Desa Tech CCL3930PRA, CCL3018NR Installing Damper Clamp Accessory for Vented, Floor Clearances

Page 11

INSTALLATION

Continued

NOTICE: If your installation does not meet the minimum clear- ances shown, you must do one of the following:

operate the logs only with the flue damper open

raise the mantel to an accept- able height

remove the mantel.

Hearth

Combustible Material

5"

Min.

Figure 9 - Minimum Fireplace Clearances

Above Combustible Flooring

INSTALLING DAMPER CLAMP ACCESSORY FOR VENTED

12"

10"

8"

6"

2 1/2"

Minimum

Noncombustible

Material

8"

Min.

Hood (GA6050, GA6052)

Mantel Shelf

Underside

of Mantel

Shelf

All minimum distances are in inches

Log Set

12" 15" 18" 20" 18",All 24", 30" Models Models

Top of Fireplace

Opening

Distances to Underside of Mantel

OPERATION

Note: When used as a vented heater, appliance must be installed only in a solid-fuel burning fire- place with a working flue and constructed of non- combustible material.

If you choose to use your heater as a manually- controlled model (no remote control installed), you may use this heater as a vented product. There are three reasons for operating your heater in the vented mode.

1.The fireplace does not meet the clearance to combustibles requirements for vent-free op- eration.

2.State or local codes do not permit vent-free operation.

3.You prefer vented operation.

Figure 7 - Minimum Mantel Clearances

When Using Hood

FLOOR CLEARANCES

A.If installing appliance on the floor level, you must maintain the minimum distance of 14" to combustibles (see Figure 8).

B.If combustible materials are less than 14" to the fireplace, you must install appliance at least 5" above the combustible flooring (see Figure 9).

If reasons number 1 or 2 above apply to you, you must permanently open chimney flue damper. You must install the damper clamp accessory (to order, see Accessories, page 34). This will insure vented operation (see Figure 10, page 12). The damper clamp will keep damper open. Installation instruc- tions are included with clamp accessory.

See chart below for minimum permanent flue opening you must provide. Attach damper clamp so the minimum permanent flue opening will be maintained at all times.

Chimney

Minimum Permanent

Height (ft.)

Flue Opening (sq. in.)

 

 

6' to 15'

39 sq. inches

15' to 30'

29 sq. inches

14"

Combustible Material

Area of Various Standard Round Flues

Min.

Noncombustible Material

Figure 8 - Minimum Fireplace Clearances

If Installed at Floor Level

Diameter (inches)

Area (sq. inches)

5

20

6

29

7

39

8

51

111161-01D

www.desatech.com

11

Image 11
Contents Yellow Flame Model Shown CCL3930NR, CCL3930PR CCL3930NRA, CCL3930PRATable of Contents Safety Information Local Codes Unpacking Product FeaturesRemote Control Accessories Product IdentificationConfined Space and Unconfined Space Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Unusually Tight ConstructionVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallationLog Installation and Clearances Vent-Free Operation OnlyMantel Clearances If Using MantelFloor Clearances Installing Damper Clamp Accessory for VentedInstallation Items Needed Installing Heater Base AssemblyExternal Regulator With Vent Pointing Down Connecting to GAS SupplyTest Pressures In Excess Of 1/2 Psig 3.5 kPa Checking GAS ConnectionsTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Installing Remote Receiver UnitInstalling 9-Volt Battery in Receiver Installing Wireless HAND- Held Remote Control AccessoryInstalling Front Log #1 CCL3930PR/NR Shown Installing LogsInstalling Crossover Log #4 CCL3930PR/NR Shown Lighting Instructions For Your Safety Read Before LightingOperating Heater To Turn OFF GAS To Appliance Thermostat Series Model Cghrctb Manual Lighting ProcedureOptional HAND-HELD Remote Operation ON/OFF Series Model CghrcbPilot Flame Pattern Inspecting BurnersMain Burner Cleaning MaintenanceBurner Injector Holder and Pilot AIR Inlet Hole LogsObserved Problem Possible Cause Remedy TroubleshootingPress in control knob fully See Cleaning and Mainte Gas leak. See Warning Models CCL3018PR, CCL3018PRA, CCL3018NR, and CCL3018NRA Illustrated Parts BreakdownParts List Models Remote Receiver CHL Only When Gas Pressure Is Too Low SpecificationsWiring Diagram Technical Service Service HintsParts Central Replacement PartsParts Under Warranty Parts not Under WarrantyFireplace Hood Receiver and HAND-HELD Remote Control KIT Cghrcb SeriesCleaning KIT CCK Equipment Shutoff Valve GA5010111161-01D Limited Warranty Comfort Glow VENT-FREE GAS LOG Heaters Warranty InformationKeep this Warranty

CCL3018NR, CCL3018PR, CCL3018NRA, CCL3018PRA, CCL3924NR, CCL3924PR, CCL3924NRA, CCL3924PRA, CHL3924NR, CHL3924PR, CCL3930NR, CCL3930PR, CCL3930NRA, CCL3930PRA, CCL3018NR, CCL3930PRA specifications

Desa Tech has established a reputation for engineering high-performance heating solutions, and its range of products, including models such as CCL3018NR, CCL3930PRA, CCL3018NR, CCL3018PR, CCL3018NRA, CCL3018PRA, CCL3924NR, CCL3924PR, CCL3924NRA, CCL3924PRA, CHL3924NR, CHL3924PR, CCL3930NR, CCL3930PR, CCL3930NRA, and CCL3930PRA, exemplifies this commitment to quality and innovation.

At the core of these models are advanced heating technologies designed to provide efficient, effective warmth for a variety of applications. Each unit is engineered to produce reliable heating output while minimizing energy consumption, making them an ideal choice for both residential and commercial environments.

One standout feature is the incorporation of intelligent temperature controls that allow users to seamlessly adjust their heating schedule and preferences. This enhances user convenience while optimizing energy savings. Many models also feature a compact design that allows for flexible installation options, whether mounted on walls or placed in strategic locations for maximum heating efficiency.

A common characteristic across the CCL and CHL series is their robust construction and durable components, enabling them to withstand varying environmental conditions. This makes them suitable not only for indoor use but also for outdoor heating applications, providing versatility in heating solutions.

Additionally, these models are equipped with advanced safety features such as overheat protection and tip-over switches, ensuring peace of mind for users. The inclusion of energy-efficient technologies, such as ceramic heating elements in certain models, contributes to quicker heating times while maintaining safe operation.

The CCL3930PRA and CCL3924PRA models, for example, not only offer high heating capacities but also have a modern aesthetic design that complements a variety of decors. This attention to design ensures that homes can benefit from effective heating without sacrificing style.

Furthermore, the range's adaptability makes it suitable for various settings, from workshops and garages to homes. As such, it can meet diverse heating demands, whether it’s for maintaining a cozy environment during frigid winters or providing a comfortable workspace year-round.

In conclusion, the Desa Tech CCL series, including CCL3018NR, CCL3930PRA, and their counterparts, represents a confluence of innovative technology, reliable performance, and user-focused design. With a strong emphasis on efficiency and safety, these heating solutions are poised to deliver exceptional value to users while ensuring a warm and inviting atmosphere in any space.