Desa VGL24NRA, VGL24PRA, VGL18PRA Installing Optional Remote Accessories, Equipment Shutoff Valve

Page 16

INSTALLATION

Continued

3.Check all joints from propane/LP supply tank to equipment shutoff valve for propane/LP gas (see Figure 16) or from gas meter to equipment shutoff valve for natural gas (see Figure 17). Apply noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak.

4.Correct all leaks at once.

Equipment

Open

 

Shutoff Valve

 

 

Closed

Figure 15 - Equipment Shutoff Valve

Equipment

Propane/LP Tank

Shutoff Valve

 

Valve Location

Figure 16 - Checking Gas Joints

Equipment

Shutoff Valve

Gas Meter

Valve Location

INSTALLING OPTIONAL REMOTE ACCESSORIES

Installing Remote Receiver Remote control accessories are available sepa- rately (see Accessories, page 29).

1.If unit is already installed in fireplace, continue with these instructions. If unit has not been installed in fireplace, go to step 6 and continue installation of remote accessory.

WARNING: Turn off heater and let cool before handling any part of heater. Make sure gas is turned of to unit.

2.Carefully remove logs and set aside.

3.Locate mounting screws on sides of heater base assembly and remove screws. Set screws aside for reinstallation.

4.Disconnect gas line from heater base as shown in Figure 11, page 13.

WARNING: A qualified ser- vice person must connect and disconnect gas to heater. Follow all local codes.

5.Remove heater base from fireplace.

6.Install receiver bracket to base with phillips screws provided in hardware kit as shown in Figure 18.

7.Disconnect jumper wire from control valve at TPTH and TH locations (see Figure 19).

Remote

Receiver

Bracket

Phillips Screws

Figure 18 - Installing Remote Receiver Bracket

Figure 17 - Checking Gas Joints

Jumper

Wire

Control Valve

Figure 19 - Disconnecting Jumper Wire from Control Valve

16

www.desatech.com

112882-01B

Image 16
Contents What to do if YOU Smell GAS Table of Contents Safety Information Safety Information Product Features Remote Control AccessoriesProduct Identification Local CodesAIR for Combustion Ventilation Providing Adequate VentilationDetermining FRESH-AIR Flow for Fireplace Location Unusually Tight ConstructionVentilation AIR AIR for Combustion VentilatioinVentilation Air From Inside Building Installation Ventilation Air From OutdoorsCheck GAS Type Log Size Side Wall CeilingMinimum Firebox Size LogMantel Clearances Determining Minimum Mantel Clearances When Using a HoodMinimum Noncombustible Material Clearances Minimum Mantel Clearances Without Using Hood Installing Damper Clamp Accessory for Vented Operation Floor Clearances Installing Heater Base Assembly Installation Items NeededConnecting to GAS Supply External Regulator With Vent Pointing DownTest Pressures In Excess Of 1/2 Psig 3.5 kPa Checking GAS ConnectionsTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Installing Optional Remote Accessories Equipment Shutoff ValveConnecting Wires Installing Logs Log #1Operating Heater For Your Safety Read Before LightingLighting Instructions Manual Lighting Procedure To Turn OFF GAS To ApplianceOptional HAND-HELD Remote Operation Thermostat Series ModelGhrctb ON/OFF Series Model GhrcbAuto Shutoff Feature Inspecting BurnersPilot Flame Pattern Main BurnerBurner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceLogs Troubleshooting Observed Problem Possible Cause RemedySee Cleaning and Mainte Moisture/condensation noticed Gas leak. See Warning Statement aboveWiring Diagram Replacement PartsService Hints Technical ServiceCleaning KIT CCK Receiver and HAND-HELD Remote Control KIT Ghrcb SeriesInformation Video Equipment Shutoff Valve GA5010Illustrated Parts Breakdown Parts List Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS LOG Heaters