Desa CCL3924NR, CCL3930NR installation manual Remote Ready, What to do if YOU Smell GAS

Page 1

PREMIUM AGED SPLIT OAK AND

YELLOW FLAME UNVENTED (VENT-FREE)

NATURAL GAS LOG HEATERS

Also Design-Certified As Vented Decorative Appliances When

Not Used With Hand-Held Thermostat Remote

OWNER’S OPERATION AND INSTALLATION MANUAL

CGD3924NRA

CCL3924NR

CCL3930NR

24" and 30"

Remote Ready

HI

 

O

 

NO

FF

LO

OT

 

(Yellow Flame Model Shown)

WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas sup- plier, call the fire department.

Installation and service must be per- formed by a qualified installer, service agency, or the gas supplier.

WARNING: Improper installation, ad- justment, alteration, service, or mainte- nance can cause injury or property dam- age. Refer to this manual for correct installation and operational procedures. For assistance or additional informa- tion consult a qualified installer, ser- vice agency, or the gas supplier.

WARNING: This appliance is for instal- lation only in a solid-fuel burning ma- sonry or UL127 factory-built fireplace, or in an approved ventless firebox. It is design-certified for these installations in accordance with ANS Z21.11.2.

Exception: Do not install this appli- ance in a factory-built fireplace that includes instructions stating it has not been tested or should not be used with unvented gas logs.

WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to Air for Combustion and Ventilation section on page 4 of this manual.

This appliance may be installed in an aftermarket,* manufactured (mobile) home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

Save this manual for future reference.

Image 1
Contents What to do if YOU Smell GAS Remote ReadyUnvented Natural GAS LOG Heater Safety Information Product Features Safety InformationLocal Codes UnpackingAIR for Combustion and Ventilation Unvented Natural GAS LOG Heater Remote Control AccessoriesProviding Adequate Ventilation Unusually Tight ConstructionDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Check GAS Type InstallationLOG Sizing Requirements Minimum Fireplace Clearance to Combustible MaterialsMinimum Noncombustible Material Clearances Unvented Natural GAS LOG Heater InstallationMantel Clearances Determining Minimum Mantel Clearances When Using a HoodFloor Clearances Determining Minimum Mantel ClearancesInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Attaching Flexible Gas Hose to Heater Connecting to GAS SupplyPressure Testing gas Supply Piping system Installing Remote Receiver UnitPressure Testing Heater Gas Connections Checking GAS ConnectionsInstalling Logs CGD3924NRA Installing Wireless Remote Control AccessoryInstalling 9-Volt Battery in Receiver Installing Crossover Log #4 Installing Logs CCL3924NR and CCL3930NROperating Heater For Your Safety Read Before LightingLighting Instructions Unvented Natural GAS LOG Heater Operating Manual Lighting ProcedureTo Turn OFF GAS To Appliance Optional Remote OperationPilot Flame Pattern Inspecting BurnersMain Burner Cghrcta Series OperationService Hints Unvented Natural GAS LOG Heater Cleaning and MaintenanceTechnical Service Cleaning Burner Injector Holder and Pilot AIR Inlet HoleObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Unvented Natural GAS LOG Heater TroubleshootingGas leak. See Warning statement at CGD3924NRA Unvented Natural GAS LOG Heater Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListCCL3924NR CCL3930NR KEY CCL3924NR CCL3930NR Part Number Description QTY Parts not Under Warranty Parts Under WarrantySpecifications AccessoriesWiring Diagram Warranty Information

CCL3924NR, CCL3930NR specifications

The Desa CCL3930NR and CCL3924NR are advanced heating solutions known for their efficiency and innovative features. These models stand out in the market due to their commitment to both performance and user convenience.

One of the defining characteristics of both models is their energy efficiency. They utilize cutting-edge technology that optimizes fuel consumption while delivering robust heating output. The CCL3930NR, in particular, is designed for larger spaces, providing up to 30,000 BTUs, making it an excellent choice for garages, workshops, or any sizable area requiring reliable warmth. On the other hand, the CCL3924NR is geared toward medium-sized spaces, offering a maximum of 24,000 BTUs, making it suitable for residential settings or smaller commercial environments.

Both units feature a user-friendly thermostat that enables easy temperature control, contributing to user comfort and convenience. This digital thermostat allows for precise temperature settings, ensuring the environment remains consistent and cozy. The programmable features also provide flexibility, allowing users to set schedules according to their needs.

Another significant aspect of these models is their safety technologies. Equipped with robust safety mechanisms, both the CCL3930NR and the CCL3924NR automatically shut off in case of overheating or if the flame goes out unexpectedly. This ensures peace of mind for users, especially in settings where safety is paramount.

The construction of these heaters reflects durability and intention. They are built with high-quality materials designed to withstand the test of time, ensuring longevity and consistent performance. The sleek design also offers aesthetic appeal, allowing them to fit seamlessly into various environments.

In terms of fuel types, both models are versatile, accommodating a variety of fuels such as propane and kerosene, making them adaptable to different user preferences and availability of fuel sources. This flexibility is further enhanced by the portability of the units, enabling easy relocation as spaces or heating needs change.

In conclusion, the Desa CCL3930NR and CCL3924NR represent cutting-edge heating solutions that combine efficiency, safety, and user-friendly features. Whether for personal or professional use, these models offer an effective way to ensure comfort in various environments.