Desa VP16T Replacement Parts, Service Hints, Technical Service, Service Publications Accessories

Page 30

30

REPLACEMENT PARTS SERVICE HINTS TECHNICAL SERVICE SERVICE PUBLICATIONS ACCESSORIES

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Technical Service Department at 1-866-672-6040.

When calling DESA International, have ready:

your name

your address

model and serial numbers of your heater

how heater was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the part to the factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International at 1-866-672-6040 for referral information.

When calling DESA International, have ready:

model number of your heater

the replacement part number

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burner will have delayed ignition

heater will not produce specified heat

propane/LP gas supply may be low (if used)

You may feel your gas pressure is too low. If so, contact your local natural or propane/LP gas supplier.

TECHNICAL SERVICE

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-866-672-6040. When calling please have your model and serial numbers of your heater ready.

You can also visit DESA International’s technical service web site at www.desatech.com.

SERVICE PUBLICATIONS

You can purchase a service manual from the address listed on the back page of this manual. Send a check for $5.00 payable to DESA International.

ACCESSORIES

Purchase these heater accessories from your local dealer. If they can not supply these accessories, call DESA International at 1-866-672-6040 for referral information. You can also write to the address listed on the back page of this manual.

EQUIPMENT SHUTOFF VALVE - GA5010

For all models. Equipment shutoff valve with 1/8" NPT tap.

FAN KITS - GA3250T

For all models. Provides better heat distribution. Makes heater more efficient. Complete installation and operating instructions included.

Thermostatically-controlled, blower turns itself on and off as re- quired.

For..com

107887-01E

Image 30
Contents Safety Information and Installation Manual VP16IT, VN18IT VP22IT, VN25ITWhat to do if YOU Smell GAS Table of Contents Safety InformationUnpacking Safety Information Product IdentificationProduct Features Local CodesUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Check GAS Type InstallationInstallation Items Locating HeaterInstalling Heater to Wall Thermostat Sensing BulbAttaching Mounting Bracket To Wall Placing Heater On Mounting BracketMounting Heater to Floor Installing Bottom Mounting ScrewsMounting Base Feet to Floor Where required by local code Mounting Base Feet to HeaterConnecting to GAS Supply Typical Inlet Pipe DiametersPressure Testing Gas Supply Piping System Pressure Testing Heater Gas ConnectionsChecking GAS Connections NON-THERMOSTAT Models For Your Safety Read Before Lighting Operating HeaterLighting Instructions To Select Heating Level Manual Lighting ProcedureThermostat Models For Your Safety Read Before Lighting To Turn OFF GAS to ApplianceVP16T VP26T VN18T VN30T Thermostat Operation Burner Patterns, Models VP16IT, VN18IT, VP26IT, & VN30ITCleaning and Maintenance Inspecting HeaterSpecifications VN25ITTroubleshooting Observed Problem Possible Cause RemedyAfter ODS/pilot lights, keep control Observed Problem Possible Cause Illustrated Parts Breakdown Cabinet BodyParts List VN30T Description QTYCabinet Body VP16IT, VN18IT, VP22IT, VN25IT KEY Part Number VP16IT VN18IT VP22IT VN25IT Description QTY Burner Assembly VP16, VN18, VP16T, VN18T, VP16IT, VN18ITVP16T VN18T VP16IT VN18IT Description QTY VP26, VN30, VP26T, VN30T, VP22IT, VN25IT VP26T VN30T VP22IT VN25IT Description QTY Technical Service Replacement PartsService Hints Service Publications AccessoriesOwners Registration Form Postage Required 107887-01E Warranty Information

VN18, VP16, VN18T, VN25IT, VP22IT specifications

Desa VN18, VN30T, VP16, VP26T, and VP16T are a series of innovative devices tailored to meet diverse needs in various applications, ranging from industrial to consumer markets. Each model embodies distinct features, technologies, and characteristics that enhance performance and usability.

The Desa VN18 is renowned for its compact structure and lightweight design, making it ideal for small-scale applications. It integrates a sophisticated energy-efficient system that minimizes power consumption while maximizing output. This model supports various connectivity options, ensuring seamless integration with existing systems. Additionally, the VN18 is equipped with an intuitive user interface that simplifies operation, making it accessible even for those with limited technical experience.

In contrast, the VN30T offers enhanced capabilities suitable for medium to large-scale operations. This model boasts an impressive processing power, enabling it to handle more complex tasks with ease. The VN30T features advanced cooling technologies that keep the unit operating optimally, even under heavy workloads. Furthermore, its durable construction ensures longevity and reliability, making it a preferred choice for industrial environments.

The VP16, designed with versatility in mind, excels in adaptability across multiple applications. It offers interchangeable components, allowing users to customize setup based on specific needs. The technology embedded within the VP16 includes smart sensors that provide real-time feedback, helping users to monitor performance and adjust settings accordingly. This level of adaptability makes the VP16 an invaluable asset in dynamic working conditions.

Next in the lineup is the VP26T, which stands out for its robust performance under demanding conditions. With a focus on safety features, this model includes multiple fail-safes and redundancy systems that ensure consistent operation, even in emergencies. The VP26T is designed for heavy-duty applications, featuring enhanced materials that resist wear and tear, thereby prolonging its lifespan.

Finally, the VP16T combines the best aspects of its predecessors while introducing new technological advancements. It utilizes cutting-edge automation technologies that enable remote control and monitoring, enhancing user convenience. The VP16T's power management system optimizes energy use based on operational demands, contributing to both cost savings and sustainability.

Overall, Desa VN18, VN30T, VP16, VP26T, and VP16T represent a forward-thinking approach to design and functionality, addressing the evolving needs of users across various sectors. With their unique features and robust technologies, these models are set to redefine standards in their respective categories.