of the Heatiator I80 is its sleek design. The fireplace insert features a large viewing window, crafted from high-temperature tempered glass, which not only showcases the mesmerizing flames but also complements contemporary interior decor. The minimalist design is available in various finishes, enabling homeowners to choose an option that best fits their style.

Safety is a paramount concern, and the I80 comes equipped with several safety features. It includes a built-in safety shut-off mechanism that engages if the temperature rises beyond safe levels, ensuring peace of mind for users. Moreover, the unit is designed with an outer casing that remains cool to the touch, making it suitable for homes with children and pets.

Installation of the Heatiator I80 is straightforward, thanks to its flexible venting options. Whether retrofitting an existing fireplace or installing a new insert, the adaptability of the I80 accommodates various configurations, allowing for hassle-free integration into any home.

In conclusion, the Heatiator I80 stands out due to its combination of high efficiency, aesthetic appeal, and advanced safety features. With its ability to deliver warmth, ambiance, and design compatibility, it represents an exceptional option for those seeking to enhance their living space while enjoying the comfort of a modern fireplace insert.