Desa Tech CCL3930PRA, CCL3018NR installation manual Installation, Check GAS Type

Page 8

INSTALLATION

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your pri- mary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

NOTICE: State or local codes may only allow operation of this appliance in a vented configura- tion. Check your state or local codes.

WARNING: A qualified ser- vice person must install heater. Follow all local codes.

WARNING: Make sure the selector switch is in the OFF position before installing heater.

WARNING: Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creo- sote, ashes, and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. A dirty chimney flue may create and distribute soot within the house. Inspect chimney flue for damage. If damaged, repair flue before operating heater.

WARNING: Seal any fresh air vents or ash clean-out doors located on floor or wall of fire- place. If not, drafting may cause pilot outage or sooting. Use a heat-resistant sealant. Do not seal chimney flue damper.

WARNING: Never install the heater

in a bedroom or bathroom un- less installed as a vented ap- pliance, see page 11.

in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 42 inches from the front, top, or sides of the heater

in high traffic areas

in windy or drafty areas

CAUTION: This heater cre- ates warm air currents. These currents move heat to wall sur- faces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as, but not limited to, tobacco smoke, aromatic candles, cleaning flu- ids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors.

IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, page 5.

CHECK GAS TYPE

Use the correct gas type (natural or propane/LP) for your unit. If your gas supply is not correct, do not install heater. Call dealer where you bought heater for proper type heater.

8

www.desatech.com

111161-01D

Image 8
Contents CCL3930NR, CCL3930PR CCL3930NRA, CCL3930PRA Yellow Flame Model ShownTable of Contents Safety Information Local Codes Product Features Remote Control AccessoriesProduct Identification UnpackingProviding Adequate Ventilation Determining FRESH-AIR Flow for Heater LocationUnusually Tight Construction Confined Space and Unconfined SpaceVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installation Check GAS TypeInstallation and Clearances Vent-Free Operation Only LogIf Using Mantel Mantel ClearancesInstalling Damper Clamp Accessory for Vented Floor ClearancesInstalling Heater Base Assembly Installation Items NeededConnecting to GAS Supply External Regulator With Vent Pointing DownChecking GAS Connections Test Pressures In Excess Of 1/2 Psig 3.5 kPaInstalling Remote Receiver Unit Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaInstalling Wireless HAND- Held Remote Control Accessory Installing 9-Volt Battery in ReceiverInstalling Logs Installing Front Log #1 CCL3930PR/NR ShownInstalling Crossover Log #4 CCL3930PR/NR Shown Lighting Instructions For Your Safety Read Before LightingOperating Heater To Turn OFF GAS To Appliance Manual Lighting Procedure Optional HAND-HELD Remote OperationON/OFF Series Model Cghrcb Thermostat Series Model CghrctbInspecting Burners Pilot Flame PatternCleaning Maintenance Burner Injector Holder and Pilot AIR Inlet HoleLogs Main BurnerTroubleshooting Observed Problem Possible Cause RemedyPress in control knob fully See Cleaning and Mainte Gas leak. See Warning Illustrated Parts Breakdown Models CCL3018PR, CCL3018PRA, CCL3018NR, and CCL3018NRAParts List Models Remote Receiver CHL Only Specifications Wiring Diagram Technical ServiceService Hints When Gas Pressure Is Too LowReplacement Parts Parts Under WarrantyParts not Under Warranty Parts CentralReceiver and HAND-HELD Remote Control KIT Cghrcb Series Cleaning KIT CCKEquipment Shutoff Valve GA5010 Fireplace Hood111161-01D Limited Warranty Comfort Glow VENT-FREE GAS LOG Heaters Warranty InformationKeep this Warranty

CCL3018NR, CCL3018PR, CCL3018NRA, CCL3018PRA, CCL3924NR, CCL3924PR, CCL3924NRA, CCL3924PRA, CHL3924NR, CHL3924PR, CCL3930NR, CCL3930PR, CCL3930NRA, CCL3930PRA, CCL3018NR, CCL3930PRA specifications

Desa Tech has established a reputation for engineering high-performance heating solutions, and its range of products, including models such as CCL3018NR, CCL3930PRA, CCL3018NR, CCL3018PR, CCL3018NRA, CCL3018PRA, CCL3924NR, CCL3924PR, CCL3924NRA, CCL3924PRA, CHL3924NR, CHL3924PR, CCL3930NR, CCL3930PR, CCL3930NRA, and CCL3930PRA, exemplifies this commitment to quality and innovation.

At the core of these models are advanced heating technologies designed to provide efficient, effective warmth for a variety of applications. Each unit is engineered to produce reliable heating output while minimizing energy consumption, making them an ideal choice for both residential and commercial environments.

One standout feature is the incorporation of intelligent temperature controls that allow users to seamlessly adjust their heating schedule and preferences. This enhances user convenience while optimizing energy savings. Many models also feature a compact design that allows for flexible installation options, whether mounted on walls or placed in strategic locations for maximum heating efficiency.

A common characteristic across the CCL and CHL series is their robust construction and durable components, enabling them to withstand varying environmental conditions. This makes them suitable not only for indoor use but also for outdoor heating applications, providing versatility in heating solutions.

Additionally, these models are equipped with advanced safety features such as overheat protection and tip-over switches, ensuring peace of mind for users. The inclusion of energy-efficient technologies, such as ceramic heating elements in certain models, contributes to quicker heating times while maintaining safe operation.

The CCL3930PRA and CCL3924PRA models, for example, not only offer high heating capacities but also have a modern aesthetic design that complements a variety of decors. This attention to design ensures that homes can benefit from effective heating without sacrificing style.

Furthermore, the range's adaptability makes it suitable for various settings, from workshops and garages to homes. As such, it can meet diverse heating demands, whether it’s for maintaining a cozy environment during frigid winters or providing a comfortable workspace year-round.

In conclusion, the Desa Tech CCL series, including CCL3018NR, CCL3930PRA, and their counterparts, represents a confluence of innovative technology, reliable performance, and user-focused design. With a strong emphasis on efficiency and safety, these heating solutions are poised to deliver exceptional value to users while ensuring a warm and inviting atmosphere in any space.