DANGER:Tefollowingworkistobeperformedonlybyalicensedelectrician. | ishazardous |
| ||
| TROUBLESHOOTING |
|
| |
voltagewhichcanshock,burnorkill.Turnpoweroff.UnplugpowercordbeforeservicorTherecleaning. |
| |||
! | ! | |||
|
|
|
|
|
|
|
|
|
|
Problem: | Probable Cause: | Solution: |
|
|
|
|
|
|
|
Unit will not run (heater | Power cord is not plugged in | Plug in power cord |
|
|
and fan are off) |
|
|
|
|
|
|
|
| |
| Circuit breaker is tripped | Call a licensed electrician |
| |
|
|
|
| |
| No power at outlet | Call a licensed electrician |
| |
|
|
|
| |
| Defective power cord or switch | Call a licensed service agency or a |
| |
|
| licensed electrician |
|
|
|
|
|
| |
Compartment too cold | Check door | Instruct user to keep door closed |
| |
|
|
| ||
| Poor door seal | Check door seal and replace if necessary | ||
|
|
|
| |
| Thermostat setting is too low | Turn thermostat knob to a warmer |
| |
|
| position. This should be done one |
| |
|
| increment at a time until a satisfactory |
| |
|
| temperature is obtained |
| |
|
|
|
| |
| Defective thermostat | Check thermostat. If necessary, call a |
| |
|
| licensed service agency or a licensed |
| |
|
| electrician |
|
|
|
|
| ||
Compartment too hot | Thermostat setting is too high | Turn thermostat knob to a cooler position. | ||
|
| This should be done one increment at a | ||
|
| time until a satisfactory temperature is |
| |
|
| obtained |
|
|
|
|
|
| |
| Defective thermostat | Check thermostat. If necessary, call a |
| |
|
| licensed service agency or a licensed |
| |
|
| electrician |
|
|
|
|
|
|
|
No humidity | No water in pan | Add hot water |
|
|
|
|
|
|
|
| Selector Switch on heat | Switch to Proof Mode |
|
|
|
|
| ||
| Humidity thermostat set too low | Adjust thermostat (usually 1/4 to 1/3 of full | ||
|
| range) |
|
|
|
|
|
|
|
11