Desa VP26, VN18, VN30T, VP16, VP22IT installation manual Safety Information and Installation Manual

Page 1

®

UNVENTED (VENT-FREE) INFRARED GAS HEATER

SAFETY INFORMATION AND INSTALLATION MANUAL

For..com

VN18, VN18T

VP16, VP16T

VP26, VP26T

VN30, VN30T

VP16IT, VN18IT

VP22IT, VN25IT

Model VN30 Shown

WARNING: If the information in this manual is not followed exactly, a fire or explosion may result caus- ing property damage, personal injury, or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s in- structions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a quali- fied installer, service agency, or the gas supplier.

WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For as- sistance or additional information consult a qualified installer, ser- vice agency, or the gas supplier.

WARNING: This is an unvented gas-fired heater. It uses air (oxy- gen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to Air for Combustion and Ventilation sec- tion on page 4 of this manual.

This appliance may be installed in an aftermarket*, permanently located, manufactured (mobile) home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

Save this manual for future.

Image 1
Contents VP16IT, VN18IT VP22IT, VN25IT Safety Information and Installation ManualWhat to do if YOU Smell GAS Safety Information Table of ContentsProduct Features Safety Information Product IdentificationUnpacking Local CodesProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Items InstallationCheck GAS Type Locating HeaterThermostat Sensing Bulb Installing Heater to WallPlacing Heater On Mounting Bracket Attaching Mounting Bracket To WallMounting Base Feet to Floor Where required by local code Installing Bottom Mounting ScrewsMounting Heater to Floor Mounting Base Feet to HeaterTypical Inlet Pipe Diameters Connecting to GAS SupplyPressure Testing Heater Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Operating Heater NON-THERMOSTAT Models For Your Safety Read Before LightingLighting Instructions Thermostat Models For Your Safety Read Before Lighting Manual Lighting ProcedureTo Select Heating Level To Turn OFF GAS to ApplianceVP16T VP26T VN18T VN30T Burner Patterns, Models VP16IT, VN18IT, VP26IT, & VN30IT Thermostat OperationInspecting Heater Cleaning and MaintenanceVN25IT SpecificationsObserved Problem Possible Cause Remedy TroubleshootingAfter ODS/pilot lights, keep control Observed Problem Possible Cause Cabinet Body Illustrated Parts BreakdownVN30T Description QTY Parts ListCabinet Body VP16IT, VN18IT, VP22IT, VN25IT KEY Part Number VP16IT VN18IT VP22IT VN25IT Description QTY VP16, VN18, VP16T, VN18T, VP16IT, VN18IT Burner AssemblyVP16T VN18T VP16IT VN18IT Description QTY VP26, VN30, VP26T, VN30T, VP22IT, VN25IT VP26T VN30T VP22IT VN25IT Description QTY Service Hints Replacement PartsTechnical Service Service Publications AccessoriesOwners Registration Form Postage Required 107887-01E Warranty Information

VN18, VP16, VN18T, VN25IT, VP22IT specifications

Desa VN18, VN30T, VP16, VP26T, and VP16T are a series of innovative devices tailored to meet diverse needs in various applications, ranging from industrial to consumer markets. Each model embodies distinct features, technologies, and characteristics that enhance performance and usability.

The Desa VN18 is renowned for its compact structure and lightweight design, making it ideal for small-scale applications. It integrates a sophisticated energy-efficient system that minimizes power consumption while maximizing output. This model supports various connectivity options, ensuring seamless integration with existing systems. Additionally, the VN18 is equipped with an intuitive user interface that simplifies operation, making it accessible even for those with limited technical experience.

In contrast, the VN30T offers enhanced capabilities suitable for medium to large-scale operations. This model boasts an impressive processing power, enabling it to handle more complex tasks with ease. The VN30T features advanced cooling technologies that keep the unit operating optimally, even under heavy workloads. Furthermore, its durable construction ensures longevity and reliability, making it a preferred choice for industrial environments.

The VP16, designed with versatility in mind, excels in adaptability across multiple applications. It offers interchangeable components, allowing users to customize setup based on specific needs. The technology embedded within the VP16 includes smart sensors that provide real-time feedback, helping users to monitor performance and adjust settings accordingly. This level of adaptability makes the VP16 an invaluable asset in dynamic working conditions.

Next in the lineup is the VP26T, which stands out for its robust performance under demanding conditions. With a focus on safety features, this model includes multiple fail-safes and redundancy systems that ensure consistent operation, even in emergencies. The VP26T is designed for heavy-duty applications, featuring enhanced materials that resist wear and tear, thereby prolonging its lifespan.

Finally, the VP16T combines the best aspects of its predecessors while introducing new technological advancements. It utilizes cutting-edge automation technologies that enable remote control and monitoring, enhancing user convenience. The VP16T's power management system optimizes energy use based on operational demands, contributing to both cost savings and sustainability.

Overall, Desa VN18, VN30T, VP16, VP26T, and VP16T represent a forward-thinking approach to design and functionality, addressing the evolving needs of users across various sectors. With their unique features and robust technologies, these models are set to redefine standards in their respective categories.