WARRANTY INFORMATION

KEEP THIS WARRANTY

Model

Serial No.

Date Purchased

Always specify model and serial numbers when communicating with the factory.

We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.

LIMITED WARRANTY

COMFORT GLOW VENT-FREE NATURAL GAS LOG HEATERS

DESA International warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.

This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.

This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.

TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.

Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

For information about this warranty write:

INTERNATIONAL

2701 Industrial Drive

P.O. Box 90004

Bowling Green, KY 42102-9004

www.desatech.com

107553-01

107553 01

Rev. A

 

NOT A UPC

05/00

 

Image 28
Contents Remote Ready What to do if YOU Smell GASUnvented Natural GAS LOG Heater Safety Information Safety Information Product FeaturesLocal Codes UnpackingUnvented Natural GAS LOG Heater Remote Control Accessories AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Check GAS TypeLOG Sizing Requirements Minimum Fireplace Clearance to Combustible MaterialsUnvented Natural GAS LOG Heater Installation Minimum Noncombustible Material ClearancesDetermining Minimum Mantel Clearances When Using a Hood Mantel ClearancesFloor Clearances Determining Minimum Mantel ClearancesInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Connecting to GAS Supply Attaching Flexible Gas Hose to HeaterInstalling Remote Receiver Unit Pressure Testing gas Supply Piping systemPressure Testing Heater Gas Connections Checking GAS ConnectionsInstalling Logs CGD3924NRA Installing Wireless Remote Control AccessoryInstalling 9-Volt Battery in Receiver Installing Logs CCL3924NR and CCL3930NR Installing Crossover Log #4Operating Heater For Your Safety Read Before LightingLighting Instructions Manual Lighting Procedure Unvented Natural GAS LOG Heater OperatingTo Turn OFF GAS To Appliance Optional Remote OperationInspecting Burners Pilot Flame PatternMain Burner Cghrcta Series OperationUnvented Natural GAS LOG Heater Cleaning and Maintenance Service HintsTechnical Service Cleaning Burner Injector Holder and Pilot AIR Inlet HoleTroubleshooting Observed Problem Possible Cause RemedyUnvented Natural GAS LOG Heater Troubleshooting Maintenance,Gas leak. See Warning statement at Unvented Natural GAS LOG Heater Illustrated Parts Breakdown CGD3924NRAParts List KEY Part Number Description QTYCCL3924NR CCL3930NR KEY CCL3924NR CCL3930NR Part Number Description QTY Parts Under Warranty Parts not Under WarrantySpecifications AccessoriesWiring Diagram Warranty Information

CCL3924NR, CCL3930NR specifications

The Desa CCL3930NR and CCL3924NR are advanced heating solutions known for their efficiency and innovative features. These models stand out in the market due to their commitment to both performance and user convenience.

One of the defining characteristics of both models is their energy efficiency. They utilize cutting-edge technology that optimizes fuel consumption while delivering robust heating output. The CCL3930NR, in particular, is designed for larger spaces, providing up to 30,000 BTUs, making it an excellent choice for garages, workshops, or any sizable area requiring reliable warmth. On the other hand, the CCL3924NR is geared toward medium-sized spaces, offering a maximum of 24,000 BTUs, making it suitable for residential settings or smaller commercial environments.

Both units feature a user-friendly thermostat that enables easy temperature control, contributing to user comfort and convenience. This digital thermostat allows for precise temperature settings, ensuring the environment remains consistent and cozy. The programmable features also provide flexibility, allowing users to set schedules according to their needs.

Another significant aspect of these models is their safety technologies. Equipped with robust safety mechanisms, both the CCL3930NR and the CCL3924NR automatically shut off in case of overheating or if the flame goes out unexpectedly. This ensures peace of mind for users, especially in settings where safety is paramount.

The construction of these heaters reflects durability and intention. They are built with high-quality materials designed to withstand the test of time, ensuring longevity and consistent performance. The sleek design also offers aesthetic appeal, allowing them to fit seamlessly into various environments.

In terms of fuel types, both models are versatile, accommodating a variety of fuels such as propane and kerosene, making them adaptable to different user preferences and availability of fuel sources. This flexibility is further enhanced by the portability of the units, enabling easy relocation as spaces or heating needs change.

In conclusion, the Desa CCL3930NR and CCL3924NR represent cutting-edge heating solutions that combine efficiency, safety, and user-friendly features. Whether for personal or professional use, these models offer an effective way to ensure comfort in various environments.