SAFETY INFORMATION

Continued

PRODUCT IDENTIFICATION

4. If you smell gas

Shut off gas supply

Do not try to light any appliance

Do not touch any electrical switch; do not use any phone in

 

your building

• Immediately call your gas supplier from a neighbor’s phone.

 

Follow the gas supplier’s instructions

• If you cannot reach your gas supplier, call the fire department

5. Always run heater with plaque control knob at the 1, 2, 3, or 4

locked positions. Never set control knob between locked positions.

Poor combustion and higher levels of carbon monoxide may result.

6. This heater needs fresh, outside air ventilation to run properly.

Ignitor Button

Control Knob

Grill Guard

 

This heater has an Oxygen Depletion Sensing (ODS) safety

 

shutoff system. The ODS shuts down the heater if not enough

 

fresh air is available. See Air for Combustion and Ventilation,

 

pages 4 through 6.

7.

If heater shuts off, do not relight until you provide fresh, out-

 

side air. If heater keeps shutting off, have it serviced.

8.

Do not run heater

 

where flammable liquids or vapors are used or stored

 

under dusty conditions

9.

Do not use heater if any part has been under water. Immedi-

 

ately call a qualified service technician to inspect the room

 

heater and to replace any part of the control system and any

 

gas control which has been under water.

10.

Turn off heater, unplug blower and let heater cool before ser-

 

vicing. Only a qualified service person should service and re-

 

pair heater.

11. Operating heater above elevations of 4,500 feet could cause

 

pilot outage.

12.

To prevent performance problems, do not use propane/LP fuel

 

tank of less than 100 lbs. capacity.

13.

Before using furniture polish, wax, carpet cleaner, or similar

 

products, turn heater off. If heated, the vapors from these prod-

 

ucts may create a white powder residue within burner box or

 

on adjacent walls or furniture.

14.

Provide adequate clearances around air openings.

Plaque

Heater

Cabinet

Front

Panel

Figure 1 - Vent-Free Gas Heater

UNPACKING

1.Remove heater from carton.

2.Remove all protective packaging applied to heater for shipment.

3.Check heater for any shipping damage. If heater is damaged, promptly inform dealer where you bought heater.

PRODUCT FEATURES

SAFETY DEVICE

This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent- free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.

LOCAL CODES

Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of National Fuel Gas Code, ANSI Z223.1/NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

PIEZO IGNITION SYSTEM

This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.

THERMOSTATIC HEAT CONTROL

(Thermostat Models Only)

Thermostat models have a thermostat sensing bulb and a control valve. This results in the greatest heater comfort. This can also result in lower gas bills.

For morevisit www..com

107887-01E

Image 3
Contents Safety Information and Installation Manual VP16IT, VN18IT VP22IT, VN25ITWhat to do if YOU Smell GAS Safety Information Table of ContentsLocal Codes Safety Information Product IdentificationProduct Features UnpackingConfined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Locating Heater InstallationInstallation Items Check GAS TypeThermostat Sensing Bulb Installing Heater to WallPlacing Heater On Mounting Bracket Attaching Mounting Bracket To WallMounting Base Feet to Heater Installing Bottom Mounting ScrewsMounting Base Feet to Floor Where required by local code Mounting Heater to FloorTypical Inlet Pipe Diameters Connecting to GAS SupplyPressure Testing Gas Supply Piping System Pressure Testing Heater Gas ConnectionsChecking GAS Connections NON-THERMOSTAT Models For Your Safety Read Before Lighting Operating HeaterLighting Instructions To Turn OFF GAS to Appliance Manual Lighting ProcedureThermostat Models For Your Safety Read Before Lighting To Select Heating LevelVP16T VP26T VN18T VN30T Burner Patterns, Models VP16IT, VN18IT, VP26IT, & VN30IT Thermostat OperationInspecting Heater Cleaning and MaintenanceVN25IT SpecificationsObserved Problem Possible Cause Remedy TroubleshootingAfter ODS/pilot lights, keep control Observed Problem Possible Cause Cabinet Body Illustrated Parts BreakdownVN30T Description QTY Parts ListCabinet Body VP16IT, VN18IT, VP22IT, VN25IT KEY Part Number VP16IT VN18IT VP22IT VN25IT Description QTY VP16, VN18, VP16T, VN18T, VP16IT, VN18IT Burner AssemblyVP16T VN18T VP16IT VN18IT Description QTY VP26, VN30, VP26T, VN30T, VP22IT, VN25IT VP26T VN30T VP22IT VN25IT Description QTY Service Publications Accessories Replacement PartsService Hints Technical ServiceOwners Registration Form Postage Required 107887-01E Warranty Information

VN18, VP16, VN18T, VN25IT, VP22IT specifications

Desa VN18, VN30T, VP16, VP26T, and VP16T are a series of innovative devices tailored to meet diverse needs in various applications, ranging from industrial to consumer markets. Each model embodies distinct features, technologies, and characteristics that enhance performance and usability.

The Desa VN18 is renowned for its compact structure and lightweight design, making it ideal for small-scale applications. It integrates a sophisticated energy-efficient system that minimizes power consumption while maximizing output. This model supports various connectivity options, ensuring seamless integration with existing systems. Additionally, the VN18 is equipped with an intuitive user interface that simplifies operation, making it accessible even for those with limited technical experience.

In contrast, the VN30T offers enhanced capabilities suitable for medium to large-scale operations. This model boasts an impressive processing power, enabling it to handle more complex tasks with ease. The VN30T features advanced cooling technologies that keep the unit operating optimally, even under heavy workloads. Furthermore, its durable construction ensures longevity and reliability, making it a preferred choice for industrial environments.

The VP16, designed with versatility in mind, excels in adaptability across multiple applications. It offers interchangeable components, allowing users to customize setup based on specific needs. The technology embedded within the VP16 includes smart sensors that provide real-time feedback, helping users to monitor performance and adjust settings accordingly. This level of adaptability makes the VP16 an invaluable asset in dynamic working conditions.

Next in the lineup is the VP26T, which stands out for its robust performance under demanding conditions. With a focus on safety features, this model includes multiple fail-safes and redundancy systems that ensure consistent operation, even in emergencies. The VP26T is designed for heavy-duty applications, featuring enhanced materials that resist wear and tear, thereby prolonging its lifespan.

Finally, the VP16T combines the best aspects of its predecessors while introducing new technological advancements. It utilizes cutting-edge automation technologies that enable remote control and monitoring, enhancing user convenience. The VP16T's power management system optimizes energy use based on operational demands, contributing to both cost savings and sustainability.

Overall, Desa VN18, VN30T, VP16, VP26T, and VP16T represent a forward-thinking approach to design and functionality, addressing the evolving needs of users across various sectors. With their unique features and robust technologies, these models are set to redefine standards in their respective categories.