Technical Data

Technical Data

Input Contact

 

 

 

Power Source DC - model 24B591

9 - 30 VDC

 

 

Power Source AC - model 24B596

100 VAC to 240 VAC - 50/60 Hz

 

 

Power consumption

24 Watts

 

 

Cycle Pressure Control Input (optional)

Normally open pressure or cycle switch

 

 

Machine Count Control Input (optional)

Machine count control switch

 

 

Lubrication level (optional)

Normally open level switch, closes upon low level

 

 

Remote Manual Run Input

Normally open remote manual run switch

 

 

Outputs

 

 

 

Pump control

Pump Control Voltage = Power Source

 

 

Voltage

Power Source

 

 

Max Switching Voltage

250 VAC, 100 VDC

 

 

Max Switching Current

10 A (AC), 5A (DC)

 

 

Minimum Switching Capacity

100 mA @ 5 VDC

 

 

Low Level Alarm, normally open (optional)

 

 

 

Voltage

Power Source

 

 

Max Switching Voltage

250 VAC, 30 VDC

 

 

Max Switching Current

5A (AC), 5A (DC)

 

 

Minimum Switching Capacity

100 mA @ 5 VDC

 

 

Auxiliary Alarm, normally open (optional)

 

 

 

Voltage

Power Source

 

 

Max Switching Voltage

250 VAC, 30 VDC

 

 

Max Switching Current

5A (AC), 5A (DC)

 

 

Minimum Switching Capacity

100 mA @5 VDC

 

 

Status OK, normally open (optional)

Voltage-free Contact

 

 

Voltage

Power Source

 

 

Max Switching Voltage

250 VAC, 100 VDC

 

 

Max Switching Current

10 A (AC), 5A (DC)

 

 

Minimum Switching Capacity

100 mA @ 5 VDC

 

 

Protection grade

IP69K

 

 

Enclosure Material

Fiberglass reinforced polyester

 

 

Membrane Material

Polyester

 

 

Bushing

Ethylene Propylene Diene Monemer Rubber (EDPM)

 

 

Operating temperature range

- 40°F to 145°F (- 40°C to 63°C)

 

 

Storage Temperature

- 13°F to 145°F (- 25°C to 63°C)

 

 

34

313855H

Page 34
Image 34
Graco 24B596, 24B591 important safety instructions Technical Data, IP69K