TROUBLESHOOTING
Continued
WARNING: If you smell gas
•Shut off gas supply.
•Do not try to light any appliance.
•Do not touch any electrical switch; do not use any phone in your building.
•Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions.
•If you cannot reach your gas supplier, call the fire department.
IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These
OBSERVED PROBLEM | POSSIBLE CAUSE | REMEDY | |||
|
|
|
|
|
|
Heater produces a clicking/tick- | 1. | Metal expanding while heating | 1. | This is common with most heat- | |
ing noise just after burner is lit or |
| or contracting while cooling |
| ers. If noise is excessive, contact | |
shut off |
|
|
| qualified service person | |
|
|
|
|
|
|
Heater produces unwanted odors | 1. | Heater burning vapors from | 1. | Open window and ventilate | |
|
| paint, hair spray, glues, clean- |
| room. Stop using odor causing | |
|
| ers, chemicals, new carpet, |
| products while heater is running | |
|
| etc. (See IMPORTANT state- |
|
|
|
|
| ment above) |
|
|
|
| 2. | Gas leak. See Warning | 2. | Locate and correct all leaks | |
|
| statement above |
| (see Checking Gas Connec- | |
|
|
|
| tions, page 15) | |
|
|
|
|
|
|
Heater shuts off in use (ODS | 1. | Not enough fresh air is | 1. | Open window and/or door for | |
operates) |
| available |
| ventilation | |
| 2. | Low line pressure | 2. | Contact local natural or pro- | |
|
|
|
| pane/LP gas company | |
| 3. | ODS/pilot is partially | 3. | Clean ODS/pilot (see Cleaning | |
|
| clogged |
| and Maintenance, page 23) | |
|
|
|
|
|
|
Gas odor even when control knob | 1. | Gas leak. See Warning | 1. | Locate and correct all leaks | |
is in OFF position |
| statement above |
| (see Checking Gas Connec- | |
| 2. | Control valve defective |
| tions, page 15) | |
| 2. | Replace control valve | |||
|
|
|
|
|
|
Gas odor during combustion | 1. | Foreign matter between con- | 1. | Take apart gas tubing and | |
|
| trol valve and burner |
| remove foreign matter | |
| 2. | Gas leak. See Warning | 2. | Locate and correct all leaks | |
|
| statement above |
| (see Checking Gas Connec- | |
|
|
|
| tions, page 15) |
www.desatech.com | 27 |