Desa Tech CCL3930PRA, CCL3018NR installation manual To Turn OFF GAS To Appliance

Page 20

OPERATING HEATER

Continued

4.Press in and turn control knob clockwise to the OFF position (see Figure 32).

5.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information, page 19. If you don’t smell gas, go to the next step.

6.Press in and turn control knob counter-

clockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 32).

Note: You may be running this heater for the first time after hooking up to gas sup- ply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system.

7.With control knob pressed in, press and re- lease ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 21.

8.Keep control knob pressed in for 30 sec- onds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop out when re- leased, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 4 through 8.

9.Slightly push in and turn control knob

counterclockwise to the ON position.

10.Wait one minute and switch selector switch to the ON position to light burners.

11.Set flame adjustment knob to any level be- tween HI and LO.

 

Flame Adjustment

Control

 

Knob

 

Knob

 

 

 

 

IH

 

 

 

REMOTE

 

O

 

OFF

 

 

 

F

 

ON

N

F

 

O

IP

 

LO

 

TOL

Ignitor

Selector Switch

 

 

Button

in OFF Position

 

 

Figure 32 - Control Knob and Ignitor

Button Location

CAUTION: Do not try to ad- just heating levels by using the equipment shutoff valve.

WARNING: Make sure the selector switch is in the OFF position when you are away from home for long periods of time. Heater will come on automati- cally with selector switch in the ON position.

Pilot Burner

Ignitor

 

Electrode

Propane/LP Gas

Pilot Burner

Ignitor

 

Electrode

Natural Gas

Figure 33 - Pilot

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise to the OFF position.

2a. Set selector switch in the OFF position.

2b. If Using Optional Hand-Held remote: Set se- lector switch in the OFF position to keep from draining battery.

Shutting Off Burners Only (pilot stays lit)

You may shut off the burners and keep the pi- lot lit by doing one of the following:

1.Turn control knob clockwise to the PILOT position.

2.Use remote control manual OFF button.

3.Set selector switch in the OFF position.

20

www.desatech.com

111161-01D

Image 20
Contents CCL3930NR, CCL3930PR CCL3930NRA, CCL3930PRA Yellow Flame Model ShownTable of Contents Safety Information Local Codes Product Features Remote Control AccessoriesProduct Identification UnpackingProviding Adequate Ventilation Determining FRESH-AIR Flow for Heater LocationUnusually Tight Construction Confined Space and Unconfined SpaceVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installation Check GAS TypeInstallation and Clearances Vent-Free Operation Only LogIf Using Mantel Mantel ClearancesInstalling Damper Clamp Accessory for Vented Floor ClearancesInstalling Heater Base Assembly Installation Items NeededConnecting to GAS Supply External Regulator With Vent Pointing DownChecking GAS Connections Test Pressures In Excess Of 1/2 Psig 3.5 kPaInstalling Remote Receiver Unit Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaInstalling Wireless HAND- Held Remote Control Accessory Installing 9-Volt Battery in ReceiverInstalling Logs Installing Front Log #1 CCL3930PR/NR ShownInstalling Crossover Log #4 CCL3930PR/NR Shown Lighting Instructions For Your Safety Read Before LightingOperating Heater To Turn OFF GAS To Appliance Manual Lighting Procedure Optional HAND-HELD Remote OperationON/OFF Series Model Cghrcb Thermostat Series Model CghrctbInspecting Burners Pilot Flame PatternCleaning Maintenance Burner Injector Holder and Pilot AIR Inlet HoleLogs Main BurnerTroubleshooting Observed Problem Possible Cause RemedyPress in control knob fully See Cleaning and Mainte Gas leak. See Warning Illustrated Parts Breakdown Models CCL3018PR, CCL3018PRA, CCL3018NR, and CCL3018NRAParts List Models Remote Receiver CHL Only Specifications Wiring Diagram Technical ServiceService Hints When Gas Pressure Is Too LowReplacement Parts Parts Under WarrantyParts not Under Warranty Parts CentralReceiver and HAND-HELD Remote Control KIT Cghrcb Series Cleaning KIT CCKEquipment Shutoff Valve GA5010 Fireplace Hood111161-01D Limited Warranty Comfort Glow VENT-FREE GAS LOG Heaters Warranty InformationKeep this Warranty

CCL3018NR, CCL3018PR, CCL3018NRA, CCL3018PRA, CCL3924NR, CCL3924PR, CCL3924NRA, CCL3924PRA, CHL3924NR, CHL3924PR, CCL3930NR, CCL3930PR, CCL3930NRA, CCL3930PRA, CCL3018NR, CCL3930PRA specifications

Desa Tech has established a reputation for engineering high-performance heating solutions, and its range of products, including models such as CCL3018NR, CCL3930PRA, CCL3018NR, CCL3018PR, CCL3018NRA, CCL3018PRA, CCL3924NR, CCL3924PR, CCL3924NRA, CCL3924PRA, CHL3924NR, CHL3924PR, CCL3930NR, CCL3930PR, CCL3930NRA, and CCL3930PRA, exemplifies this commitment to quality and innovation.

At the core of these models are advanced heating technologies designed to provide efficient, effective warmth for a variety of applications. Each unit is engineered to produce reliable heating output while minimizing energy consumption, making them an ideal choice for both residential and commercial environments.

One standout feature is the incorporation of intelligent temperature controls that allow users to seamlessly adjust their heating schedule and preferences. This enhances user convenience while optimizing energy savings. Many models also feature a compact design that allows for flexible installation options, whether mounted on walls or placed in strategic locations for maximum heating efficiency.

A common characteristic across the CCL and CHL series is their robust construction and durable components, enabling them to withstand varying environmental conditions. This makes them suitable not only for indoor use but also for outdoor heating applications, providing versatility in heating solutions.

Additionally, these models are equipped with advanced safety features such as overheat protection and tip-over switches, ensuring peace of mind for users. The inclusion of energy-efficient technologies, such as ceramic heating elements in certain models, contributes to quicker heating times while maintaining safe operation.

The CCL3930PRA and CCL3924PRA models, for example, not only offer high heating capacities but also have a modern aesthetic design that complements a variety of decors. This attention to design ensures that homes can benefit from effective heating without sacrificing style.

Furthermore, the range's adaptability makes it suitable for various settings, from workshops and garages to homes. As such, it can meet diverse heating demands, whether it’s for maintaining a cozy environment during frigid winters or providing a comfortable workspace year-round.

In conclusion, the Desa Tech CCL series, including CCL3018NR, CCL3930PRA, and their counterparts, represents a confluence of innovative technology, reliable performance, and user-focused design. With a strong emphasis on efficiency and safety, these heating solutions are poised to deliver exceptional value to users while ensuring a warm and inviting atmosphere in any space.