Desa CDVBPC, CDVBNC Safety Information Product Identification, Cleaning stove or burner system

Page 3

SAFETY INFORMATION PRODUCT IDENTIFICATION

3

SAFETY INFORMATION

Continued

PRODUCT IDENTIFICATION

5.

This stove reaches high temperatures. Keep children and adults

 

away from hot surfaces to avoid burns or clothing ignition.

 

Stove will remain hot for a time after shutdown. Allow sur-

 

faces to cool before touching.

6.

Carefully supervise young children when they are in the room

 

with stove.

7.

Do not modify the burner or stove under any circumstances.

 

Any parts removed for servicing must be replaced prior to op-

 

erating burner system.

8.

Turn burner system off and let cool before servicing, install-

 

ing, or repairing. Only a qualified service person should in-

 

stall, service, or repair the stove or burner system. Have burner

 

system inspected annually by a qualified service person.

9.

You must keep control compartments, burners, and circulat-

 

ing air passages clean. More frequent cleaning may be needed

 

due to excessive lint and dust from carpeting, bedding mate-

 

rial, pet hair, etc. Turn off the gas valve and pilot light before

 

cleaning stove or burner system.

Cast Iron Stove Body

Log Set

 

ON

LO H

 

 

OFF

I

OFF

 

AUTO

 

 

 

 

ON

ON/OFF

Piezo Ignitor

 

Control

Switch

 

 

Valve

 

 

 

 

 

10.

Have venting system inspected annually by a qualified service

 

person. If needed, have venting system cleaned or repaired.

 

See Cleaning and Maintenance, page 28.

11. Keep the area around your stove clear of combustible materi-

 

als, gasoline, and other flammable vapor and liquids. Do not

 

run burner system where these are used or stored. Do not place

 

items such as clothing or decorations on or around stove.

12. Do not use this stove to cook food or burn paper or other objects.

13.

Never place anything on top of stove.

14.

Do not use any solid fuels (wood, coal, paper, cardboard, etc.)

 

in this stove. Use only the gas type indicated on burner system

 

nameplate.

15.

This appliance, when installed, must be electrically grounded

 

in accordance with local codes or, in the absence of local codes,

 

with the National Electrical Code, ANSI/NFPA 70, or the Ca-

 

nadian Electrical Code, CSA C22.1.

16.

Do not obstruct the flow of combustion and ventilation air in

 

any way. Provide adequate clearances around air openings into

 

the combustion chamber along with adequate accessibility

 

clearance for servicing and proper operation.

17.

Do not install stove directly on carpeting, vinyl tile, or any com-

 

bustible material other than wood. The stove must set on a metal

 

or wood panel extending the full width and depth of the stove.

18.

Do not use stove or burner system if any part has been ex-

 

posed to or under water. Immediately call a qualified service

 

person to arrange for replacement of the unit.

19.

Do not operate burner system if any log is broken.

20.

Do not use a blower insert, heat exchanger insert, or other ac-

 

cessory not approved for use with this stove.

21. Do not operate burner system with glass door removed, cracked, or broken.

Cast Iron

 

Stove Body

Burner

Vent

Opening

Rear

Cover

Pilot

 

Assy

 

 

Glass

Blower with

Door

Assy

Adjustment

 

(Optional

 

Installation)

 

Glowing

Grate

Lava Rock

Embers

Assembly

 

Figure 1 - Comfort Glow Direct-Vent Burner System Shown Installed in Approved Comfort Glow Cast Iron Stove Body Models CISGA Series and CISCA Series Only

For morevisit www..com

105501-01F

Image 3
Contents OWNER’S Operation and Installation Manual For Your SafetyFor Your Safety What to do if YOU Smell GAS Safety Information Table of ContentsCleaning stove or burner system Safety Information Product IdentificationGlossary of Terms Product FeaturesPRE-INSTALLATION Preparation Local CodesClearance for Corner Installation Stove Body Assembly Cast Iron Stove and DIRECT-VENT Burner System AssemblyCatch Bolt and Door Claw Orientation Installing DIRECT-VENT Burner System Into Stove BodyInstalling GA3750/CDA3620T Blowers Installing Optional Blower AccessoryInstalling Rear Cover General VentingLocation of Vent Termination General Venting Venting Installation Installation PrecautionsInstallation Planning Installing Vent System in a Chase Installation for Horizontal TerminationInstalling Horizontal Vent Cap Noncombustible Exterior Horizontal Termination Configuration for Rigid Venting Horizontal Termination ConfigurationsFlat Ceiling Installation Installation for Vertical TerminationVertical Termination Configurations Cathedral Ceiling InstallationParts Lists for Venting Kits and Components High Altitude InstallationCheck GAS Type Stove and DIRECT-VENT Burner System InstallationInstalling GAS Piping to STOVE/ Burner System Location Installation Items NeededConnecting STOVE/BURNER System to GAS Supply Pressure Testing Gas Supply Piping SystemChecking GAS Connections Turn off burner system see To Turn Off Gas to Appliance, Pressure Testing Burner System Gas ConnectionsInstalling Remote Receiver Installing 9-Volt Battery in Hand-Held Remote Control UnitREMOVING/REPLACING Glass Door Removing Front Panel from Stove Installing LOGS, Lava Rock and Glowing EmbersFor Your Safety Read Before Lighting Operating Stove with Burner SystemLighting Instructions Shutting Off Burners Only pilot stays lit Manual Lighting ProcedureTo Turn OFF GAS To Appliance Optional Remote OperationOperating Optional Blower Accessory Cghrc Series OperationCghrcta Series Operation Burner Flame Pattern Pilot AssemblyInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatLogs Cleaning MaintenanceGlass Door Pilot and BurnersObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement Parts Under Warranty Wiring DiagramReplacement Parts SpecificationsCdvbnc Cdvbpc Illustrated Parts BreakdownParts List Parts ListStove Chassis Cisc Cisg KEY Part Description QTY Cisc CisgTechnical Service Service HintsAccessories Owners Registration Form Postage Required 105501-01F Warranty Information