Desa CDVBPC, CDVBNC General Venting, Installing Rear Cover, Location of Vent Termination

Page 9

CAST IRON STOVE AND DIRECT-VENT BURNER SYSTEM ASSEMBLY

Installing Optional Blower Accessory (Cont.)

Installing Rear Cover

GENERAL VENTING

Location Of Vent Termination

9

CAST IRON STOVE AND DIRECT-VENT BURNER SYSTEM ASSEMBLY

Continued

WARNING: Failure to position the parts in accor- dance with supplied diagrams or failure to use only parts specifically approved with this stove and burner system may result in damage or personal injury.

8.Connect or reconnect gas supply to stove and burner system per Connecting Stove/Burner System to Gas Supply on page 20 of this manual.

WARNING: A qualified service person must con- nect burner system to gas supply. Follow all local codes.

INSTALLING REAR COVER

1.Lift rear panel over vent pipe connection on burner system. Rear cover will rest on the bottom ledge of the stove body.

2.Using screws provided, attach rear cover to back of stove body. See Figure 17.

IMPORTANT: This rear cover must be securely in place be- fore venting pipes are installed.

GENERAL VENTING

These models are approved for use with Simpson Dura-Vent 6 5/8" direct-vent pipe components and terminations as well as both flex and rigid Comfort Glow vent components.

Your stove with burner system is approved to be vented either through the side wall, or vertically using the following guidelines:

Only use Comfort Glow or Simpson Dura-Vent GS venting com- ponents or kits specifically approved for this stove and burner system.

Minimum clearance between vent pipes and combustible mate- rials is 1" (25 mm), except where stated otherwise.

Do not recess venting terminals into a wall or siding.

Install horizontal venting with a 1/4" rise for every 12" of run toward the termination.

You may paint the vent terminal with 450ºF (232ºC) heat-resis- tant paint to coordinate with the exterior finish.

There must not be any obstruction such as bushes, garden sheds, fences, decks, or utility buildings within 24" from the front of the termination cap.

Do not locate termination cap where excessive snow or ice build up may occur. Be sure to clear vent termination area after snow falls to prevent accidental blockage of venting system. When using snow blowers, do not direct snow towards vent termina- tion area.

You must maintain minimum wall and ceiling clearances shown in Figures 3 and 4, page 5.

Rear

Cover

Figure 17 - Installing Rear Cover

LOCATION OF VENT TERMINATION

Screw

When locating vent termination, it is important to observe the minimum clearances shown in Figure 18, page 10.

*Check with local codes or with the current CAN/CGA B149[.1 or

.2] Installation Codes for Canada or the USA Installations follow the current National Fuel Gas Code, ANSI Z223.1/NFPA 54.

Burner System

Installed In Cast

Iron Stove Body

For morevisit www..com

105501-01F

Image 9
Contents OWNER’S Operation and Installation Manual For Your SafetyFor Your Safety What to do if YOU Smell GAS Safety Information Table of ContentsCleaning stove or burner system Safety Information Product IdentificationPRE-INSTALLATION Preparation Product FeaturesLocal Codes Glossary of TermsClearance for Corner Installation Stove Body Assembly Cast Iron Stove and DIRECT-VENT Burner System AssemblyCatch Bolt and Door Claw Orientation Installing DIRECT-VENT Burner System Into Stove BodyInstalling GA3750/CDA3620T Blowers Installing Optional Blower AccessoryInstalling Rear Cover General VentingLocation of Vent Termination General Venting Venting Installation Installation PrecautionsInstallation Planning Installing Vent System in a Chase Installation for Horizontal TerminationInstalling Horizontal Vent Cap Noncombustible Exterior Horizontal Termination Configuration for Rigid Venting Horizontal Termination ConfigurationsFlat Ceiling Installation Installation for Vertical TerminationVertical Termination Configurations Cathedral Ceiling InstallationParts Lists for Venting Kits and Components High Altitude InstallationInstalling GAS Piping to STOVE/ Burner System Location Stove and DIRECT-VENT Burner System InstallationInstallation Items Needed Check GAS TypeConnecting STOVE/BURNER System to GAS Supply Pressure Testing Gas Supply Piping SystemChecking GAS Connections Turn off burner system see To Turn Off Gas to Appliance, Pressure Testing Burner System Gas ConnectionsInstalling Remote Receiver Installing 9-Volt Battery in Hand-Held Remote Control UnitREMOVING/REPLACING Glass Door Removing Front Panel from Stove Installing LOGS, Lava Rock and Glowing EmbersFor Your Safety Read Before Lighting Operating Stove with Burner SystemLighting Instructions To Turn OFF GAS To Appliance Manual Lighting ProcedureOptional Remote Operation Shutting Off Burners Only pilot stays litOperating Optional Blower Accessory Cghrc Series OperationCghrcta Series Operation Inspecting Burners Pilot AssemblyOperating Optional GWMT1 Wall Mounted Thermostat Burner Flame PatternGlass Door Cleaning MaintenancePilot and Burners LogsObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement Replacement Parts Wiring DiagramSpecifications Parts Under WarrantyCdvbnc Cdvbpc Illustrated Parts BreakdownParts List Parts ListStove Chassis Cisc Cisg KEY Part Description QTY Cisc CisgTechnical Service Service HintsAccessories Owners Registration Form Postage Required 105501-01F Warranty Information