Desa Tech CCL3018NR Operating Heater, For Your Safety Read Before Lighting, Lighting Instructions

Page 19

OPERATING HEATER

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result causing property damage, per- sonal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service tech- nician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a quali- fied service technician to inspect the appli- ance and to replace any part of the control system and any gas control which has been under water.

LIGHTING

INSTRUCTIONS

WARNING:

If fireplace has glass doors, never operate this heater with glass doors closed. If you op- erate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Make sure there are no obstructions across opening of fireplace.

You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater.

NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell. Orange flame will also be present. Open damper or win- dow to vent smell. This will only last a few hours.

Note: Home owners generally prefer to oper- ate their heater with the chimney damper closed. This will put all the heat into the room. However, there may be times you will desire the full flames of the HI heat setting but will find the heat output excessive. You can open the chimney damper (if you have one) fully or partially to release some of the heat.

WARNING: Damper handle will be hot if heater has been running.

1.STOP! Read the safety information, col- umn 1.

2.Make sure equipment shutoff valve is fully open.

3.Set selector switch in the OFF position.

WARNING: Burners will come on automatically within one minute when the selector switch is in the ON position after the pilot is lit.

111161-01D

www.desatech.com

19

Image 19
Contents Yellow Flame Model Shown CCL3930NR, CCL3930PR CCL3930NRA, CCL3930PRATable of Contents Safety Information Local Codes Unpacking Product FeaturesRemote Control Accessories Product IdentificationConfined Space and Unconfined Space Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Unusually Tight ConstructionVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Check GAS Type InstallationLog Installation and Clearances Vent-Free Operation OnlyMantel Clearances If Using MantelFloor Clearances Installing Damper Clamp Accessory for VentedInstallation Items Needed Installing Heater Base AssemblyExternal Regulator With Vent Pointing Down Connecting to GAS SupplyTest Pressures In Excess Of 1/2 Psig 3.5 kPa Checking GAS ConnectionsTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Installing Remote Receiver UnitInstalling 9-Volt Battery in Receiver Installing Wireless HAND- Held Remote Control AccessoryInstalling Front Log #1 CCL3930PR/NR Shown Installing LogsInstalling Crossover Log #4 CCL3930PR/NR Shown Operating Heater For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To Appliance Thermostat Series Model Cghrctb Manual Lighting ProcedureOptional HAND-HELD Remote Operation ON/OFF Series Model CghrcbPilot Flame Pattern Inspecting BurnersMain Burner Cleaning MaintenanceBurner Injector Holder and Pilot AIR Inlet Hole LogsObserved Problem Possible Cause Remedy TroubleshootingPress in control knob fully See Cleaning and Mainte Gas leak. See Warning Models CCL3018PR, CCL3018PRA, CCL3018NR, and CCL3018NRA Illustrated Parts BreakdownParts List Models Remote Receiver CHL Only When Gas Pressure Is Too Low SpecificationsWiring Diagram Technical Service Service HintsParts Central Replacement PartsParts Under Warranty Parts not Under WarrantyFireplace Hood Receiver and HAND-HELD Remote Control KIT Cghrcb SeriesCleaning KIT CCK Equipment Shutoff Valve GA5010111161-01D Keep this Warranty Warranty InformationLimited Warranty Comfort Glow VENT-FREE GAS LOG Heaters

CCL3018NR, CCL3018PR, CCL3018NRA, CCL3018PRA, CCL3924NR, CCL3924PR, CCL3924NRA, CCL3924PRA, CHL3924NR, CHL3924PR, CCL3930NR, CCL3930PR, CCL3930NRA, CCL3930PRA, CCL3018NR, CCL3930PRA specifications

Desa Tech has established a reputation for engineering high-performance heating solutions, and its range of products, including models such as CCL3018NR, CCL3930PRA, CCL3018NR, CCL3018PR, CCL3018NRA, CCL3018PRA, CCL3924NR, CCL3924PR, CCL3924NRA, CCL3924PRA, CHL3924NR, CHL3924PR, CCL3930NR, CCL3930PR, CCL3930NRA, and CCL3930PRA, exemplifies this commitment to quality and innovation.

At the core of these models are advanced heating technologies designed to provide efficient, effective warmth for a variety of applications. Each unit is engineered to produce reliable heating output while minimizing energy consumption, making them an ideal choice for both residential and commercial environments.

One standout feature is the incorporation of intelligent temperature controls that allow users to seamlessly adjust their heating schedule and preferences. This enhances user convenience while optimizing energy savings. Many models also feature a compact design that allows for flexible installation options, whether mounted on walls or placed in strategic locations for maximum heating efficiency.

A common characteristic across the CCL and CHL series is their robust construction and durable components, enabling them to withstand varying environmental conditions. This makes them suitable not only for indoor use but also for outdoor heating applications, providing versatility in heating solutions.

Additionally, these models are equipped with advanced safety features such as overheat protection and tip-over switches, ensuring peace of mind for users. The inclusion of energy-efficient technologies, such as ceramic heating elements in certain models, contributes to quicker heating times while maintaining safe operation.

The CCL3930PRA and CCL3924PRA models, for example, not only offer high heating capacities but also have a modern aesthetic design that complements a variety of decors. This attention to design ensures that homes can benefit from effective heating without sacrificing style.

Furthermore, the range's adaptability makes it suitable for various settings, from workshops and garages to homes. As such, it can meet diverse heating demands, whether it’s for maintaining a cozy environment during frigid winters or providing a comfortable workspace year-round.

In conclusion, the Desa Tech CCL series, including CCL3018NR, CCL3930PRA, and their counterparts, represents a confluence of innovative technology, reliable performance, and user-focused design. With a strong emphasis on efficiency and safety, these heating solutions are poised to deliver exceptional value to users while ensuring a warm and inviting atmosphere in any space.