INSTALLATION

Thermostat Sensing Bulb Installing Heater To Wall

INSTALLATION

Continued

THERMOSTAT SENSING BULB

(Thermostat Models Only)

The thermostat sensing bulb has been placed inside the heater for protection during shipping.

Removing Front Panel Of Heater

1.Remove the four painted screws, two on each side of front panel.

2.Pull bottom of front panel forward, then out.

3.Remove any remaining packaging materials.

Locating Thermostat Sensing Bulb (for Thermostat Applications)

1.Remove front panel of heater (see Figure 7).

2.Locate thermostat sensing bulb just under burner assembly.

IMPORTANT: Attach thermostat sensing bulb to back of heater for proper operation.

Attaching Thermostat Sensing Bulb

1.Remove thermostat sensing bulb from holders inside heater. Route through slot opening in bottom of heater.

2.Place clamp on thermostat sensing bulb as shown in Figure 5. Clamp is provided in hardware package.

3.Snap clamp into upper mounting hole as shown in Figure 5. Mounting hole is located on lower left edge on back of heater. Make sure the thermostat sensing bulb is pointing up.

Thermostat Sensing Bulb

Clamp

Figure 5 - Attaching Thermostat Sensing Bulb

INSTALLING HEATER TO WALL

Mounting Bracket

Locate mounting bracket in heater carton. Remove mounting bracket from heater carton.

Figure 7 - Removing Front Panel Of Heater

Methods For Attaching Mounting Bracket To Wall

Only use last hole on each end of mounting bracket to attach bracket to wall. These two holes are 14 inches apart from their centers. Attach mounting bracket to wall in one of two ways:

1.Attaching to wall stud

2.Attaching to wall anchor

Attaching to Wall Stud: This method provides the strongest hold. Insert mounting screws through mounting bracket and into wall studs.

Attaching to Wall Anchor: This method allows you to attach mounting bracket to hollow walls (wall areas between studs) or to solid walls (concrete or masonry).

Decide which method better suits your needs. Either method will provide a secure hold for the mounting bracket.

Marking Screw Locations

1.Tape mounting bracket to wall where heater will be located. Make sure mounting bracket is level.

WARNING: Maintain minimum clearances shown in Figure 8, page 9. If you can, provide greater clear- ances from floor and joining wall.

Figure 6 - Mounting Bracket

For..com

107887-01E

Image 8
Contents What to do if YOU Smell GAS Safety Information and Installation ManualVP16IT, VN18IT VP22IT, VN25IT Table of Contents Safety InformationSafety Information Product Identification Product FeaturesUnpacking Local CodesAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installation Installation ItemsCheck GAS Type Locating HeaterInstalling Heater to Wall Thermostat Sensing BulbAttaching Mounting Bracket To Wall Placing Heater On Mounting BracketInstalling Bottom Mounting Screws Mounting Base Feet to Floor Where required by local codeMounting Heater to Floor Mounting Base Feet to HeaterConnecting to GAS Supply Typical Inlet Pipe DiametersChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connections Lighting Instructions NON-THERMOSTAT Models For Your Safety Read Before LightingOperating Heater Manual Lighting Procedure Thermostat Models For Your Safety Read Before LightingTo Select Heating Level To Turn OFF GAS to ApplianceVP16T VP26T VN18T VN30T Thermostat Operation Burner Patterns, Models VP16IT, VN18IT, VP26IT, & VN30ITCleaning and Maintenance Inspecting HeaterSpecifications VN25ITTroubleshooting Observed Problem Possible Cause RemedyAfter ODS/pilot lights, keep control Observed Problem Possible Cause Illustrated Parts Breakdown Cabinet BodyParts List VN30T Description QTYCabinet Body VP16IT, VN18IT, VP22IT, VN25IT KEY Part Number VP16IT VN18IT VP22IT VN25IT Description QTY Burner Assembly VP16, VN18, VP16T, VN18T, VP16IT, VN18ITVP16T VN18T VP16IT VN18IT Description QTY VP26, VN30, VP26T, VN30T, VP22IT, VN25IT VP26T VN30T VP22IT VN25IT Description QTY Replacement Parts Service HintsTechnical Service Service Publications AccessoriesOwners Registration Form Postage Required 107887-01E Warranty Information

VN18, VP16, VN18T, VN25IT, VP22IT specifications

Desa VN18, VN30T, VP16, VP26T, and VP16T are a series of innovative devices tailored to meet diverse needs in various applications, ranging from industrial to consumer markets. Each model embodies distinct features, technologies, and characteristics that enhance performance and usability.

The Desa VN18 is renowned for its compact structure and lightweight design, making it ideal for small-scale applications. It integrates a sophisticated energy-efficient system that minimizes power consumption while maximizing output. This model supports various connectivity options, ensuring seamless integration with existing systems. Additionally, the VN18 is equipped with an intuitive user interface that simplifies operation, making it accessible even for those with limited technical experience.

In contrast, the VN30T offers enhanced capabilities suitable for medium to large-scale operations. This model boasts an impressive processing power, enabling it to handle more complex tasks with ease. The VN30T features advanced cooling technologies that keep the unit operating optimally, even under heavy workloads. Furthermore, its durable construction ensures longevity and reliability, making it a preferred choice for industrial environments.

The VP16, designed with versatility in mind, excels in adaptability across multiple applications. It offers interchangeable components, allowing users to customize setup based on specific needs. The technology embedded within the VP16 includes smart sensors that provide real-time feedback, helping users to monitor performance and adjust settings accordingly. This level of adaptability makes the VP16 an invaluable asset in dynamic working conditions.

Next in the lineup is the VP26T, which stands out for its robust performance under demanding conditions. With a focus on safety features, this model includes multiple fail-safes and redundancy systems that ensure consistent operation, even in emergencies. The VP26T is designed for heavy-duty applications, featuring enhanced materials that resist wear and tear, thereby prolonging its lifespan.

Finally, the VP16T combines the best aspects of its predecessors while introducing new technological advancements. It utilizes cutting-edge automation technologies that enable remote control and monitoring, enhancing user convenience. The VP16T's power management system optimizes energy use based on operational demands, contributing to both cost savings and sustainability.

Overall, Desa VN18, VN30T, VP16, VP26T, and VP16T represent a forward-thinking approach to design and functionality, addressing the evolving needs of users across various sectors. With their unique features and robust technologies, these models are set to redefine standards in their respective categories.