Installation
Installation
Typical Installation
The installation shown in FIG. 2 is only a guide for selecting and installing system components. Contact your Graco distributor for assistance in planning a system to suit your needs.
K E
!
H
Controller Capabilities
J
B2
C
B1 B3
A
D
G F
Low Reservoir Level switch (user provided)
Pressure or Cycle Switch for system control (user provided
Machine Counts for
System Control (user provided)
Pressure Switch or Cycle
Switch Alarm
Low Level Alarm
Remote Alarm Device
(Light or Horn) (user provided)
FIG. 2
A | Main Air Supply | G | Injector Banks |
| |
B | Filter/Regulator/Lubricator Assembly | H | Lubrication Controller | ||
| B1 | - Filter | J | Model 24B591 | 12/24VDC Power Supply |
| B2 | - Regulator | K | Model 24B596 | 115/230VAC Power Supply |
| B3 | - Lubricator |
|
|
|
CAir Solenoid Valve
DPump Module
EIgnition Switch
F
313855H | 5 |