Desa CCL3924NR Operating Heater, For Your Safety Read Before Lighting, Lighting Instructions

Page 15

OWNER’S MANUAL

INSTALLATION

Continued

Pegs

6

Log #2

Front Log (#1)

Figure 31 - Installing Crossover Log (#6) (CCL3930NR Shown)

Holes

7

Crossover

Log (#6)

 

Middle

Pegs

Log (#2)

Figure 32 - Installing Crossover Log (#7) to Model CCL3930NR Only

OPERATING

HEATER

FOR YOUR SAFETY

READ BEFORE

LIGHTING

WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas sup- plier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been un- der water.

LIGHTING

INSTRUCTIONS

WARNING:

If fireplace has glass doors, never operate this heater with glass doors closed. If you oper- ate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Also if fireplace opening has vents at the bottom, you must open the vents before operating heater.

You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater.

NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell. Orange flame will also be present. Open damper or window to vent smell.Thiswillonlylastafewhours.

Note: Home owners generally prefer to operate their heater with the chimney damper closed. This will put all the heat into the room. However, there may be times you will desire the full flames of the Hi heat setting but will find the heat output excessive. You can open the chimney damper (if you have one) fully or partially to release some of the heat.

WARNING: Damper handle will be hot if heater has been running.

1.STOP! Read the safety information in columns 1 and 2.

2.Make sure equipment shutoff valve is fully open.

3.Set selector switch in the OFF position.

WARNING: Burners will come on automatically within one minute when the remote selector switch is in the ON position after the pilot is lit.

4.Press in and turn control knob clock-

wise to the OFF position.

5.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety in- formation, columns 1 and 2. If you don’t smell gas, go to the next step.

injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will

settle on the floor.

 

Flame Adjustment Knob

 

Control Knob

 

IH

 

 

 

REMOTE

 

O

 

OFF

 

 

 

F

 

ON

N

F

 

O

P

 

LO

 

LI

 

 

TO

Ignitor Button

Selector Switch in OFF Position

 

 

Figure 33 - Control Knob and Ignitor Button Location

 

Continued

107553

15

For more information, visit www.desatech.com

Image 15
Contents What to do if YOU Smell GAS Remote ReadyUnvented Natural GAS LOG Heater Safety Information Unpacking Safety InformationProduct Features Local CodesUnusually Tight Construction Unvented Natural GAS LOG Heater Remote Control AccessoriesAIR for Combustion and Ventilation Providing Adequate VentilationAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Minimum Fireplace Clearance to Combustible Materials InstallationCheck GAS Type LOG Sizing RequirementsMinimum Noncombustible Material Clearances Unvented Natural GAS LOG Heater InstallationDetermining Minimum Mantel Clearances Determining Minimum Mantel Clearances When Using a HoodMantel Clearances Floor ClearancesInstalling Damper Clamp Accessory for Vented Operation Installing Heater Base AssemblyInstallation Items Needed Attaching Flexible Gas Hose to Heater Connecting to GAS SupplyChecking GAS Connections Installing Remote Receiver UnitPressure Testing gas Supply Piping system Pressure Testing Heater Gas ConnectionsInstalling Wireless Remote Control Accessory Installing Logs CGD3924NRAInstalling 9-Volt Battery in Receiver Installing Crossover Log #4 Installing Logs CCL3924NR and CCL3930NRFor Your Safety Read Before Lighting Operating HeaterLighting Instructions Optional Remote Operation Manual Lighting ProcedureUnvented Natural GAS LOG Heater Operating To Turn OFF GAS To ApplianceCghrcta Series Operation Inspecting BurnersPilot Flame Pattern Main BurnerCleaning Burner Injector Holder and Pilot AIR Inlet Hole Unvented Natural GAS LOG Heater Cleaning and MaintenanceService Hints Technical ServiceObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Unvented Natural GAS LOG Heater TroubleshootingGas leak. See Warning statement at CGD3924NRA Unvented Natural GAS LOG Heater Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListCCL3924NR CCL3930NR KEY CCL3924NR CCL3930NR Part Number Description QTY Parts not Under Warranty Parts Under WarrantyAccessories SpecificationsWiring Diagram Warranty Information

CCL3924NR, CCL3930NR specifications

The Desa CCL3930NR and CCL3924NR are advanced heating solutions known for their efficiency and innovative features. These models stand out in the market due to their commitment to both performance and user convenience.

One of the defining characteristics of both models is their energy efficiency. They utilize cutting-edge technology that optimizes fuel consumption while delivering robust heating output. The CCL3930NR, in particular, is designed for larger spaces, providing up to 30,000 BTUs, making it an excellent choice for garages, workshops, or any sizable area requiring reliable warmth. On the other hand, the CCL3924NR is geared toward medium-sized spaces, offering a maximum of 24,000 BTUs, making it suitable for residential settings or smaller commercial environments.

Both units feature a user-friendly thermostat that enables easy temperature control, contributing to user comfort and convenience. This digital thermostat allows for precise temperature settings, ensuring the environment remains consistent and cozy. The programmable features also provide flexibility, allowing users to set schedules according to their needs.

Another significant aspect of these models is their safety technologies. Equipped with robust safety mechanisms, both the CCL3930NR and the CCL3924NR automatically shut off in case of overheating or if the flame goes out unexpectedly. This ensures peace of mind for users, especially in settings where safety is paramount.

The construction of these heaters reflects durability and intention. They are built with high-quality materials designed to withstand the test of time, ensuring longevity and consistent performance. The sleek design also offers aesthetic appeal, allowing them to fit seamlessly into various environments.

In terms of fuel types, both models are versatile, accommodating a variety of fuels such as propane and kerosene, making them adaptable to different user preferences and availability of fuel sources. This flexibility is further enhanced by the portability of the units, enabling easy relocation as spaces or heating needs change.

In conclusion, the Desa CCL3930NR and CCL3924NR represent cutting-edge heating solutions that combine efficiency, safety, and user-friendly features. Whether for personal or professional use, these models offer an effective way to ensure comfort in various environments.