Desa VN18, VP26, VN30T Attaching Mounting Bracket To Wall, Placing Heater On Mounting Bracket

Page 9

INSTALLATION

Continued

2.Mark screw locations on wall (see Figure 8).

Note: Only mark last hole on each end of mounting bracket. Insert mounting screws through these holes only.

3.Remove tape and mounting bracket from wall.

16"

14"

Min.

 

WallAdjoining

Only Insert Mounting

25 3/4"

Optional

 

Screws Through Last

19 3/4"

 

Hole On Each End

 

 

 

Min.

 

Floor

 

 

4 and 5 Plaque Heaters

 

12"

14"

 

 

Min.

 

 

AdjoiningWall

Only Insert Mounting

25 3/4"

Optional

Screws Through Last

19 3/4"

 

Hole On Each End

 

 

Min.

Floor

3 Plaque Heater

Figure 8 - Mounting Bracket Clearances

Attaching Mounting Bracket To Wall

Note: Wall anchors, mounting screws, and spacers are in hardware package. The hardware package is provided with heater.

Attaching To Wall Stud Method

For attaching mounting bracket to wall studs

1. Drill holes at marked locations using 9/64" drill bit.

2. Place mounting bracket onto wall. Line up last hole on each end of bracket with holes drilled in wall.

3. Insert mounting screws through bracket and into wall studs.

4. Tighten screws until mounting bracket is firmly fastened to wall studs.

INSTALLATION

9

Installing Heater To Wall (Cont.)

 

 

Attaching To Wall Anchor Method

For attaching mounting bracket to hollow walls (wall areas between studs) or solid walls (concrete or masonry)

1.Drill holes at marked locations using 5/16" drill bit. For solid walls (concrete or masonry), drill at least 1" deep.

2.Fold wall anchor as shown in Figure 9.

3.Insert wall anchor (wings first) into hole. Tap anchor flush to wall.

4.For thin walls (1/2" or less), insert red key into wall anchor. Push red key to “pop” open anchor wings.

IMPORTANT: Do not hammer key!

For thick walls (over 1/2" thick) or solid walls, do not pop open wings.

5.Place mounting bracket onto wall. Line up last hole on each end of bracket with wall anchors.

6.Insert mounting screws through bracket and into wall anchors.

7.Tighten screws until mounting bracket is firmly fastened to wall.

Figure 9 - Folding Anchor

Figure 10 - Popping Open

 

Anchor Wings For Thin Walls

Placing Heater On Mounting Bracket

1.Locate two horizontal slots on back panel of heater.

2.Place heater onto mounting bracket. Slide horizontal slots onto stand-out tabs on mounting bracket.

Horizontal Slots

Stand-Out Tab

 

Mounting Bracket

 

 

(attached to wall)

 

 

 

 

 

Figure 11 - Mounting Heater Onto Mounting Bracket

For morevisit www..com

107887-01E

Image 9
Contents Safety Information and Installation Manual VP16IT, VN18IT VP22IT, VN25ITWhat to do if YOU Smell GAS Safety Information Table of ContentsProduct Features Safety Information Product IdentificationUnpacking Local CodesProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Items InstallationCheck GAS Type Locating HeaterThermostat Sensing Bulb Installing Heater to WallPlacing Heater On Mounting Bracket Attaching Mounting Bracket To WallMounting Base Feet to Floor Where required by local code Installing Bottom Mounting ScrewsMounting Heater to Floor Mounting Base Feet to HeaterTypical Inlet Pipe Diameters Connecting to GAS SupplyPressure Testing Gas Supply Piping System Pressure Testing Heater Gas ConnectionsChecking GAS Connections NON-THERMOSTAT Models For Your Safety Read Before Lighting Operating HeaterLighting Instructions Thermostat Models For Your Safety Read Before Lighting Manual Lighting ProcedureTo Select Heating Level To Turn OFF GAS to ApplianceVP16T VP26T VN18T VN30T Burner Patterns, Models VP16IT, VN18IT, VP26IT, & VN30IT Thermostat OperationInspecting Heater Cleaning and MaintenanceVN25IT SpecificationsObserved Problem Possible Cause Remedy TroubleshootingAfter ODS/pilot lights, keep control Observed Problem Possible Cause Cabinet Body Illustrated Parts BreakdownVN30T Description QTY Parts ListCabinet Body VP16IT, VN18IT, VP22IT, VN25IT KEY Part Number VP16IT VN18IT VP22IT VN25IT Description QTY VP16, VN18, VP16T, VN18T, VP16IT, VN18IT Burner AssemblyVP16T VN18T VP16IT VN18IT Description QTY VP26, VN30, VP26T, VN30T, VP22IT, VN25IT VP26T VN30T VP22IT VN25IT Description QTY Service Hints Replacement PartsTechnical Service Service Publications AccessoriesOwners Registration Form Postage Required 107887-01E Warranty Information

VN18, VP16, VN18T, VN25IT, VP22IT specifications

Desa VN18, VN30T, VP16, VP26T, and VP16T are a series of innovative devices tailored to meet diverse needs in various applications, ranging from industrial to consumer markets. Each model embodies distinct features, technologies, and characteristics that enhance performance and usability.

The Desa VN18 is renowned for its compact structure and lightweight design, making it ideal for small-scale applications. It integrates a sophisticated energy-efficient system that minimizes power consumption while maximizing output. This model supports various connectivity options, ensuring seamless integration with existing systems. Additionally, the VN18 is equipped with an intuitive user interface that simplifies operation, making it accessible even for those with limited technical experience.

In contrast, the VN30T offers enhanced capabilities suitable for medium to large-scale operations. This model boasts an impressive processing power, enabling it to handle more complex tasks with ease. The VN30T features advanced cooling technologies that keep the unit operating optimally, even under heavy workloads. Furthermore, its durable construction ensures longevity and reliability, making it a preferred choice for industrial environments.

The VP16, designed with versatility in mind, excels in adaptability across multiple applications. It offers interchangeable components, allowing users to customize setup based on specific needs. The technology embedded within the VP16 includes smart sensors that provide real-time feedback, helping users to monitor performance and adjust settings accordingly. This level of adaptability makes the VP16 an invaluable asset in dynamic working conditions.

Next in the lineup is the VP26T, which stands out for its robust performance under demanding conditions. With a focus on safety features, this model includes multiple fail-safes and redundancy systems that ensure consistent operation, even in emergencies. The VP26T is designed for heavy-duty applications, featuring enhanced materials that resist wear and tear, thereby prolonging its lifespan.

Finally, the VP16T combines the best aspects of its predecessors while introducing new technological advancements. It utilizes cutting-edge automation technologies that enable remote control and monitoring, enhancing user convenience. The VP16T's power management system optimizes energy use based on operational demands, contributing to both cost savings and sustainability.

Overall, Desa VN18, VN30T, VP16, VP26T, and VP16T represent a forward-thinking approach to design and functionality, addressing the evolving needs of users across various sectors. With their unique features and robust technologies, these models are set to redefine standards in their respective categories.