Graco 24B591, 24B596 important safety instructions Typical Installation

Models: 24B591 24B596

1 36
Download 36 pages 32.94 Kb
Page 5
Image 5

Installation

Installation

Typical Installation

The installation shown in FIG. 2 is only a guide for selecting and installing system components. Contact your Graco distributor for assistance in planning a system to suit your needs.

K E

!

H

Controller Capabilities

J

B2

C

B1 B3

A

D

G F

Low Reservoir Level switch (user provided)

Pressure or Cycle Switch for system control (user provided

Machine Counts for

System Control (user provided)

Pressure Switch or Cycle

Switch Alarm

Low Level Alarm

Remote Alarm Device

(Light or Horn) (user provided)

FIG. 2

A

Main Air Supply

G

Injector Banks

 

B

Filter/Regulator/Lubricator Assembly

H

Lubrication Controller

 

B1

- Filter

J

Model 24B591

12/24VDC Power Supply

 

B2

- Regulator

K

Model 24B596

115/230VAC Power Supply

 

B3

- Lubricator

 

 

 

CAir Solenoid Valve

DPump Module

EIgnition Switch

FHigh-Pressure Lubricant Supply Lines

313855H

5

Page 5
Image 5