Desa Tech CCL3930PRA, CCL3018NR installation manual Parts List

Page 29

PARTS LIST

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 33 of this manual.

KEY

 

PART NUMBER

 

 

 

NO.

CCL3018PR

CCL3018PRA

CCL3018NR

CCL3018NRA

DESCRIPTION

QTY

 

 

 

 

 

 

 

1

105958-04

111340-03

105958-04

111340-03

Front Log

1

2

105959-04

111341-03

105959-04

111341-03

Middle Log

1

3

105960-04

111342-03

105960-04

111342-03

Back Log

1

4

105961-04

111343-03

105961-04

111343-03

Left Back Crossover Log

1

5

105962-04

111344-02

105962-04

111344-02

Left Top Crossover Log

1

6

105963-04

111345-02

105963-04

111345-02

Right Bottom Crossover

 

 

 

 

 

 

Log (#6)

1

7

103778-01

103778-01

103779-01

103779-01

ODS Pilot

1

8

098249-01

098249-01

098249-01

098249-01

ODS Nut

2

9

111331-01

111331-01

104422-05

104422-05

Burner Outlet Tube

1

10

098264-02

098264-02

098264-02

098264-02

Male Connector

1

11

111124-01

111124-01

111124-01

111124-01

Burner Retainer Spring

1

12

099056-19

099056-19

099056-26

099056-26

Burner Orifice Injector

1

13

102445-01

102445-01

102445-01

102445-01

Piezo Ignitor

1

14

102980-01

102980-01

102980-01

102980-01

Burner

1

15

100609-01

100609-01

099387-13

099387-13

Pilot Tube

1

16

____

____

099918-02

099918-02

Pilot Regulator

1

17

____

____

099387-15

099387-15

Pilot Tube (Valve to regulator)

1

18

103345-02

103345-02

103345-02

103345-02

Lower Bracket

1

19

103284-02

103284-02

103284-02

103284-02

Wiring Harness

1

20

103781-01

103781-01

103781-02

103781-02

Gas Control Valve

1

21

104099-01

104099-01

104099-01

104099-01

Heat Shield

1

22

103587-02

103587-02

103587-02

103587-02

Plate, Switch

1

23

M11084-38

M11084-38

M11084-38

M11084-38

Screw, #8 x .38

4

24

M12461-26

M12461-26

M12461-26

M12461-26

Screw, Hex Slt Wsr 10-32 x .38

4

25

**

**

**

**

Painted Base Assy

1

26

103784-01

103784-01

103784-01

103784-01

Off-Pilot-On Knob

1

27

103784-02

103784-02

103784-02

103784-02

Flame Adjustment Knob

1

28

098304-01

098304-01

098304-01

098304-01

Screw

2

29

099998-01

099998-01

099998-01

099998-01

Switch

1

30

098271-10

098271-10

098271-10

098271-10

Ignitor Cable

1

 

 

 

 

 

 

 

 

 

PARTS AVAILABLE — NOT SHOWN

 

 

100563-01

100563-01

100563-01

100563-01

Warning Plate

1

 

103877-01

103877-01

103877-01

103877-01

Lighting Instructions Plate

1

 

100565-01

100565-01

100565-01

100565-01

Warning Plate Fastener

1

 

100639-01

100639-01

100639-01

100639-01

Caution Decal

1

 

101137-02

101137-02

101137-02

101137-02

Hardware Kit

1

 

GA6060

GA6060

GA6060

GA6060

Lava Rock

1

 

 

 

 

 

 

 

** Not a field replaceable part.

111161-01D

www.desatech.com

29

Image 29
Contents Yellow Flame Model Shown CCL3930NR, CCL3930PR CCL3930NRA, CCL3930PRATable of Contents Safety Information Local Codes Remote Control Accessories Product FeaturesProduct Identification UnpackingDetermining FRESH-AIR Flow for Heater Location Providing Adequate VentilationUnusually Tight Construction Confined Space and Unconfined SpaceVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallationLog Installation and Clearances Vent-Free Operation OnlyMantel Clearances If Using MantelFloor Clearances Installing Damper Clamp Accessory for VentedInstallation Items Needed Installing Heater Base AssemblyExternal Regulator With Vent Pointing Down Connecting to GAS SupplyTest Pressures In Excess Of 1/2 Psig 3.5 kPa Checking GAS ConnectionsTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Installing Remote Receiver UnitInstalling 9-Volt Battery in Receiver Installing Wireless HAND- Held Remote Control AccessoryInstalling Front Log #1 CCL3930PR/NR Shown Installing LogsInstalling Crossover Log #4 CCL3930PR/NR Shown Lighting Instructions For Your Safety Read Before LightingOperating Heater To Turn OFF GAS To Appliance Optional HAND-HELD Remote Operation Manual Lighting ProcedureON/OFF Series Model Cghrcb Thermostat Series Model CghrctbPilot Flame Pattern Inspecting BurnersBurner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceLogs Main BurnerObserved Problem Possible Cause Remedy TroubleshootingPress in control knob fully See Cleaning and Mainte Gas leak. See Warning Models CCL3018PR, CCL3018PRA, CCL3018NR, and CCL3018NRA Illustrated Parts BreakdownParts List Models Remote Receiver CHL Only Wiring Diagram Technical Service SpecificationsService Hints When Gas Pressure Is Too LowParts Under Warranty Replacement PartsParts not Under Warranty Parts CentralCleaning KIT CCK Receiver and HAND-HELD Remote Control KIT Cghrcb SeriesEquipment Shutoff Valve GA5010 Fireplace Hood111161-01D Limited Warranty Comfort Glow VENT-FREE GAS LOG Heaters Warranty InformationKeep this Warranty

CCL3018NR, CCL3018PR, CCL3018NRA, CCL3018PRA, CCL3924NR, CCL3924PR, CCL3924NRA, CCL3924PRA, CHL3924NR, CHL3924PR, CCL3930NR, CCL3930PR, CCL3930NRA, CCL3930PRA, CCL3018NR, CCL3930PRA specifications

Desa Tech has established a reputation for engineering high-performance heating solutions, and its range of products, including models such as CCL3018NR, CCL3930PRA, CCL3018NR, CCL3018PR, CCL3018NRA, CCL3018PRA, CCL3924NR, CCL3924PR, CCL3924NRA, CCL3924PRA, CHL3924NR, CHL3924PR, CCL3930NR, CCL3930PR, CCL3930NRA, and CCL3930PRA, exemplifies this commitment to quality and innovation.

At the core of these models are advanced heating technologies designed to provide efficient, effective warmth for a variety of applications. Each unit is engineered to produce reliable heating output while minimizing energy consumption, making them an ideal choice for both residential and commercial environments.

One standout feature is the incorporation of intelligent temperature controls that allow users to seamlessly adjust their heating schedule and preferences. This enhances user convenience while optimizing energy savings. Many models also feature a compact design that allows for flexible installation options, whether mounted on walls or placed in strategic locations for maximum heating efficiency.

A common characteristic across the CCL and CHL series is their robust construction and durable components, enabling them to withstand varying environmental conditions. This makes them suitable not only for indoor use but also for outdoor heating applications, providing versatility in heating solutions.

Additionally, these models are equipped with advanced safety features such as overheat protection and tip-over switches, ensuring peace of mind for users. The inclusion of energy-efficient technologies, such as ceramic heating elements in certain models, contributes to quicker heating times while maintaining safe operation.

The CCL3930PRA and CCL3924PRA models, for example, not only offer high heating capacities but also have a modern aesthetic design that complements a variety of decors. This attention to design ensures that homes can benefit from effective heating without sacrificing style.

Furthermore, the range's adaptability makes it suitable for various settings, from workshops and garages to homes. As such, it can meet diverse heating demands, whether it’s for maintaining a cozy environment during frigid winters or providing a comfortable workspace year-round.

In conclusion, the Desa Tech CCL series, including CCL3018NR, CCL3930PRA, and their counterparts, represents a confluence of innovative technology, reliable performance, and user-focused design. With a strong emphasis on efficiency and safety, these heating solutions are poised to deliver exceptional value to users while ensuring a warm and inviting atmosphere in any space.