Desa CCL3930NR, CCL3924NR Unvented Natural GAS LOG Heater Remote Control Accessories

Page 4

UNVENTED NATURAL GAS LOG HEATER

REMOTE CONTROL ACCESSORIES

There are two optional remote controls that can be purchased separately for this log heater:

hand-held ON/OFF remote

hand-held thermostat remote

See Accessories, page 27.

The hand-held thermostat may not be used where vented decorative listing is required.

AIR FOR COMBUSTION AND VENTILATION

WARNING: This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ven- tilation air. Read the following in- structions to insure proper fresh air for this and other fuel-burning appliances in your home.

Today’s homes are built more energy effi- cient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.

While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper com- bustion and ventilation.

Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide ad- equate fresh air for these appliances. This will insure proper venting of vented fuel- burning appliances.

PROVIDING ADEQUATE VENTILATION

The following are excerpts from National Fuel Gas Code, NFPA 54/ANS Z223.1, Sec- tion 5.3, Air for Combustion and Ventilation.

All spaces in homes fall into one of the three following ventilation classifications:

1.Unusually Tight Construction

2.Unconfined Space

3.Confined Space

The information on pages 4 through 6 will help you classify your space and provide adequate ventilation.

Unusually Tight Construction

The air that leaks around doors and win- dows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.

Unusually tight construction is de- fined as construction where:

a.walls and ceilings exposed to the outside atmosphere have a con- tinuous water vapor retarder with a rating of one perm (6 x 10-11kg per pa-sec-m2) or less with open- ings gasketed or sealed and

b.weather stripping has been added on openable windows and doors and

c.caulking or sealants are applied to areas such as joints around window and door frames, be- tween sole plates and floors, be- tween wall-ceiling joints, be- tween wall panels, at penetra- tions for plumbing, electrical, and gas lines, and at other openings.

If your home meets all of the three criteria above, you must provide ad- ditional fresh air. See Ventilation Air From Outdoors, page 6.

If your home does not meet all of the three criteria above, proceed to De- termining Fresh-Air Flow For Heater Location, page 5.

Confined Space and Unconfined Space

The National Fuel Gas Code, ANS Z2123.1 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggre- gate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are con- sidered a part of the unconfined space.

This heater shall not be installed in a con- fined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air.

*Adjoining rooms are communicating only if there are doorless passageways or ventila- tion grills between them.

For more information, visit www.desatech.com

4

107553

Image 4
Contents Remote Ready What to do if YOU Smell GASUnvented Natural GAS LOG Heater Safety Information Safety Information Product FeaturesLocal Codes UnpackingUnvented Natural GAS LOG Heater Remote Control Accessories AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Check GAS TypeLOG Sizing Requirements Minimum Fireplace Clearance to Combustible MaterialsUnvented Natural GAS LOG Heater Installation Minimum Noncombustible Material ClearancesDetermining Minimum Mantel Clearances When Using a Hood Mantel ClearancesFloor Clearances Determining Minimum Mantel ClearancesInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Connecting to GAS Supply Attaching Flexible Gas Hose to HeaterInstalling Remote Receiver Unit Pressure Testing gas Supply Piping systemPressure Testing Heater Gas Connections Checking GAS ConnectionsInstalling Logs CGD3924NRA Installing Wireless Remote Control AccessoryInstalling 9-Volt Battery in Receiver Installing Logs CCL3924NR and CCL3930NR Installing Crossover Log #4Operating Heater For Your Safety Read Before LightingLighting Instructions Manual Lighting Procedure Unvented Natural GAS LOG Heater OperatingTo Turn OFF GAS To Appliance Optional Remote OperationInspecting Burners Pilot Flame PatternMain Burner Cghrcta Series OperationUnvented Natural GAS LOG Heater Cleaning and Maintenance Service HintsTechnical Service Cleaning Burner Injector Holder and Pilot AIR Inlet HoleTroubleshooting Observed Problem Possible Cause RemedyUnvented Natural GAS LOG Heater Troubleshooting Maintenance,Gas leak. See Warning statement at Unvented Natural GAS LOG Heater Illustrated Parts Breakdown CGD3924NRAParts List KEY Part Number Description QTYCCL3924NR CCL3930NR KEY CCL3924NR CCL3930NR Part Number Description QTY Parts Under Warranty Parts not Under WarrantySpecifications AccessoriesWiring Diagram Warranty Information

CCL3924NR, CCL3930NR specifications

The Desa CCL3930NR and CCL3924NR are advanced heating solutions known for their efficiency and innovative features. These models stand out in the market due to their commitment to both performance and user convenience.

One of the defining characteristics of both models is their energy efficiency. They utilize cutting-edge technology that optimizes fuel consumption while delivering robust heating output. The CCL3930NR, in particular, is designed for larger spaces, providing up to 30,000 BTUs, making it an excellent choice for garages, workshops, or any sizable area requiring reliable warmth. On the other hand, the CCL3924NR is geared toward medium-sized spaces, offering a maximum of 24,000 BTUs, making it suitable for residential settings or smaller commercial environments.

Both units feature a user-friendly thermostat that enables easy temperature control, contributing to user comfort and convenience. This digital thermostat allows for precise temperature settings, ensuring the environment remains consistent and cozy. The programmable features also provide flexibility, allowing users to set schedules according to their needs.

Another significant aspect of these models is their safety technologies. Equipped with robust safety mechanisms, both the CCL3930NR and the CCL3924NR automatically shut off in case of overheating or if the flame goes out unexpectedly. This ensures peace of mind for users, especially in settings where safety is paramount.

The construction of these heaters reflects durability and intention. They are built with high-quality materials designed to withstand the test of time, ensuring longevity and consistent performance. The sleek design also offers aesthetic appeal, allowing them to fit seamlessly into various environments.

In terms of fuel types, both models are versatile, accommodating a variety of fuels such as propane and kerosene, making them adaptable to different user preferences and availability of fuel sources. This flexibility is further enhanced by the portability of the units, enabling easy relocation as spaces or heating needs change.

In conclusion, the Desa CCL3930NR and CCL3924NR represent cutting-edge heating solutions that combine efficiency, safety, and user-friendly features. Whether for personal or professional use, these models offer an effective way to ensure comfort in various environments.