Desa Tech CCL3930PRA, CCL3018NR Installing Heater Base Assembly, Installation Items Needed

Page 12

INSTALLATION

Continued

Damper

Clamp

Damper

Damper

Clamp

DamperDamper

Masonry Fireplace

Manufactured Fireplace

Figure 10 - Attaching Damper Clamp

INSTALLING HEATER BASE ASSEMBLY

CAUTION: Do not remove the data plates attached to the heater base assembly. The data plates contain important war- ranty and safety information.

WARNING: You must secure this heater to fireplace floor. If not, heater will move when you adjust controls. Moving heater may cause a gas leak.

WARNING: If installing in a sunken fireplace, special care is needed. You must raise the fire- place floor to allow access to heater control panel. This will in- sure adequate air flow and guard against sooting and controls be- ingdamaged.Raisefireplacefloor with noncombustible material. Make sure material is secure.

CAUTION: Do not pick up heater base assembly by burners. This could damage heater. Only handle base assembly by grates.

IMPORTANT:Make sure the heater burners are level. If heater is not level, heater will not work properly.

Installation Items Needed

hardware package (provided with heater)

approved flexible gas hose (not provided) (if allowed by local codes)

sealant resistant to propane/LP gas, not provided

electric drill with 3/16" masonry drill bit Note: Install optional remote receiver and hand- held remote kit (see Accessories, page 34) before installing gas log heater. See installation instruc- tions included with the kit.

1.Apply pipe joint sealant lightly to male threads of the fitting to be threaded into gas regulator. Connect approved flexible gas hose to gas regulator of heater (see Figure 11).

2.Locate masonry screws in hardware package.

3.Position heater base assembly in fireplace.

4.Place logs in their proper positions on heater base.

5.Center heater base and logs front-to-back and side-to-side in fireplace.

6.Carefully remove logs without moving heater base.

7.Mark screw locations through holes in mount- ing flanges (see Figure 12). If installing in a brick-bottom fireplace, mark screw locations in mortar joint of bricks.

8.Remove heater base from fireplace.

9.Drill holes at marked locations using 3/16" masonry drill bit.

10.Attach base assembly to fireplace floor using two masonry screws (in hardware package) (see Figure 12).

11.Connect to gas supply. See Connecting To Gas Supply, page 13.

Flexible Gas Hose

(if allowed by local codes) Fitting

Figure 11 - Attaching Flexible Gas Hose

to Heater

Masonry Screw

Mounting

Flanges

Figure 12 - Attaching Base Assembly to

Fireplace Floor

12

www.desatech.com

111161-01D

Image 12
Contents CCL3930NR, CCL3930PR CCL3930NRA, CCL3930PRA Yellow Flame Model ShownTable of Contents Safety Information Local Codes Product Features Remote Control AccessoriesProduct Identification UnpackingProviding Adequate Ventilation Determining FRESH-AIR Flow for Heater LocationUnusually Tight Construction Confined Space and Unconfined SpaceVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Check GAS TypeInstallation and Clearances Vent-Free Operation Only LogIf Using Mantel Mantel ClearancesInstalling Damper Clamp Accessory for Vented Floor ClearancesInstalling Heater Base Assembly Installation Items NeededConnecting to GAS Supply External Regulator With Vent Pointing DownChecking GAS Connections Test Pressures In Excess Of 1/2 Psig 3.5 kPaInstalling Remote Receiver Unit Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaInstalling Wireless HAND- Held Remote Control Accessory Installing 9-Volt Battery in ReceiverInstalling Logs Installing Front Log #1 CCL3930PR/NR ShownInstalling Crossover Log #4 CCL3930PR/NR Shown For Your Safety Read Before Lighting Operating HeaterLighting Instructions To Turn OFF GAS To Appliance Manual Lighting Procedure Optional HAND-HELD Remote OperationON/OFF Series Model Cghrcb Thermostat Series Model CghrctbInspecting Burners Pilot Flame PatternCleaning Maintenance Burner Injector Holder and Pilot AIR Inlet HoleLogs Main BurnerTroubleshooting Observed Problem Possible Cause RemedyPress in control knob fully See Cleaning and Mainte Gas leak. See Warning Illustrated Parts Breakdown Models CCL3018PR, CCL3018PRA, CCL3018NR, and CCL3018NRAParts List Models Remote Receiver CHL Only Specifications Wiring Diagram Technical ServiceService Hints When Gas Pressure Is Too LowReplacement Parts Parts Under WarrantyParts not Under Warranty Parts CentralReceiver and HAND-HELD Remote Control KIT Cghrcb Series Cleaning KIT CCKEquipment Shutoff Valve GA5010 Fireplace Hood111161-01D Warranty Information Keep this WarrantyLimited Warranty Comfort Glow VENT-FREE GAS LOG Heaters

CCL3018NR, CCL3018PR, CCL3018NRA, CCL3018PRA, CCL3924NR, CCL3924PR, CCL3924NRA, CCL3924PRA, CHL3924NR, CHL3924PR, CCL3930NR, CCL3930PR, CCL3930NRA, CCL3930PRA, CCL3018NR, CCL3930PRA specifications

Desa Tech has established a reputation for engineering high-performance heating solutions, and its range of products, including models such as CCL3018NR, CCL3930PRA, CCL3018NR, CCL3018PR, CCL3018NRA, CCL3018PRA, CCL3924NR, CCL3924PR, CCL3924NRA, CCL3924PRA, CHL3924NR, CHL3924PR, CCL3930NR, CCL3930PR, CCL3930NRA, and CCL3930PRA, exemplifies this commitment to quality and innovation.

At the core of these models are advanced heating technologies designed to provide efficient, effective warmth for a variety of applications. Each unit is engineered to produce reliable heating output while minimizing energy consumption, making them an ideal choice for both residential and commercial environments.

One standout feature is the incorporation of intelligent temperature controls that allow users to seamlessly adjust their heating schedule and preferences. This enhances user convenience while optimizing energy savings. Many models also feature a compact design that allows for flexible installation options, whether mounted on walls or placed in strategic locations for maximum heating efficiency.

A common characteristic across the CCL and CHL series is their robust construction and durable components, enabling them to withstand varying environmental conditions. This makes them suitable not only for indoor use but also for outdoor heating applications, providing versatility in heating solutions.

Additionally, these models are equipped with advanced safety features such as overheat protection and tip-over switches, ensuring peace of mind for users. The inclusion of energy-efficient technologies, such as ceramic heating elements in certain models, contributes to quicker heating times while maintaining safe operation.

The CCL3930PRA and CCL3924PRA models, for example, not only offer high heating capacities but also have a modern aesthetic design that complements a variety of decors. This attention to design ensures that homes can benefit from effective heating without sacrificing style.

Furthermore, the range's adaptability makes it suitable for various settings, from workshops and garages to homes. As such, it can meet diverse heating demands, whether it’s for maintaining a cozy environment during frigid winters or providing a comfortable workspace year-round.

In conclusion, the Desa Tech CCL series, including CCL3018NR, CCL3930PRA, and their counterparts, represents a confluence of innovative technology, reliable performance, and user-focused design. With a strong emphasis on efficiency and safety, these heating solutions are poised to deliver exceptional value to users while ensuring a warm and inviting atmosphere in any space.