Desa VN30T, VP22IT, VN25IT, VP26T installation manual VP16T VN18T VP16IT VN18IT Description QTY

Page 27

PARTS LIST

Burner Assembly Models VP16, VN18, VP16T, VN18T, VP16IT, VN18IT

27

PARTS LIST

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 30 of this manual.

KEY

PART NUMBER

 

 

 

 

 

 

NO.

VP16

VN18

VP16T

VN18T

VP16IT

VN18IT

DESCRIPTION

QTY.

 

 

 

 

 

 

 

 

 

1

110803-02

110803-03

110803-02

110803-03

110803-02

110803-03

ODS/Pilot

1

2

110186-01

110186-01

110186-01

110186-01

110186-01

110186-01

Thermocouple Kit

1

3

098200-03

098200-03

_____

_____

098200-04

098200-04

Control Valve Bracket

1

4

105051-02

105051-02

105051-01

105051-01

099387-11

099387-11

Pilot Tubing

1

5

099218-06

099218-06

099218-06

099218-06

099218-01

099218-01

Burner

1

6

098508-01

098508-01

_____

_____

098508-01

098508-01

Valve Retainer Nut

1

7

099056-01

099056-02

099056-01

099056-02

099056-01

099056-02

Injector - Plaque A

 

 

 

 

 

 

_____

_____

(Plaques B & C for IT models only)

1-3

8

099056-25

099056-24

099056-25

099056-24

Injector - Plaque B

1

9

103844-01

103844-01

_____

_____

100605-01

100605-01

Control Valve

1

10

107660-01

107660-01

_____

_____

107899-01

107899-01

Control Valve Tube (Inlet Tubing)

1

11

103352-03

103352-03

_____

_____

107892-02

107892-02

Tubing-Valve to Plaque A

1

12

103352-04

103352-04

_____

_____

107892-01

107892-01

Tubing-Valve to Plaque B

1

13

_____

_____

_____

_____

107892-03

107892-03

Tubing-Valve to Plaque C

1

14

_____

_____

_____

_____

_____

_____

Tubing-Valve to Plaque D

 

15

_____

_____

_____

_____

100615-01

100615-01

Male Connector

1

16

_____

_____

104818-03

104818-03

_____

_____

Outlet Tubing - Valve to Burner

1

 

 

 

 

 

 

 

 

 

For morevisit www..com

107887-01E

Image 27
Contents Safety Information and Installation Manual VP16IT, VN18IT VP22IT, VN25ITWhat to do if YOU Smell GAS Safety Information Table of ContentsLocal Codes Safety Information Product IdentificationProduct Features UnpackingConfined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Locating Heater InstallationInstallation Items Check GAS TypeThermostat Sensing Bulb Installing Heater to WallPlacing Heater On Mounting Bracket Attaching Mounting Bracket To WallMounting Base Feet to Heater Installing Bottom Mounting ScrewsMounting Base Feet to Floor Where required by local code Mounting Heater to FloorTypical Inlet Pipe Diameters Connecting to GAS SupplyPressure Testing Gas Supply Piping System Pressure Testing Heater Gas ConnectionsChecking GAS Connections NON-THERMOSTAT Models For Your Safety Read Before Lighting Operating HeaterLighting Instructions To Turn OFF GAS to Appliance Manual Lighting ProcedureThermostat Models For Your Safety Read Before Lighting To Select Heating LevelVP16T VP26T VN18T VN30T Burner Patterns, Models VP16IT, VN18IT, VP26IT, & VN30IT Thermostat OperationInspecting Heater Cleaning and MaintenanceVN25IT SpecificationsObserved Problem Possible Cause Remedy TroubleshootingAfter ODS/pilot lights, keep control Observed Problem Possible Cause Cabinet Body Illustrated Parts BreakdownVN30T Description QTY Parts ListCabinet Body VP16IT, VN18IT, VP22IT, VN25IT KEY Part Number VP16IT VN18IT VP22IT VN25IT Description QTY VP16, VN18, VP16T, VN18T, VP16IT, VN18IT Burner AssemblyVP16T VN18T VP16IT VN18IT Description QTY VP26, VN30, VP26T, VN30T, VP22IT, VN25IT VP26T VN30T VP22IT VN25IT Description QTY Service Publications Accessories Replacement PartsService Hints Technical ServiceOwners Registration Form Postage Required 107887-01E Warranty Information

VN18, VP16, VN18T, VN25IT, VP22IT specifications

Desa VN18, VN30T, VP16, VP26T, and VP16T are a series of innovative devices tailored to meet diverse needs in various applications, ranging from industrial to consumer markets. Each model embodies distinct features, technologies, and characteristics that enhance performance and usability.

The Desa VN18 is renowned for its compact structure and lightweight design, making it ideal for small-scale applications. It integrates a sophisticated energy-efficient system that minimizes power consumption while maximizing output. This model supports various connectivity options, ensuring seamless integration with existing systems. Additionally, the VN18 is equipped with an intuitive user interface that simplifies operation, making it accessible even for those with limited technical experience.

In contrast, the VN30T offers enhanced capabilities suitable for medium to large-scale operations. This model boasts an impressive processing power, enabling it to handle more complex tasks with ease. The VN30T features advanced cooling technologies that keep the unit operating optimally, even under heavy workloads. Furthermore, its durable construction ensures longevity and reliability, making it a preferred choice for industrial environments.

The VP16, designed with versatility in mind, excels in adaptability across multiple applications. It offers interchangeable components, allowing users to customize setup based on specific needs. The technology embedded within the VP16 includes smart sensors that provide real-time feedback, helping users to monitor performance and adjust settings accordingly. This level of adaptability makes the VP16 an invaluable asset in dynamic working conditions.

Next in the lineup is the VP26T, which stands out for its robust performance under demanding conditions. With a focus on safety features, this model includes multiple fail-safes and redundancy systems that ensure consistent operation, even in emergencies. The VP26T is designed for heavy-duty applications, featuring enhanced materials that resist wear and tear, thereby prolonging its lifespan.

Finally, the VP16T combines the best aspects of its predecessors while introducing new technological advancements. It utilizes cutting-edge automation technologies that enable remote control and monitoring, enhancing user convenience. The VP16T's power management system optimizes energy use based on operational demands, contributing to both cost savings and sustainability.

Overall, Desa VN18, VN30T, VP16, VP26T, and VP16T represent a forward-thinking approach to design and functionality, addressing the evolving needs of users across various sectors. With their unique features and robust technologies, these models are set to redefine standards in their respective categories.