INSTALLATION
Continued
3.Check all joints from propane/LP supply tank to equipment shutoff valve for propane/LP gas (see Figure 16) or from gas meter to equipment shutoff valve for natural gas (see Figure 17). Apply noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak.
4.Correct all leaks at once.
Equipment | Open | |
| ||
Shutoff Valve |
| |
| Closed | |
Figure 15 - Equipment Shutoff Valve | ||
Equipment | Propane/LP Tank | |
Shutoff Valve | ||
|
Valve Location
Figure 16 - Checking Gas Joints
Equipment
Shutoff Valve
Gas Meter
Valve Location
INSTALLING OPTIONAL REMOTE ACCESSORIES
Installing Remote Receiver Remote control accessories are available sepa- rately (see Accessories, page 29).
1.If unit is already installed in fireplace, continue with these instructions. If unit has not been installed in fireplace, go to step 6 and continue installation of remote accessory.
WARNING: Turn off heater and let cool before handling any part of heater. Make sure gas is turned of to unit.
2.Carefully remove logs and set aside.
3.Locate mounting screws on sides of heater base assembly and remove screws. Set screws aside for reinstallation.
4.Disconnect gas line from heater base as shown in Figure 11, page 13.
WARNING: A qualified ser- vice person must connect and disconnect gas to heater. Follow all local codes.
5.Remove heater base from fireplace.
6.Install receiver bracket to base with phillips screws provided in hardware kit as shown in Figure 18.
7.Disconnect jumper wire from control valve at TPTH and TH locations (see Figure 19).
Remote
Receiver
Bracket
Phillips Screws
Figure 18 - Installing Remote Receiver Bracket
Figure 17 - Checking Gas Joints
Jumper
Wire
Control Valve
Figure 19 - Disconnecting Jumper Wire from Control Valve
16 | www.desatech.com |